MAINTENANCE

GLASS

REPLACEMENT

Your TARA stove is supplied with high temper- ature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement door from an authorized Waterford dealer only, and follow our step-by-step instructions for re- placement.

Replacement Part # W260040 Tara Glass

WARNING: Do not operate appliance with glass panels removed, cracked or bro- ken. Replacement of the glass should be done by a licensed or qualified service person.

Note: Wearing gloves will protect your hands while handling glass.

1)Remove the cast iron front panel, grasp it at the bottom and lift the panel upwards and out from the stove. Once free of the locating tabs, the panel can be dropped down; freeing it from the top of the stove.

Place the cast iron front panel on a non- abrasive surface, away from any traffic to ensure that it does not get damaged.

2)Remove the Front Glass Panel. Using a 7/16" socket wrench, remove the 6 hex head bolts used to secure the glass panel and frame to the stove. Remove the frame and glass panel.

3)Using a flat screwdriver, pry open the 4 retaining tabs holding the glass panel in place and remove the old glass.

5)Insert the glass (with gasket) in to the frame so that the 'bulb' portion of the gasket is exposed.

6)Using a flat screwdriver, close the 4 retain- ing tabs used to hold the glass in place.

7)Replace the Front Glass Panel on the stove and reinstall the Cast Iron Front Panel.

FAN MAINTENANCE

If your fan requires maintenance or replace- ment, access to the fan is through the rear access panel on the back of the unit. NOTE:the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan mo- tors on a regular basis by vacuum- ing out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

IMPORTANT

Disconnect power supply

before servicing

VALVE MAINTENANCE

If your valve requires maintenance or replace- ment, use the following instructions.

Note: Always close off the gas supply

before removing the valve.

1)If optional fan is installed, disconnect power source to stove.

2)Remove control panel.

3)Disconnect gas line to stove.

4)Disconnect 3/8" NPT pipe from 90o elbow on valve.

5)Disconnect the two (2) switch wires from valve.

6)Disconnect piezo wire.

7)Remove the cast iron front panel for easier access.

8) Remove the 4 screws holding the gas valve assembly to the bracket.

9) Remove the thermopile wire.

10) Remove thermocouple with a 9 mm (met-

ric) wrench.

11) Remove pilot nut with an 11 mm wrench.

12) Remove valve to orifice nut with a 13/16"

wrench.

13) Remove inlet pipe with pipe wrench. Note

orientation of 90o elbow.

4)Take the new glass and fit the 'tadpole' glass gasket around the edge of the glass.

WARNING:

Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock haz- ard and should be plugged direct- ly into a properly grounded three- prong receptacle. Do not cut or remove the grounding prong from this plug.

To remove fan: Follow the

installation in- structions on page 7 in re- verse.

14) Remove valve and remove gas out 90o

brass fitting. Note orientation of fitting.

Installing Valve Assembly

1)To install a new valve assembly, reverse instructions for removing valve . See above.

2)Check for leaks and manifold pressure. See Gas Pressure Test instructions.

Screw

Screw

Screw

Screw

Stove Front

Valve Bracket with Valve - Top View

32

Waterford TARA T25 Direct Vent Freestanding Gas Stove

Image 32
Contents Tara Direct Vent Freestanding Gas Stove Waterford To the New OwnerTable of Contents Safety Label Copy of Safety Label for Tara T25 Gas StoveInstallation SpecificationsSave These Instructions Information for Mobile Manufactured Homes After First SaleGeneral Safety Information Installation ChecklistManufactured Mobile Home Additional Requirements Clearances to CombustiblesTara Clearances Optional FAN InstallationLocating Your GAS Stove Installation Combustion and Ventilation AIR Exterior Vent Terminal Planning Your venting Installation For your particular installationMinimum components for a Horizontal Installation Quired. Other parts may be requiredSnorkel Terminations Horizontal InstallationsBelow Grade Snorkel Installation Alternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemDescription DV Stove Horizontal Vent KIT Qty. DescriptionPlanning Your Dura-Vent Installation DURA-VENT Termination KITRigid Pipe Venting Components Alternate Horizontal Termination CapsRigid Pipe Venting Components List 4DT-AJBFor both Residential & Manufactured Homes/Mobile Homes Rigid Pipe Venting Horizontal TerminationsRigid Pipe Venting Vertical Terminations DURA-VENT Horizontal Installations Vent RestrictorTermination Offset Chart Cathedral CeilingsSupport Extensions Round Rdse or Square Sqse Round Support RDS Square Support SQSConverting a Masonry Chimney Converting a Factory Built Metal ChimneyHigh Elevation System Data Tara T25GAS Pipe Pressure Testing GAS ConnectionConversion KIT From Natural GAS To Propane Valve DescriptionReplace yellow Natural Gas label with red Propane label Aeration Adjustment Removing Cast Iron Front PanelOptional Front Grill Securing Cast Iron Front PanelOptional Wall Thermostat LOG InstallationOptional Side Shelf Optional Remote Control Wiring Diagram TaraThermostat Wire Table Final CheckOperating Instructions Sounds Maintenance Maintenance InstructionsGeneral Vent Maintenance LOG ReplacementGlass Replacement FAN MaintenanceValve Maintenance Installing Valve AssemblyParts List Replacement / Spare Parts ListPage Warranty ConditionsRegister your Waterford online at

T25-LP, T25-NG specifications

Waterford Appliances presents the T25-LP and T25-NG, two exceptional models in the realm of gas fireplaces that combine elegance, efficiency, and advanced technology. These fireplaces are designed to create a warm and inviting ambiance in any living space, making them perfect for both modern and traditional homes.

The T25-LP (liquid propane) and T25-NG (natural gas) models feature a sleek design that seamlessly integrates into various interior settings. One of their standout characteristics is the expansive viewing area, which allows for an unobstructed view of the mesmerizing flames. The clean lines and contemporary aesthetics of the T25 series make them a striking focal point in any room.

Functional elegance is enhanced by the innovative Multi-Stage Burner System, which produces a realistic flame pattern and optimal heat output. This technology ensures that both models deliver a beautiful, natural fire while also prioritizing efficiency. With adjustable flame heights, users can customize their experience to suit their mood, whether they desire a soft glow for a cozy evening or a higher flame for more substantial heating.

Energy efficiency is another key feature of the T25 series. Both models have been designed with high-efficiency ratings, allowing homeowners to enjoy warmth without excessive energy consumption. This not only contributes to lower utility bills but also aligns with environmentally conscious living. The incorporation of electronic ignition ensures a hassle-free start-up process, with the option for a remote control that enhances convenience.

Additionally, the T25 fireplaces are equipped with advanced safety features, including a built-in pressure regulator and safety shut-off valves, providing peace of mind for users. The fireplaces also come with a range of customizable options such as decorative media, including glass and logs, allowing homeowners to tailor the look of their fireplace to their personal style.

The T25-LP and T25-NG models stand out not only for their beauty but also for their performance and reliability. With user-friendly controls and durable construction, these fireplaces provide lasting enjoyment and comfort. Waterford Appliances has engineered these units to be low-maintenance while ensuring high-end performance, making them a superior choice for anyone looking to enhance their living environment with warmth and style. Overall, with cutting-edge technology, elegant design, and user-centered functionality, the T25 series is a remarkable addition to any home.