INSTALLATION

c)Before connecting the vent pipe to the vent termination, slide the black decorative wall thimble cover over the vent pipe, then slide the Wall Penetration Heat Shield (Part # 946-202) over the vent pipe. Dia. 3.

d)Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the riser vent terminal assem- bly. It is important that the vent pipe extends into the Riser Vent Backing Plate a suffi- cient distance so as to result in a minimum pipe overlap of 1-1/4 inches. Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the Riser Vent Back- ing Plate into the outer wall of the vent pipe. Use two aluminum screws provided to connect the strips to the pipe section. Bend any remaining portion of the sheet metal strip back towards the vent cap and cut off any excess, it will be concealed by the decorative wall thimble cover. See diagram 5.

VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. The flue length must be a minimum length of 8 ' (2.44m) and a maximum of 35' (10.7m). See chart for minimum distances from roof. Periodically check that the vent is unrestricted.

Masonry chimneys may take various contours which the flexible liner will accommo- date. However, keep the flexible liner as straight as possible , avoid unnec- essary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Diagram 5

8)Slide the decorative wall thimble up to the wall surface being careful not to scratch the paint. See diagram 5.

9)Back outside: Apply sealant to the 4" inner flue and slide the Riser Vent Front into the Backing Plate and fasten with 8 screws.

IMPORTANT:

When connecting the pipe to the Riser Vent, apply Mill-Pac to the inner pipe on the Riser Vent Terminal, around the bead. Ensure

that the vent pipe is pushed past the bead for a secure fit.

10)Seal around the outer edge of the Riser Vent Backing Plate.

Required Parts:

Part #

Description

945G

45o Elbow

946-529

Co-linear DV Vertical

 

Termination Cap

948-305

3" Flex - 35 ft.

270-944

U27 Dura-Vent Adapter

946-563

Co-Axial to Co-Linear

 

Adapter Kit which

 

contains the following:

Co-linear Flex Adapter (270-585)

Outer Pipe (946-257)

Inner Pipe Adapter (946-219)

Alternate Approved Caps

980

Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with flashing

Waterford TARA T25 Direct Vent Freestanding Gas Stove

13

Image 13
Contents Tara Direct Vent Freestanding Gas Stove To the New Owner WaterfordTable of Contents Copy of Safety Label for Tara T25 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationManufactured Mobile Home Additional Requirements Clearances to CombustiblesLocating Your GAS Stove Optional FAN InstallationTara Clearances Installation Combustion and Ventilation AIR Exterior Vent Terminal For your particular installation Planning Your venting InstallationMinimum components for a Horizontal Installation Quired. Other parts may be requiredBelow Grade Snorkel Installation Horizontal InstallationsSnorkel Terminations Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps Qty. Description DV Stove Horizontal Vent KITDURA-VENT Termination KIT Planning Your Dura-Vent InstallationAlternate Horizontal Termination Caps Rigid Pipe Venting Components4DT-AJB Rigid Pipe Venting Components ListRigid Pipe Venting Vertical Terminations Rigid Pipe Venting Horizontal TerminationsFor both Residential & Manufactured Homes/Mobile Homes Vent Restrictor DURA-VENT Horizontal InstallationsTermination Cathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse Round Support RDS Square Support SQSConverting a Factory Built Metal Chimney Converting a Masonry ChimneySystem Data Tara T25 High ElevationGAS Connection GAS Pipe Pressure TestingConversion KIT From Natural GAS To Propane Valve DescriptionReplace yellow Natural Gas label with red Propane label Removing Cast Iron Front Panel Aeration AdjustmentOptional Front Grill Securing Cast Iron Front PanelOptional Side Shelf LOG InstallationOptional Wall Thermostat Wiring Diagram Tara Optional Remote ControlThermostat Wire Table Final CheckOperating Instructions Sounds Maintenance Instructions MaintenanceGeneral Vent Maintenance LOG ReplacementFAN Maintenance Glass ReplacementValve Maintenance Installing Valve AssemblyReplacement / Spare Parts List Parts ListPage Conditions WarrantyRegister your Waterford online at