INSTALLATION

VENTING

INSTALLATION

VENT RESTRICTOR

INTRODUCTION

PRECAUTIONS

POSITION

The Horizontal Termination Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the Direct Vent Freestanding Gas Stoves, H35-NG1, and H35-LP1, have been tested and listed as direct vent heater systems by Warnock Hersey.

These units use the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combus- tion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be connected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fi re or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.

Thelocationoftheterminationcapmustconform totherequirementsinthe"ExteriorVentTerminal Locations" section.

These venting systems are engineered products that have been designed and tested for use with the H35-NG1, and H35-LP1. The warranty will be voided and serious fi re, health or other safety hazards may result from any of the fol- lowing actions:

1)Installation of any damaged Direct Vent component

2)Unauthorized modification of the Direct Vent System

3)Installation of any component part not manu- factured or approved by Simpson Dura-Vent or FPI Fireplace Products International Ltd.

4)Installation other than as instructed by Simp- son Dura-Vent and FPI Fireplace Products International Ltd.

Warning: Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation.

Be sure to check the vent termination clearance requirements from decks, windows, soffi ts, gas regulators, air supply inlets and public walkways as specifi ed in the "Exterior Vent Terminal Locations" section and in your local building codes.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appli- ance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

Vent restriction is required for certain venting installations, see the diagrams in "Venting Arrangment" section to determine if they are required for your installation.

To set the Vent restriction as indicated in the diagrams in the "VentingArrangement" section, simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws.

Horizontal Termination:

Vent Restrictor setting at 36,000 Btu/h

Vertical Termination:

Vent Restrictor setting at 36,000 Btu/h

SAFETY PRECAUTIONS

FOR THE INSTALLER

1)Wear gloves and safety glasses for protec- tion.

2)Exercise extreme caution when using lad- ders or on roof tops.

3)Be aware of electrical wiring locations in walls and ceilings.

Hampton® H35 Direct Vent Freestanding Gas Stove

9

Image 9
Contents Models H35-NG1 Natural Gas H35-LP1 Propane H35 Direct Vent Gas FireplaceUnit Dimensions HamptonTo the New Owner Table of Contents Copy of Safety Label Safety LabelMA Code CO Detector RequirementsSpecifications InstallationImportant Message Save These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationClearances to Combustibles This includesGAS Stove Locating YourCombustion Ventilation AIRInstallation PrecautionsSafety Precautions For the Installer Exterior Vent Terminal Locations SV4LB6 Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsHorizontal CapsVenting Arrangements Rotating 45O Elbow for Straight Horizontal TerminationsVertical Terminations Systems for Venting SystemsDura-Vent Snorkel Termination + H1 With these options, max Horizontal Venting with Two 2 90o Elbows+ V1 With these options, max. total Vertical Venting with Two 2 90o ElbowsRequired Parts Vertical Termination with CO-LINEAR Flex SystemStraight Vertical Terminations Alternate Approved CapsDV Stove Horizontal Vent KIT A m O u l d be facing Down Nylsidingstandoff DURA-VENT Termination KIT Planning Your Dura-Vent InstallationTermination Caps Dura-Vent Basic Horizontal Kit #Diagram 1 Hint Apply silicone to female end DURA-VENT Horizontal InstallationsBelow Grade Snorkel Installation Snorkel TerminationsDURA-VENT Vertical Termination This allows for small adjustments Offset ChartConverting a Factory Built Metal Chimney Appoved for US Installations OnlyCathedral Ceilings High ElevationGAS Connection Valve Description But not overtightenedClockwise to open Counter-clockwise to close LPG Conversion Kit Contains Qty Description Conversion KIT #791-969 from NG to LPInstallation of the DC Sparker for the H35-1 Units Only Installation of the DC Sparker For the P90 Units Only Ground Wire from Kit Natural Gas Conversion Kit 740-950 Contains Qty Conversion KIT to Lower BTU RatingPropane Conversion Kit 740-952 Contains Qty Burner Orifi ceOptional Brick Panel LOG SET Installation02-46 G 02-44 B 02-56 FPin Cutout Pins on Rear Log SupportLava rock Notch CutoutTile Inset Installation Double Door InstallationTop Tile Inset Side Tile InsetRemove screws Release catch by Pulling up Door Hinge RemovalInstructions Wiring DiagramsWall Thermostat Remote ControlOperating Instructions Adjusting Flame Height Copy of the Lighting Plate InstructionsAutomatic Convection FAN Operation Maintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances FAN Maintenance General Vent MaintenanceLOG Replacement Glass ReplacementTo remove valve from valve assembly, continue Installing Valve AssemblyRemoving Valve Replacing the FanMain Assembly Parts ListBrick Panel SET Burner & LOG AssemblyHampton H35 Direct Vent Freestanding Gas Stove Hampton H35 Direct Vent Freestanding Gas Stove Conditions WarrantyInstaller Please complete the following information

H35-NG1, H35-LP1 specifications

Hampton Direct has made significant strides in the home heating sector with its innovative products, particularly the H35-NG1 and H35-LP1 models. Both are designed to provide efficient heating solutions suitable for various residential settings.

The H35-NG1 is a natural gas unit, while the H35-LP1 runs on liquid propane, allowing homeowners to choose based on their available energy resources. One of the standout features of both models is their compact design, making them ideal for small spaces or rooms where traditional heaters would be impractical.

Another key characteristic is the user-friendly digital thermostat that comes with each unit. This feature allows homeowners to easily set and adjust their desired temperature, ensuring optimal comfort throughout the day while also promoting energy efficiency. The systems are equipped with smart technology that monitors usage patterns, helping homeowners make informed decisions about their heating needs.

Safety is also at the forefront of Hampton Direct's design. Both models include advanced safety features such as an automatic shut-off mechanism to prevent overheating and a fault detection system that alerts users to any issues. This commitment to safety provides peace of mind for homeowners as they enjoy the warmth provided by these heaters.

Additionally, both the H35-NG1 and H35-LP1 are engineered to minimize noise, ensuring a quiet operation that won't disrupt daily activities. This is particularly beneficial for bedrooms or living areas where a peaceful environment is desired.

The energy efficiency rating of these units is impressive, aligning with modern environmental standards. Homeowners can expect lower utility bills and a reduced carbon footprint as both heaters efficiently convert fuel into heat.

With robust construction materials designed to withstand high temperatures, both models promise durability and longevity with minimal maintenance required. This reliability ensures that consumers will not face frequent replacements, making the H35-NG1 and H35-LP1 sound investments for any home.

In summary, Hampton Direct's H35-NG1 and H35-LP1 models deliver effective and safe heating solutions with an emphasis on energy efficiency, user-friendliness, and quiet operation. Homeowners looking for a dependable heating system will find that these models embody quality and innovation, setting new standards in the home heating industry.