Hampton Direct H35-LP1, H35-NG1 Vertical Termination with CO-LINEAR Flex System, Required Parts

Page 17

INSTALLATION

VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements chart below for minimum and maximum fl ue lengths. See chart below for minimum distances from roof. Periodically check that the vent is unrestricted.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical

 

Termination Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter Kit

 

which contains the following:

 

Co-linear Flex Adapter (270-585)

 

Outer Pipe (946-257)

 

Inner Pipe Adapter (946-219)

Alternate Approved Caps

980Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with fl ashing

Venting Arrangements - Vertical Terminations

with Co-linear Flex System for both

Residential & Manufactured Homes

into Masonry Fireplaces

The shaded area in the diagram shows the allowable vertical terminations. Note: Must remove 4 screws from stove collar and rotate 180o to have collar facing straight back. Secure into place with 4 screws.

Straight Vertical Terminations

Vent Restric- tors set at 1-3/4" open(fullyopen), Posiiton "A"

Hampton® H35 Direct Vent Freestanding Gas Stove

17

Image 17
Contents Models H35-NG1 Natural Gas H35-LP1 Propane H35 Direct Vent Gas FireplaceTo the New Owner Unit DimensionsHampton Table of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationClearances to Combustibles This includesGAS Stove Locating YourCombustion Ventilation AIRSafety Precautions For the Installer InstallationPrecautions Exterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsHorizontal CapsVenting Arrangements Rotating 45O Elbow for Straight Horizontal TerminationsVertical Terminations Systems for Venting SystemsDura-Vent Snorkel Termination + H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsRequired Parts Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff DURA-VENT Termination KIT Planning Your Dura-Vent InstallationTermination Caps Dura-Vent Basic Horizontal Kit #Diagram 1 Hint Apply silicone to female end DURA-VENT Horizontal InstallationsBelow Grade Snorkel Installation Snorkel TerminationsDURA-VENT Vertical Termination This allows for small adjustments Offset ChartConverting a Factory Built Metal Chimney Appoved for US Installations OnlyGAS Connection Cathedral CeilingsHigh Elevation Clockwise to open Counter-clockwise to close Valve DescriptionBut not overtightened LPG Conversion Kit Contains Qty Description Conversion KIT #791-969 from NG to LPInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Natural Gas Conversion Kit 740-950 Contains Qty Conversion KIT to Lower BTU RatingPropane Conversion Kit 740-952 Contains Qty Burner Orifi ceOptional Brick Panel LOG SET Installation02-46 G 02-44 B 02-56 FPin Cutout Pins on Rear Log SupportLava rock Notch CutoutTile Inset Installation Double Door InstallationTop Tile Inset Side Tile InsetRemove screws Release catch by Pulling up Door Hinge RemovalInstructions Wiring DiagramsWall Thermostat Remote ControlOperating Instructions Automatic Convection FAN Operation Adjusting Flame HeightCopy of the Lighting Plate Instructions Normal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions FAN Maintenance General Vent MaintenanceLOG Replacement Glass ReplacementTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve Replacing the FanMain Assembly Parts ListBrick Panel SET Burner & LOG AssemblyHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.