Hampton Direct H35-LP1, H35-NG1 General Vent Maintenance, FAN Maintenance, LOG Replacement

Page 41

MAINTENANCE

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These com- ponents should be replaced immediately.

2)Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.

3)Checkforevidencesofexcessivecondensa- tion, such as water droplets forming in the innerliner,andsubsequentlydrippingoutthe joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, toomanyelbows,andexteriorportionsofthe system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

1) Lift off the Cast Top.

2) Open the 2 latches of the Glass Front.

FAN MAINTENANCE

If your fan requires maintenance or replace- ment, access to the fan is through the rear access panel on the back of the unit. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

WARNING:

Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut orremovethegroundingprongfrom this plug.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

GLASS

REPLACEMENT

Your stove is supplied with high temperature, 5

mmNeoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement door from an au- thorized Hampton® dealer only, and follow our step-by-step instructions for replacement.

Latches

3) Lift the Glass Front Assembly up.

4)Remove the glass and replace with the new glass.

5)Replace the door and Cast Top.

Replacement Part # 940-324 Glass

WARNING: Do not operate appli- ance with glass panel removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service per- son.

Note: Wearing gloves will protect your hands while handling glass.

IMPORTANT

Disconnect power supply

before servicing

To remove fan:

1)Unplug or disconnect power source to stove.

2)Remove the 6 screws holding the access panel in place.

3)Unclip the black and white wires from the fan motor.

4)Lift fan off of the 2 pins, tip back and pull through rear panel. Do not tear or damage the flex pipe when removing the fan. Discon- nect the green ground wire from the right side of the fan as soon as you can reach it.

Hampton® H35 Direct Vent Freestanding Gas Stove

41

Image 41
Contents Models H35-NG1 Natural Gas H35-LP1 Propane H35 Direct Vent Gas FireplaceTo the New Owner Unit DimensionsHampton Table of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationClearances to Combustibles This includesGAS Stove Locating YourCombustion Ventilation AIRSafety Precautions For the Installer InstallationPrecautions Exterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsHorizontal CapsVenting Arrangements Rotating 45O Elbow for Straight Horizontal TerminationsVertical Terminations Systems for Venting SystemsDura-Vent Snorkel Termination + H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsRequired Parts Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff DURA-VENT Termination KIT Planning Your Dura-Vent InstallationTermination Caps Dura-Vent Basic Horizontal Kit #Diagram 1 Hint Apply silicone to female end DURA-VENT Horizontal InstallationsBelow Grade Snorkel Installation Snorkel TerminationsDURA-VENT Vertical Termination This allows for small adjustments Offset ChartConverting a Factory Built Metal Chimney Appoved for US Installations OnlyGAS Connection Cathedral CeilingsHigh Elevation Clockwise to open Counter-clockwise to close Valve DescriptionBut not overtightened LPG Conversion Kit Contains Qty Description Conversion KIT #791-969 from NG to LPInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Natural Gas Conversion Kit 740-950 Contains Qty Conversion KIT to Lower BTU RatingPropane Conversion Kit 740-952 Contains Qty Burner Orifi ceOptional Brick Panel LOG SET Installation02-46 G 02-44 B 02-56 FPin Cutout Pins on Rear Log SupportLava rock Notch CutoutTile Inset Installation Double Door InstallationTop Tile Inset Side Tile InsetRemove screws Release catch by Pulling up Door Hinge RemovalInstructions Wiring DiagramsWall Thermostat Remote ControlOperating Instructions Automatic Convection FAN Operation Adjusting Flame HeightCopy of the Lighting Plate Instructions Normal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions FAN Maintenance General Vent MaintenanceLOG Replacement Glass ReplacementTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve Replacing the FanMain Assembly Parts ListBrick Panel SET Burner & LOG AssemblyHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.