Hampton Direct H35-LP1, H35-NG1 Installation of the DC Sparker For the P90 Units Only

Page 29

INSTALLATION

7) Attach the Piezo ignition wire to the DC

11) Attach the DC sparker generator wires to

Sparker.

the DC sparker.

Piezo

Ignitor

Installation of the DC Sparker

for the P90 Units Only:

1)Locate the Piezo Ignitor situated at the side of valve.

Piezo

Ignitor

8)Insert both the ground wire and the DC sparker generator wire through the hole of the DC spark heat shield.

12)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

Battery

Compartment

2)Remove the Piezo Ignitor by unscrewing the nut at the back of the mounting bracket.

Ignitor

Wire

Piezo

Ignitor

9)Install the plastic bushing over the outside of the hole.

10)Attach the ground wire to the DC spark mounting bracket.

13)Attach the heat shield to the DC sparker, then mount this onto the stove.

Note: We recommend attaching the DC sparker box to the bottom rear of the stove (or place this in a convenient location, away from the heat source).

14)Tie up the loose wire with the wire clip.

3)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker.

DC

Sparker

Ignitor

Wire

4)Install the 3/4" nylon plug to cover up the hole on the mounting bracket.

Hampton® H35 Direct Vent Freestanding Gas Stove

29

Image 29
Contents Models H35-NG1 Natural Gas H35-LP1 Propane H35 Direct Vent Gas FireplaceTo the New Owner Unit DimensionsHampton Table of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationClearances to Combustibles This includesGAS Stove Locating YourCombustion Ventilation AIRSafety Precautions For the Installer InstallationPrecautions Exterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsHorizontal CapsVenting Arrangements Rotating 45O Elbow for Straight Horizontal TerminationsVertical Terminations Systems for Venting SystemsDura-Vent Snorkel Termination + H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsRequired Parts Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff DURA-VENT Termination KIT Planning Your Dura-Vent InstallationTermination Caps Dura-Vent Basic Horizontal Kit #Diagram 1 Hint Apply silicone to female end DURA-VENT Horizontal InstallationsBelow Grade Snorkel Installation Snorkel TerminationsDURA-VENT Vertical Termination This allows for small adjustments Offset ChartConverting a Factory Built Metal Chimney Appoved for US Installations OnlyGAS Connection Cathedral CeilingsHigh Elevation Clockwise to open Counter-clockwise to close Valve DescriptionBut not overtightened LPG Conversion Kit Contains Qty Description Conversion KIT #791-969 from NG to LPInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Natural Gas Conversion Kit 740-950 Contains Qty Conversion KIT to Lower BTU RatingPropane Conversion Kit 740-952 Contains Qty Burner Orifi ceOptional Brick Panel LOG SET Installation02-46 G 02-44 B 02-56 FPin Cutout Pins on Rear Log SupportLava rock Notch CutoutTile Inset Installation Double Door InstallationTop Tile Inset Side Tile InsetRemove screws Release catch by Pulling up Door Hinge RemovalInstructions Wiring DiagramsWall Thermostat Remote ControlOperating Instructions Automatic Convection FAN Operation Adjusting Flame HeightCopy of the Lighting Plate Instructions Normal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions FAN Maintenance General Vent MaintenanceLOG Replacement Glass ReplacementTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve Replacing the FanMain Assembly Parts ListBrick Panel SET Burner & LOG AssemblyHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.