Hampton Direct H35-NG1 Installation, Important Message Save These Instructions, Specifications

Page 6

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The DirectVentFreestandingGasStovemustbe installed in accordance with these instructions. Carefully read all the instructions in this manual

rst. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

Note:Theseinstructionstakeprecedenceover Simpson Dura-Vent instructions.

SPECIFICATIONS

Fuels: H35-NG1 is approved for use with natural gas.

H35-LP1 is approved for use with liquefied petroleum gases (propane).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 125/75.

Log Sets: Ceramic fi bre, 7 per set.

Vent System: Coaxial (6-5/8" outer / 4" inner liner) rigid fl ue and termination cap.

The effi ciency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independent of any installed system.

INFORMATION FOR

MOBILE /

MANUFACTURED

HOMES

AFTER FIRST SALE

This Hampton® product has been tested and listed by ITS Testing Services as a Direct Vent Wall Furnace to the following standards:

CGA-2.17-M91, and ANSI Z21.88b-2003/CSA 2.33b-2003.

This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured

Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA501A,andwithCAN/CSAZ240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code,ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This Hampton® Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.

This Hampton® Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 18 gauge copper wire from the steel chassis ground must be attached.

Thisappliancemayonlybeinstalledin an aftermarket permanently located, manufactured (USA only )or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALI- FIED SERVICE PERSON. THISAP- PLIANCESHOULDBEINSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PER- SON. MORE FREQUENT CLEAN- ING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPET- ING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNERS AND CIRCULATING

AIR PASSAGEWAYS OF THE AP- PLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFICAND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLE MATERIALSHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

1)Provide adequate clearances for servicing, properoperationandaroundtheairopenings into the combustion chamber.

2)The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or it can be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, tile, wood fl ooring or other com- bustible material, because the appliance's base extends the full width and depth of the appliance. The Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fi t nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a cor- ner.

3)The Direct Vent Freestanding Gas Stove is approved for alcove installations, which meet the clearances listed in the "Clear- ance to Combustibles" section. This unit is approved for manufactured home installa- tions, see the "Manufactured Mobile Home Additional Requirements" section and the "Venting Arrangement" section for the re- quired vent arrangements. If installed into a

6

Hampton® H35 Direct Vent Freestanding Gas Stove

Image 6
Contents H35 Direct Vent Gas Fireplace Models H35-NG1 Natural Gas H35-LP1 PropaneUnit Dimensions HamptonTo the New Owner Table of Contents Safety Label Copy of Safety LabelRequirements MA Code CO DetectorImportant Message Save These Instructions InstallationSpecifications Information for Mobile Manufactured Homes After First SaleClearances to Combustibles General Safety InformationInstallation Checklist This includesCombustion Locating YourGAS Stove Ventilation AIRInstallation PrecautionsSafety Precautions For the Installer Exterior Vent Terminal Locations Rigid Pipe Venting Components List SV4LB6Horizontal Rigid Pipe Venting SystemsAlternate CapsVertical Terminations Systems for Rotating 45O Elbow for Straight Horizontal TerminationsVenting Arrangements Venting SystemsDura-Vent Snorkel Termination Horizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalStraight Vertical Terminations Vertical Termination with CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff Termination Caps Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Dura-Vent Basic Horizontal Kit #Below Grade Snorkel Installation DURA-VENT Horizontal InstallationsDiagram 1 Hint Apply silicone to female end Snorkel TerminationsDURA-VENT Vertical Termination Offset Chart This allows for small adjustmentsAppoved for US Installations Only Converting a Factory Built Metal ChimneyCathedral Ceilings High ElevationGAS Connection Valve Description But not overtightenedClockwise to open Counter-clockwise to close Conversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Propane Conversion Kit 740-952 Contains Qty Conversion KIT to Lower BTU RatingNatural Gas Conversion Kit 740-950 Contains Qty Burner Orifi ce02-46 G LOG SET InstallationOptional Brick Panel 02-44 B 02-56 FLava rock Pins on Rear Log SupportPin Cutout Notch CutoutTop Tile Inset Double Door InstallationTile Inset Installation Side Tile InsetDoor Hinge Removal Remove screws Release catch by Pulling upWiring Diagrams InstructionsRemote Control Wall ThermostatOperating Instructions Adjusting Flame Height Copy of the Lighting Plate InstructionsAutomatic Convection FAN Operation Maintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances LOG Replacement General Vent MaintenanceFAN Maintenance Glass ReplacementRemoving Valve Installing Valve AssemblyTo remove valve from valve assembly, continue Replacing the FanParts List Main AssemblyBurner & LOG Assembly Brick Panel SETHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.