Enviro C-11290, C-10381 owner manual Over 18/12 to 20/12 Over 20/12 to 21/12

Page 23
1
1.5
2
2.5
3.25
4
5
6
7
Flat to 7/12
Over 7/12 to 8/12 Over 8/12 to 9/12 Over 9/12 to 10/12 Over 10/12 to 11/12 Over 11/12 to 12/12 Over 12/12 to 14/12 Over 14/12 to 16/12 Over 16/12 to 18/12
Feet
Meters
Minimum Height
Roof Pitch
Table 6: Minimum ‘H’ for Figure 32.
0.3
0.46
0.61
0.76
0.99
1.22
1.52
1.83
2.13

Initial Installation

QUALIFIED INSTALLERS ONLY

the support straps that extend out beyond the edge of the flashing.

7.Slip the flashing over the pipe section protruding through the roof. Secure the base of the flashing to the roof with roofing nails. Use a non-hardening sealant between the uphill edge of the flashing and the roof. Insure the roofing material overlaps the top edge of the flashing as shown in Figure 30. Verify that you have at least the minimum clearance to combustibles at the roof line.

8.Continue to add pipe sections until the height of the vent cap meets the minimum code requirements. Refer to Figure 32 and Table 6. Note that for steep roof pitches, the vent height must be increased. In high wind conditions, nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors can result in poor draft, or down drafting. In these cases, increasing the vent height may solve the problem.

9.Slip the storm collar over the pipe, and push it down to the top of the roof flashing as shown in Figure 31. Use the non-hardening sealant around the joint between the pipe and the storm collar.

10. Twist-lock the vent cap.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 32: Height of Vertical Termination;

 

 

 

 

Reference Table 6.

 

Over 18/12 to 20/12

7.5

2.29

 

 

 

 

 

NOTES:

 

Over 20/12 to 21/12

8

2.44

 

 

 

 

 

 

 

 

(a)If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (91 cm), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (see Figure 33).

(b)When ever possible, use 45° degree elbows instead of 90° degree elbows. The 45° degree elbow offers less restriction to the flow of flue gases and intake air.

(c)For multi story installations. A ceiling firestop is required at the second floor, and any subsequent floors (see Figure 34). The opening should be framed to 10” (25.4 cm) x 10” (25.4 cm) inside dimensions, in the same manner as shown in Figure 30.

(d)Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheet rocked with standard building materials. However consult the appliance manufactures installation instructions for the minimum allowable clearance between the outside of the vent pipe, and the combustible surfaces of the enclosure. Do not fill any required air spaces with insulation.

23

Image 23
Contents Consumer InstallerGeneral Safety PrecautionsTable of Contents Rear Vent DV Codes And ApprovalsTOP Vent DV Westport Exterior Dimensions SpecificationsMAY OperatingInstructionsPilot Flame Operating InstructionsComponent Sound & Reason Electronic Ignition Module Location Maintenance And ServiceHandles for Removing Door To ReplaceConversion Kit Installation Kit Parts ListRemove the black protection cap from Qualified Installers only Initial InstallationRound Support Vent Termination Restrictions KIT Components Installation InstructionsManufacturer Trade Name Nominal Sizes Installation of Fireplace Horizontal Vent Kit4DSC Shows the vent restrictor position required, relative to Twist-Lock Connection 51mm at top, 1½ 38mm at sides, 1½ 38mm at BottomTermination Pipe and elbows may be utilized in the attic, as Over 18/12 to 20/12 Over 20/12 to 21/12 Follow installation steps 1 & 2 under Initial Do not interfere with the structural integrity of the walls 33a-2002 Test Methods and the Resulting ITS Firebox Top Installation for Top Vented Horizontal Termination Corner InstallationA. Installations InstallationWiring Diagram Canadian InstallationsSpillage Test Venting of a Fireplace Fitted with the Drafthood AdaptorOptional Finishing Automatic Safety Shut DownSpill Switch Replacement To Test Valve Pressures GAS Line ConnectionWiring Diagram For Fan Control Wire Size Max. LengthOptional Blower Fan Installation Secondary InstallationComplete Log Placement Log Placement with Rock Wool Brick panel bracket, slots shown Problem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts List CastEGWP-505PG EGWP-501PG Parts Diagram Cast Parts List Components Parts List Components Parts Diagram Components To the Dealer WarrantyWarranty Installation Data Sheet