Waterford Appliances T25-LP, T25-NG Installation, Save These Instructions, Specifications

Page 5

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The TARA Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the building author- ity having jurisdiction to determine the need for a permit prior to starting the installation.

Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or war- ranty.

Note: These instructions take prece- dence over Simpson Dura-Vent instructions.

SPECIFICATIONS

Fuels: The TARA is factory equipped for use with natural gas. A Propane Conversion Kit (#290-969) is availa- ble to convert the TARA for use with liquefied petroleum gases (propane).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 125/75 (Optional)

Log Sets: Ceramic fibre, 5 per set.

Vent System: Coaxial (6-5/8" outer / 4" inner liner) rigid flue and termination cap.

The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independent of any installed system.

INFORMATION FOR

MOBILE/

MANUFACTURED

HOMES AFTER

FIRST SALE

This Waterford product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: UL 307B- 1995, CAN/CGA-2.17-M91 and ANSI Z21.88b- 2003/CSA 2.33b-2003.

This Direct Vent System Appliance must be installed in accordance with the manufactur- er's installation instructions and the Manufac- tured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or thecurrentStandard of Fire Safety Criteria for Manufactured Home Installations,Sites,andCommunitiesANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This Waterford Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit.

This Waterford Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 18 gauge copper wire from the steel chassis ground must be attached.

This appliance may only be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only to be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a cer- tified kit is used.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIRS SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THIS APPLI- ANCE SHOULD BE INSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENT, BURNERS AND CIRCULATING AIR PASSAGEWAYS

OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

1)Provide adequate clearances for servicing, proper operation and around the air open- ings into the combustion chamber.

2)The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or it can be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, tile, wood flooring or other com- bustible material. The TARA Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner.

3)The TARA Direct Vent Freestanding Gas Stove is approved for alcove installations, which meet the clearances listed on page 6. This unit is approved for manufactured home installations, see page 6 and pages 9 to 17 for the required vent arrangements. If in- stalled into a manufactured home the unit must be bolted down to the floor.

4)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt

Waterford TARA T25 Direct Vent Freestanding Gas Stove

5

Image 5
Contents Tara Direct Vent Freestanding Gas Stove To the New Owner WaterfordTable of Contents Copy of Safety Label for Tara T25 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationManufactured Mobile Home Additional Requirements Clearances to CombustiblesTara Clearances Optional FAN InstallationLocating Your GAS Stove Installation Combustion and Ventilation AIR Exterior Vent Terminal For your particular installation Planning Your venting InstallationMinimum components for a Horizontal Installation Quired. Other parts may be requiredSnorkel Terminations Horizontal InstallationsBelow Grade Snorkel Installation Alternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemDescription Qty. Description DV Stove Horizontal Vent KITDURA-VENT Termination KIT Planning Your Dura-Vent InstallationAlternate Horizontal Termination Caps Rigid Pipe Venting Components4DT-AJB Rigid Pipe Venting Components ListFor both Residential & Manufactured Homes/Mobile Homes Rigid Pipe Venting Horizontal TerminationsRigid Pipe Venting Vertical Terminations Vent Restrictor DURA-VENT Horizontal InstallationsTermination Cathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse Round Support RDS Square Support SQSConverting a Factory Built Metal Chimney Converting a Masonry ChimneySystem Data Tara T25 High ElevationGAS Connection GAS Pipe Pressure TestingConversion KIT From Natural GAS To Propane Valve DescriptionReplace yellow Natural Gas label with red Propane label Removing Cast Iron Front Panel Aeration AdjustmentOptional Front Grill Securing Cast Iron Front PanelOptional Wall Thermostat LOG InstallationOptional Side Shelf Wiring Diagram Tara Optional Remote ControlThermostat Wire Table Final CheckOperating Instructions Sounds Maintenance Instructions MaintenanceGeneral Vent Maintenance LOG ReplacementFAN Maintenance Glass ReplacementValve Maintenance Installing Valve AssemblyReplacement / Spare Parts List Parts ListPage Conditions WarrantyRegister your Waterford online at

T25-LP, T25-NG specifications

Waterford Appliances presents the T25-LP and T25-NG, two exceptional models in the realm of gas fireplaces that combine elegance, efficiency, and advanced technology. These fireplaces are designed to create a warm and inviting ambiance in any living space, making them perfect for both modern and traditional homes.

The T25-LP (liquid propane) and T25-NG (natural gas) models feature a sleek design that seamlessly integrates into various interior settings. One of their standout characteristics is the expansive viewing area, which allows for an unobstructed view of the mesmerizing flames. The clean lines and contemporary aesthetics of the T25 series make them a striking focal point in any room.

Functional elegance is enhanced by the innovative Multi-Stage Burner System, which produces a realistic flame pattern and optimal heat output. This technology ensures that both models deliver a beautiful, natural fire while also prioritizing efficiency. With adjustable flame heights, users can customize their experience to suit their mood, whether they desire a soft glow for a cozy evening or a higher flame for more substantial heating.

Energy efficiency is another key feature of the T25 series. Both models have been designed with high-efficiency ratings, allowing homeowners to enjoy warmth without excessive energy consumption. This not only contributes to lower utility bills but also aligns with environmentally conscious living. The incorporation of electronic ignition ensures a hassle-free start-up process, with the option for a remote control that enhances convenience.

Additionally, the T25 fireplaces are equipped with advanced safety features, including a built-in pressure regulator and safety shut-off valves, providing peace of mind for users. The fireplaces also come with a range of customizable options such as decorative media, including glass and logs, allowing homeowners to tailor the look of their fireplace to their personal style.

The T25-LP and T25-NG models stand out not only for their beauty but also for their performance and reliability. With user-friendly controls and durable construction, these fireplaces provide lasting enjoyment and comfort. Waterford Appliances has engineered these units to be low-maintenance while ensuring high-end performance, making them a superior choice for anyone looking to enhance their living environment with warmth and style. Overall, with cutting-edge technology, elegant design, and user-centered functionality, the T25 series is a remarkable addition to any home.