Hampton Direct H35-LP1, H35-NG1 installation manual A m O u l d be facing Down Nylsidingstandoff

Page 19

INSTALLATION

3)Attach the 4" dia. fl ex liner to the vent terminal ensuring that the fl ex overlaps the collar of the vent terminal by a minimum of 1-3/8"(35mm). Use Mill-Pac to seal and secure with 3 of the #8 x 1/2" screws (stain- less steel).

4)Attach the adjustable pipe section to the vent terminal using Mill-Pac and/or high temperature silicone and attach with 3 of the #8 x 1/2" screws (stainless steel).

Hint: Apply the sealant (Mill-Pac and/or high temperature silicone) to the outer pipe before connecting the inner pipe.

Note: The pipe

s e a m

s h o u l d be facing

down.

Note: To make the installation more aes- thetically pleasing, we recommend framing out a square that the cap can be mounted on.

Note: If installing termi- nation on a siding covered wall, a vi-

nylsidingstandoff

or furring strips must be used to ensure that the termination is not recessed into the

siding. For vinyl siding standoff installation refer to the Dura-Vent Termination instructions.

5)Slide the partially connected pipe and vent terminal assembly through the wall thim- bles (from the exterior into the interior) and secure the cap to the exterior wall with 4 of the supplied screws (#8 x 1-1/2" drill point, stainless steel). Note: pilot holes will need to be drilled through the wall thimble on all 4 corners.

Note: The four screws provided for the vent cap should be replaced with ap- propriate fasteners for stucco, brick, concrete, or other types of sidings.

6)A bead of non-hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from enter- ing and to make a tight seal between the cap and the standoff.

7)Stretch the 4" dia. fl ex liner out fully and get a trial fi t of the liner onto the 4" dia. starter collar.

8)Cut the 4" dia. fl ex liner to the desired size.

Hint: leave an extra 12" to 16" of length, this will make the fi nal assembly easier to work with.

9)Secure the 4" dia. fl ex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel).

10)Slide the decorativeThimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2" drill point, black) to the wall.

11)Slide the 90o elbow (crimp end up), the 45o elbow and the 4 ft. pipe section (crimp end up) over the 4" dia. fl ex liner.

12)Install the spring spacers onto the pipe sections.

13)Secure the 4" dia. fl ex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel).

14)Attach the 45o elbow onto the starter collar by sealing with Mill-Pac and/or high tem- perature silicone and securing with 3 of the #8 x 1/2" (black) screws.

15)Attach the pipe section to the 45o elbow by sealing with Mill-Pac and/or high tempera- ture silicone and securing with 3 of the #8 x 1/2" screws (black). Pipe seams should be facing the wall.

16)Attach the 90o elbow onto the pipe section by sealing with Mill-Pac and/or high tem- perature silicone and securing with 3 of the #8 x 1/2" screws (black).

17)Slide the adjustable pipe section onto the 90o elbow. Slide the trim collar over the adjustable pipe sections to cover the joint of the telescopic section.) The fl ex may have to be compressed back in order for the adjustable pipe to properly mate to the elbow. Seal with Mill-Pac and/or high temperature silicone and secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down.

18)Install the trim collar over the starter collar and secure with a #8 x 1/2" screw (black).

If the pipe needs to be touched up, use only Stove Brite High Temperature Metallic Black Stove Paint.

NOTE: All inner joints must be sealed with Mill-Pac. All outer joints may be sealed with high temperature silicone.

Hampton® H35 Direct Vent Freestanding Gas Stove

19

Image 19
Contents Models H35-NG1 Natural Gas H35-LP1 Propane H35 Direct Vent Gas FireplaceHampton Unit DimensionsTo the New Owner Table of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsInformation for Mobile Manufactured Homes After First Sale InstallationSpecifications Important Message Save These InstructionsThis includes General Safety InformationInstallation Checklist Clearances to CombustiblesVentilation AIR Locating YourGAS Stove CombustionPrecautions InstallationSafety Precautions For the Installer Exterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListCaps Rigid Pipe Venting SystemsAlternate HorizontalVenting Systems Rotating 45O Elbow for Straight Horizontal TerminationsVenting Arrangements Vertical Terminations Systems forDura-Vent Snorkel Termination + H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsAlternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemRequired Parts Straight Vertical TerminationsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff Dura-Vent Basic Horizontal Kit # Planning Your Dura-Vent InstallationDURA-VENT Termination KIT Termination CapsSnorkel Terminations DURA-VENT Horizontal InstallationsDiagram 1 Hint Apply silicone to female end Below Grade Snorkel InstallationDURA-VENT Vertical Termination This allows for small adjustments Offset ChartConverting a Factory Built Metal Chimney Appoved for US Installations OnlyHigh Elevation Cathedral CeilingsGAS Connection But not overtightened Valve DescriptionClockwise to open Counter-clockwise to close LPG Conversion Kit Contains Qty Description Conversion KIT #791-969 from NG to LPInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Burner Orifi ce Conversion KIT to Lower BTU RatingNatural Gas Conversion Kit 740-950 Contains Qty Propane Conversion Kit 740-952 Contains Qty02-44 B 02-56 F LOG SET InstallationOptional Brick Panel 02-46 GNotch Cutout Pins on Rear Log SupportPin Cutout Lava rockSide Tile Inset Double Door InstallationTile Inset Installation Top Tile InsetRemove screws Release catch by Pulling up Door Hinge RemovalInstructions Wiring DiagramsWall Thermostat Remote ControlOperating Instructions Copy of the Lighting Plate Instructions Adjusting Flame HeightAutomatic Convection FAN Operation Maintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances Glass Replacement General Vent MaintenanceFAN Maintenance LOG ReplacementReplacing the Fan Installing Valve AssemblyTo remove valve from valve assembly, continue Removing ValveMain Assembly Parts ListBrick Panel SET Burner & LOG AssemblyHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.