Hampton Direct H35-LP1, H35-NG1 installation manual Table of Contents

Page 3

TABLE OF CONTENTS

Unit Dimensions

2

SAFETY LABEL

 

Copy of Safety Label

4

REQUIREMENTS

 

MA Code - CO Detector

 

(for state of Massachusetts only)

5

INSTALLATION

 

Specifi cations

6

Information for Mobile / Manufactured

 

Homes After First Sale

6

General Safety Information

7

Installation Checklist

7

Clearances to Combustibles

7

Locating Your Gas Stove

8

Manufactured Mobile Home Additional Requirements ..

8

Combustion and Ventilation Air

8

Optional Fan Installation

8

Venting Introduction

9

Installation Precautions

9

Safety Precautions for The Installer

9

Vent Restrictor Position

9

Exterior Vent Terminal Locations

10

Rigid Pipe Venting Components List

11

Rigid Pipe Venting Systems

12

Rotating 45o Elbow for Straight

 

Horizontal Terminations

13

Venting Arrangements

13

Vertical Termination With Co-linear Flex System

17

DV Stove Horizontal Vent Kit

18

Dura-Vent Termination Kit

20

Dura-Vent Horizontal Installations

21

Dura-Vent Vertical Termination

22

Converting Class-A Metal Chimney or

 

Masonry Chimney

24

Cathedral Ceilings

25

High Elevation

25

Gas Connection

25

Aeration Adjustment

26

Gas Pipe Pressure Testing

26

Conversion Kit #791-969 from NG to LP

27

Conversion Kit to Lower BTU Rating

31

Brick Panel

32

Log Set Installation

32

Double Door Installation

34

Decorative Door Grill Installation

34

Tile Inset Installation

34

Door Hinge Removal

35

Wiring Diagrams

36

Wall Thermostat

37

Remote Control

37

OPERATING INSTRUCTIONS

 

Operating Instructions

38

Lighting Procedure

38

Shutdown Procedure

38

First Fire

38

Final Check

38

Copy of the Lighting Plate Instructions

39

Adjusting Flame Height

39

Automatic Convection Fan Operation

39

MAINTENANCE

 

Normal Operating Sounds of Gas Appliances

40

Maintenance Instructions

40

General Vent Maintenance

41

Log Replacement

41

Glass Replacement

41

Fan Maintenance

41

Removing Valve

42

Installing Valve Assembly

42

PARTS LIST

 

Main Assembly

43

Burner & Log Assembly

44

WARRANTY

 

Warranty

47

Hampton® H35 Direct Vent Freestanding Gas Stove

3

Image 3
Contents Models H35-NG1 Natural Gas H35-LP1 Propane H35 Direct Vent Gas FireplaceUnit Dimensions HamptonTo the New Owner Table of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsInformation for Mobile Manufactured Homes After First Sale InstallationSpecifications Important Message Save These InstructionsThis includes General Safety InformationInstallation Checklist Clearances to CombustiblesVentilation AIR Locating YourGAS Stove CombustionInstallation PrecautionsSafety Precautions For the Installer Exterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListCaps Rigid Pipe Venting SystemsAlternate HorizontalVenting Systems Rotating 45O Elbow for Straight Horizontal TerminationsVenting Arrangements Vertical Terminations Systems forDura-Vent Snorkel Termination + H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsAlternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemRequired Parts Straight Vertical TerminationsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff Dura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Termination CapsSnorkel Terminations DURA-VENT Horizontal InstallationsDiagram 1 Hint Apply silicone to female end Below Grade Snorkel InstallationDURA-VENT Vertical Termination This allows for small adjustments Offset ChartConverting a Factory Built Metal Chimney Appoved for US Installations OnlyCathedral Ceilings High ElevationGAS Connection Valve Description But not overtightenedClockwise to open Counter-clockwise to close LPG Conversion Kit Contains Qty Description Conversion KIT #791-969 from NG to LPInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Burner Orifi ce Conversion KIT to Lower BTU RatingNatural Gas Conversion Kit 740-950 Contains Qty Propane Conversion Kit 740-952 Contains Qty02-44 B 02-56 F LOG SET InstallationOptional Brick Panel 02-46 GNotch Cutout Pins on Rear Log SupportPin Cutout Lava rockSide Tile Inset Double Door InstallationTile Inset Installation Top Tile InsetRemove screws Release catch by Pulling up Door Hinge RemovalInstructions Wiring DiagramsWall Thermostat Remote ControlOperating Instructions Adjusting Flame Height Copy of the Lighting Plate InstructionsAutomatic Convection FAN Operation Maintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances Glass Replacement General Vent MaintenanceFAN Maintenance LOG ReplacementReplacing the Fan Installing Valve AssemblyTo remove valve from valve assembly, continue Removing ValveMain Assembly Parts ListBrick Panel SET Burner & LOG AssemblyHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.