Maintenance And Service
Fuel Conversion:
TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
Please read and understand these instructions before installing.
Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
Kit Parts List:
1 - Orifice (NG - #39 DMS or LP - #53 DMS)
1 - Pilot Injector (NG 0.62 mm; LP 0.35 mm)
1 - Installation instruction sheet
1 - Conversion label
Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are missing, contact your dealer, distributor or courier company to have them replaced before starting this installation.
Conversion Kit Installation:
1.Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the
The gas supply must be shut off prior to
disconnecting the electrical power and | Rotate handles |
|
| |||||||
before proceeding | with | the | conversion. | and remove the |
| Pilot assembly moved | ||||
Allow the valve and unit to cool down to | door and glass. |
| from firebox for clarity. | |||||||
|
| |||||||||
room temperature. |
|
|
|
|
|
|
|
| ||
2. Remove | the | glass | as | shown | in | the |
|
|
| |
Maintenance | and Service | - | Glass | Door |
|
|
| |||
Removal. |
|
|
|
|
|
|
|
|
|
|
3. Carefully remove the log set and ember |
|
| Lift off the pilot | |||||||
material if they are installed. |
|
|
|
|
| head and replace | ||||
|
|
|
|
| with proper pilot | |||||
4. Remove | the | burner as | shown | in | the |
|
| |||
|
| orifice for fuel type | ||||||||
Maintenance and Service - Burner Removal. |
|
| to be used. | |||||||
5. Convert the burner orifice(s): |
|
|
|
|
|
| ||||
a) Remove the main burner orifice with a |
|
|
| |||||||
½ inch deep socket. |
|
|
|
|
|
|
| |||
b) Put a bead of |
|
|
| |||||||
approved | Teflon | tape | on | the | orifice | Using a ½" deep |
| Undo the two | ||
threads before installing into the brass |
| (2) screws that | ||||||||
socket remove/reinstall |
| |||||||||
elbow. |
|
|
|
|
|
|
| the main burner orifice. |
| hold burner in |
|
|
|
|
|
|
| Venturi adjustment | the firebox. | ||
c) Install the new orifice(s) from the kit |
|
| ||||||||
| bracket. |
| ||||||||
into the brass elbow. |
|
|
|
| Figure 8: Unit burner shown apart. | |||||
|
|
|
|
|
|
|
|
11