INSTALLATION
Use the minimum clearances shown in the diagrams below:
TARA Clearances |
| |||
Side Wall to Unit* | A | 6" | / | 150 mm |
Back Wall to Unit | B | 3" | / | 75 mm |
Unit Corner to Wall | C | 2" | / | 50 mm |
Unit to Alcove Ceiling |
| 13" / | 330 mm | |
Max. Alcove Depth |
| 24" / | 610 mm |
*If installing the side shelves, which are 6" wide, additional space is required.
Minimum ceiling height is 47"/1294mm from floor.
A)Cross Corner
B)Room Divider
C)Island
D)Flat on Wall
E)Flat on Wall Corner
F)Flush with Wall/Alcove
3)Remove the Top Control Panel Assembly by removing the three screws.
Top Control Panel Assembly
4) | Remove the nylon hole plug from the control |
| panel. |
5) | Install the fan speed controller onto the |
| control panel and secure with nut and |
| washer. Connect the red and black wires |
OPTIONAL FAN
INSTALLATION
for units starting with serial #
11106 to 13347 / 217000001 to present.
Fan Kit Contains:
Qty. Description
1Fan Assembly c/w green wire attached
1Thermodisc
1power cord
2
1)Remove the thermodisc from the bracket on the fan assembly, do not disconnect the wires.
from the wire harness to speed controller. |
NOTE: Speed control wires must be in the |
down position when control panel is in |
place. |
Fan Speed
Controller
LOCATING YOUR
GAS STOVE
When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.
For Vent Termination requirements, see page 10.
Thermodisc
2)Remove the rear access panel on the back of the stove by removing the 6 screws. Take care not to cut wires when lowering the panel.
Rear Access Panel
secured with 6 screws
(3 on each side)
6)Push black knob onto speed control.
7)
8)Mount the blower assembly in position un- der the base of the stove and secure with the 2 supplied bolts
Waterford TARA T25 Direct Vent Freestanding Gas Stove | 7 |