DV STOVE HORIZONTAL VENT KIT

DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (Part #946-216) includes all the parts needed to install the H35 Direct Vent unit with minimum horizontal and vertical vent dimensions.

For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termination Kit" and "Dura-Vent Venting Components" sections.

 

Qty.

Description

 

1)

1

Rigid Pipe Section (Kit # 946-116: 2 ft. (1.2m) length,

 

 

 

Kit # 946-216: 4 ft. (1.2m) length), 6-1/2" (165mm)

 

 

 

inside diameter

 

2)

1

Flex Liner, compressed aluminium 2 ply liner, 4" (102mm)

 

 

 

inside diameter

 

3)

4

Spring Spacers

 

4)

1

90 deg. Elbow

 

5)

1

Adjustable pipe section 13-1/2" to 24" (343mm x 610mm), 2

pcs.

6)

1

Thimble Cover

 

7)

1

Wall Thimble (2 pcs.)

 

8)

1

Adapter

 

9)1 AstroCap Termination Cap

10)

2

Trim Collars

11)

1

Tube of Mill-Pac, high temperature sealant

12)

12

Screws, #8 x 1/2" Self tapping, Stainless Steel

13)14 Screws, #8 x 1/2" Self tapping, Black

14)

4

Screws #8 x 1-1/2" Drill Point, Black

15)

4

Screws #8 x 1-1/2" Drill Point, Stainless Steel

16)

8

Wood screws #8 x 1"

Required but not included in above Kit: 45o Elbow (Part #: 946-214)

Note:

a)Liner sections should be con- tinuous without any joints or seams.

b)This is an approved system, therefore components in this system must not be substituted for any other manufacturer's products.

DV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION

Review the following sequence of instructions which are typical of most installations. The se- quence may vary depending on wall thickness.

See "Exterior Vent Terminal Locations" to "Venting Arrangements" section for vent location and clearance dimensions, and the "Vent Restrictor Position" section to set the Vent Restrictor to the correct position.

1)Set the unit in its desired location. Check to determine if wall studs will be in the way of the venting system, adjust location until all clearances are met and there are no obstructions.

Note: A1-1/2"(38mm) clearance around the outerpipemustbemaintainedexcept that only a 1" (25mm) clearance is needed at the termination end.

IMPORTANT:

Do not locate termination hood where excessive snow or ice buildupmayoccur.Besuretocheck vent termination area after snow falls,andcleartopreventaccidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

2)Assemble a trial fit to determine the vertical center-line for the vent termination.

a)Cut a 9-1/2" x 9-1/2" (241mm x 241

mm)square hole on both the interior and exterior wall.

b)Install wall thimbles on both interior and exterior wall with 4 wood screws (#8 x 1") per thimble.

c)Attach the 2 piece adjustable pipe sec- tion to the vent terminal and slide into position from the exterior. The larger diameter end of the adjustable pipe goes to the vent terminal.

d)Install the 90o elbow onto the adjust- able pipe to determine the vertical centerline.

Note:ifthecenterlinecannotbemet, the adjustable sections will have to be cut.

e)Cut the 4 ft. section of rigid pipe to length.Attach the 45o elbow to the rigid pipe, and ensure that the pipe length when cut (with the 45o elbow) will seat onto both the starter collar and the 90o elbow. Crimped section of rigid pipe seats into the 90o elbow. Only cut the uncrimped side of pipe.

Dismantle all pipe sections including vent terminal.

18

Hampton® H35 Direct Vent Freestanding Gas Stove

Image 18
Contents H35 Direct Vent Gas Fireplace Models H35-NG1 Natural Gas H35-LP1 PropaneUnit Dimensions HamptonTo the New Owner Table of Contents Safety Label Copy of Safety LabelRequirements MA Code CO DetectorImportant Message Save These Instructions InstallationSpecifications Information for Mobile Manufactured Homes After First SaleClearances to Combustibles General Safety InformationInstallation Checklist This includesCombustion Locating YourGAS Stove Ventilation AIRInstallation PrecautionsSafety Precautions For the Installer Exterior Vent Terminal Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsVertical Terminations Systems for Rotating 45O Elbow for Straight Horizontal TerminationsVenting Arrangements Venting SystemsDura-Vent Snorkel Termination Horizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalStraight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff Termination Caps Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Dura-Vent Basic Horizontal Kit #Below Grade Snorkel Installation DURA-VENT Horizontal InstallationsDiagram 1 Hint Apply silicone to female end Snorkel TerminationsDURA-VENT Vertical Termination Offset Chart This allows for small adjustmentsAppoved for US Installations Only Converting a Factory Built Metal ChimneyCathedral Ceilings High ElevationGAS Connection Valve Description But not overtightenedClockwise to open Counter-clockwise to close Conversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Propane Conversion Kit 740-952 Contains Qty Conversion KIT to Lower BTU RatingNatural Gas Conversion Kit 740-950 Contains Qty Burner Orifi ce02-46 G LOG SET InstallationOptional Brick Panel 02-44 B 02-56 FLava rock Pins on Rear Log SupportPin Cutout Notch CutoutTop Tile Inset Double Door InstallationTile Inset Installation Side Tile InsetDoor Hinge Removal Remove screws Release catch by Pulling upWiring Diagrams InstructionsRemote Control Wall ThermostatOperating Instructions Adjusting Flame Height Copy of the Lighting Plate InstructionsAutomatic Convection FAN Operation Maintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances LOG Replacement General Vent MaintenanceFAN Maintenance Glass ReplacementRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue Replacing the FanParts List Main AssemblyBurner & LOG Assembly Brick Panel SETHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.