Hampton Direct H35-NG1, H35-LP1 installation manual Exterior Vent Terminal Locations

Page 10

10

Hampton® H35 Direct Vent Freestanding Gas Stove

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm)

C= Clearance to permanently closed window *(min. 12"/30cm)

D= Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal (min. 22"/55cm) check with local code.

E= Clearance to unventilated soffit (min. 12"/30cm)

F= Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura- Vent Termination Cap (min.12"/30cm), with Riser Vent (min. 6"/15cm)

G= Clearance to inside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura- Vent Termination Cap (min.12"/30cm), with Riser Vent (min. 6"/15cm)

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from the centerline of the regulator.

J= Clearance to service regulator vent outlet *(min. 36"/90cm)

K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance *(12"/30cm)

L= Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

M= **Clearance above paved sidewalk or a paved driveway located on public property *(min. 84"/2.1m)

N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)***

Note: * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

EXTERIOR VENT TERMINAL LOCATIONS

INSTALLATION

Image 10
Contents H35 Direct Vent Gas Fireplace Models H35-NG1 Natural Gas H35-LP1 PropaneHampton Unit DimensionsTo the New Owner Table of Contents Safety Label Copy of Safety LabelRequirements MA Code CO DetectorImportant Message Save These Instructions InstallationSpecifications Information for Mobile Manufactured Homes After First SaleClearances to Combustibles General Safety InformationInstallation Checklist This includesCombustion Locating YourGAS Stove Ventilation AIRPrecautions InstallationSafety Precautions For the Installer Exterior Vent Terminal Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsVertical Terminations Systems for Rotating 45O Elbow for Straight Horizontal TerminationsVenting Arrangements Venting SystemsDura-Vent Snorkel Termination Horizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalStraight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff Termination Caps Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Dura-Vent Basic Horizontal Kit #Below Grade Snorkel Installation DURA-VENT Horizontal InstallationsDiagram 1 Hint Apply silicone to female end Snorkel TerminationsDURA-VENT Vertical Termination Offset Chart This allows for small adjustmentsAppoved for US Installations Only Converting a Factory Built Metal ChimneyHigh Elevation Cathedral CeilingsGAS Connection But not overtightened Valve DescriptionClockwise to open Counter-clockwise to close Conversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Propane Conversion Kit 740-952 Contains Qty Conversion KIT to Lower BTU RatingNatural Gas Conversion Kit 740-950 Contains Qty Burner Orifi ce02-46 G LOG SET InstallationOptional Brick Panel 02-44 B 02-56 FLava rock Pins on Rear Log SupportPin Cutout Notch CutoutTop Tile Inset Double Door InstallationTile Inset Installation Side Tile InsetDoor Hinge Removal Remove screws Release catch by Pulling upWiring Diagrams InstructionsRemote Control Wall ThermostatOperating Instructions Copy of the Lighting Plate Instructions Adjusting Flame HeightAutomatic Convection FAN Operation Maintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances LOG Replacement General Vent MaintenanceFAN Maintenance Glass ReplacementRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue Replacing the FanParts List Main AssemblyBurner & LOG Assembly Brick Panel SETHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.