Waterford Appliances T25-LP, T25-NG Maintenance Instructions, General Vent Maintenance

Page 31

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1)

Always turn off the valve before cleaning.

 

For relighting, refer to lighting instructions.

 

Keep the burner and control compartment

 

clean by brushing and vacuuming at least

 

once a year. When cleaning the logs, use

 

a soft clean paint brush as the logs are

 

fragile and easily damaged.

2)

Clean glass (never when unit is hot), appli-

 

ance, and door with a damp cloth. Never

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SUR- FACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear of the burner or thermopile.

use an abrasive cleaner.

The porcelain enamel finished stoves may

be cleaned with ordinary household glass

cleaner and a soft cloth or paper towel.

Never clean when unit is hot and never use

an abrasive cleaner.

3) The heater is finished in a porcelain finish

or with a heat resistant paint and should

only be refinished with heat resistant paint

(not with wall paint). Waterford uses Stove-

Bright Paint - Metallic Black #6309.

Never use an abrasive cleaner on the

porcelain finish as it may scratch the sur-

face.

4) Make a periodic check of burner for proper

position and condition. Visually check the

flame of the burner periodically, making

sure the flames are steady; not lifting or

floating. If there is a problem, call a qualified

service person.

5) Caution: Label all wires prior to disconnec-

tion when servicing controls. Wiring errors

can cause improper and dangerous oper-

ation.

6) The appliance and venting system must be

inspected before use, and at least annual-

ly, by a qualified field service person, to

ensure that the flow of combustion and

ventilation air is not obstructed.

During the annual service call, the burners

should be removed from the burner tray

and cleaned. Replace the embers but do

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF CON- TROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UN- DER WATER.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

8)Each time the appliance is lit, it may cause condensation and fog the glass. This con- densation and fog is normal and will disap- pear in a few minutes as the glass heats up.

Never operate the appliance without the glass properly secured in place or with the door open.

9)Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner).

Note: If you have an incorrect flame pat- tern, contact your Waterford deal- er for further instructions.

Top View of pilot flame

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These compo- nents should be replaced immediately.

2)Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive conden- sation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

not block the pilot.

7) Keep the area near the appliance clear and

free from combustible materials, gasoline,

and other flammable vapours and liquids.

CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

Top View of pilot flame

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installa- tion.

Note: Improper positioning of logs may create carbon build-up and will al- ter the unit’s performance which is not covered under warranty.

Waterford TARA T25 Direct Vent Freestanding Gas Stove

31

Image 31
Contents Tara Direct Vent Freestanding Gas Stove To the New Owner WaterfordTable of Contents Copy of Safety Label for Tara T25 Gas Stove Safety LabelInformation for Mobile Manufactured Homes After First Sale InstallationSpecifications Save These InstructionsClearances to Combustibles General Safety InformationInstallation Checklist Manufactured Mobile Home Additional RequirementsLocating Your GAS Stove Optional FAN InstallationTara Clearances Installation Combustion and Ventilation AIR Exterior Vent Terminal Quired. Other parts may be required Planning Your venting InstallationFor your particular installation Minimum components for a Horizontal InstallationBelow Grade Snorkel Installation Horizontal InstallationsSnorkel Terminations Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps Qty. Description DV Stove Horizontal Vent KITDURA-VENT Termination KIT Planning Your Dura-Vent InstallationAlternate Horizontal Termination Caps Rigid Pipe Venting Components4DT-AJB Rigid Pipe Venting Components ListRigid Pipe Venting Vertical Terminations Rigid Pipe Venting Horizontal TerminationsFor both Residential & Manufactured Homes/Mobile Homes Vent Restrictor DURA-VENT Horizontal InstallationsTermination Round Support RDS Square Support SQS Offset ChartCathedral Ceilings Support Extensions Round Rdse or Square SqseConverting a Factory Built Metal Chimney Converting a Masonry ChimneySystem Data Tara T25 High ElevationValve Description GAS Pipe Pressure TestingGAS Connection Conversion KIT From Natural GAS To PropaneReplace yellow Natural Gas label with red Propane label Securing Cast Iron Front Panel Aeration AdjustmentRemoving Cast Iron Front Panel Optional Front GrillOptional Side Shelf LOG InstallationOptional Wall Thermostat Final Check Optional Remote ControlWiring Diagram Tara Thermostat Wire TableOperating Instructions Sounds LOG Replacement MaintenanceMaintenance Instructions General Vent MaintenanceInstalling Valve Assembly Glass ReplacementFAN Maintenance Valve MaintenanceReplacement / Spare Parts List Parts ListPage Conditions WarrantyRegister your Waterford online at

T25-LP, T25-NG specifications

Waterford Appliances presents the T25-LP and T25-NG, two exceptional models in the realm of gas fireplaces that combine elegance, efficiency, and advanced technology. These fireplaces are designed to create a warm and inviting ambiance in any living space, making them perfect for both modern and traditional homes.

The T25-LP (liquid propane) and T25-NG (natural gas) models feature a sleek design that seamlessly integrates into various interior settings. One of their standout characteristics is the expansive viewing area, which allows for an unobstructed view of the mesmerizing flames. The clean lines and contemporary aesthetics of the T25 series make them a striking focal point in any room.

Functional elegance is enhanced by the innovative Multi-Stage Burner System, which produces a realistic flame pattern and optimal heat output. This technology ensures that both models deliver a beautiful, natural fire while also prioritizing efficiency. With adjustable flame heights, users can customize their experience to suit their mood, whether they desire a soft glow for a cozy evening or a higher flame for more substantial heating.

Energy efficiency is another key feature of the T25 series. Both models have been designed with high-efficiency ratings, allowing homeowners to enjoy warmth without excessive energy consumption. This not only contributes to lower utility bills but also aligns with environmentally conscious living. The incorporation of electronic ignition ensures a hassle-free start-up process, with the option for a remote control that enhances convenience.

Additionally, the T25 fireplaces are equipped with advanced safety features, including a built-in pressure regulator and safety shut-off valves, providing peace of mind for users. The fireplaces also come with a range of customizable options such as decorative media, including glass and logs, allowing homeowners to tailor the look of their fireplace to their personal style.

The T25-LP and T25-NG models stand out not only for their beauty but also for their performance and reliability. With user-friendly controls and durable construction, these fireplaces provide lasting enjoyment and comfort. Waterford Appliances has engineered these units to be low-maintenance while ensuring high-end performance, making them a superior choice for anyone looking to enhance their living environment with warmth and style. Overall, with cutting-edge technology, elegant design, and user-centered functionality, the T25 series is a remarkable addition to any home.