PARTS LIST

BURNER & LOG ASSEMBLY

Part #

Description

740-574/P Valve Assembly S.I.T. - Natural Gas

740-576/P Valve Assembly S.I.T. - Propane

60)910-478 Valve S.I.T. - NG/LP

904-689 #33 Orifi ce - N.G.

904-645 #51 Orifi ce - LP

63)910-190 Piezo Ignitor & Nut

64)908-672 Control Panel Decal

65) 490-061

Switch Plate

910-897

High Temperature Wire

 

Harness (Fan End)

936-170

Orifi ce Gasket

66)910-038 Pilot Assy-SIT-3ame-NG

910-039

Pilot Assy-SIT-3ame-LP

67) 730-041

Pilot Holder

68)W840470 Pilot Assembly Gasket

69)

*

Valve Shield

70)

*

Valve Bracket

71)

*

Valve Gasket

72)

*

Front Support

73)730-528 Rear Log Bracket Assy

75)

402-935

Log Set

 

740-572

Ember Package

78)

730-550

Burner Assy

 

740-546

Base Assembly

79)

*

Base Plate

80)

*

Brick Panel - Right Side

81)

*

Brick Panel - Left Side

82)

*

Brick Panel - Back

83)

400-090

Brick Clip

84)

948-042

Hinge of Valve

 

 

Access Door

85)260-056 Valve Access Door

86)260-565 Air Shutter Gear Assembly - Female

87)904-700 T-Handle Hex Key 3/16"

88)630-008 Burner Tray Firebox Gasket

89)260-560 Air Shutter Gear Assembly

-Male

90) *

Burner Box

791-969 Conversion Kit from Natural Gas to Propane

*Note: Not available as a replacement part.

83

82

83

81

BRICK PANEL SET 80

44

Hampton® H35 Direct Vent Freestanding Gas Stove

Image 44
Contents H35 Direct Vent Gas Fireplace Models H35-NG1 Natural Gas H35-LP1 PropaneTo the New Owner Unit DimensionsHampton Table of Contents Safety Label Copy of Safety LabelRequirements MA Code CO DetectorInstallation SpecificationsImportant Message Save These Instructions Information for Mobile Manufactured Homes After First SaleGeneral Safety Information Installation ChecklistClearances to Combustibles This includesLocating Your GAS StoveCombustion Ventilation AIRSafety Precautions For the Installer InstallationPrecautions Exterior Vent Terminal Locations Rigid Pipe Venting Components List SV4LB6Rigid Pipe Venting Systems AlternateHorizontal CapsRotating 45O Elbow for Straight Horizontal Terminations Venting ArrangementsVertical Terminations Systems for Venting SystemsDura-Vent Snorkel Termination Horizontal Venting with Two 2 90o Elbows + H1 With these options, maxVertical Venting with Two 2 90o Elbows + V1 With these options, max. totalVertical Termination with CO-LINEAR Flex System Required PartsStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff Planning Your Dura-Vent Installation DURA-VENT Termination KITTermination Caps Dura-Vent Basic Horizontal Kit #DURA-VENT Horizontal Installations Diagram 1 Hint Apply silicone to female endBelow Grade Snorkel Installation Snorkel TerminationsDURA-VENT Vertical Termination Offset Chart This allows for small adjustmentsAppoved for US Installations Only Converting a Factory Built Metal ChimneyGAS Connection Cathedral CeilingsHigh Elevation Clockwise to open Counter-clockwise to close Valve DescriptionBut not overtightened Conversion KIT #791-969 from NG to LP LPG Conversion Kit Contains Qty DescriptionInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Conversion KIT to Lower BTU Rating Natural Gas Conversion Kit 740-950 Contains QtyPropane Conversion Kit 740-952 Contains Qty Burner Orifi ceLOG SET Installation Optional Brick Panel02-46 G 02-44 B 02-56 FPins on Rear Log Support Pin CutoutLava rock Notch CutoutDouble Door Installation Tile Inset InstallationTop Tile Inset Side Tile InsetDoor Hinge Removal Remove screws Release catch by Pulling upWiring Diagrams InstructionsRemote Control Wall ThermostatOperating Instructions Automatic Convection FAN Operation Adjusting Flame HeightCopy of the Lighting Plate Instructions Normal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions General Vent Maintenance FAN MaintenanceLOG Replacement Glass ReplacementInstalling Valve Assembly To remove valve from valve assembly, continueRemoving Valve Replacing the FanParts List Main AssemblyBurner & LOG Assembly Brick Panel SETHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.