10
Waterford TARA T25 Direct Vent Freestanding Gas Stove
|
|
| EXTERIOR VENT TERMINAL |
A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) | H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally from | LOCATIONS | |
| |||
B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) |
| the centerline of the regulator. |
|
C= Clearance to permanently closed window *(min. 12"/30cm) | J= | Clearance to service regulator vent outlet *(min. 36"/90cm) |
|
D= Vertical clearance to ventilated soffit located above the terminal within a horizontal | K= Clearance to |
| |
distance of (24"/60cm) from the centerline of the terminal (min. 18"/46cm) check with |
| any other appliance *(12"/30cm) #(9"/23cm) |
|
local code. | L= | Clearance to a mechanical air supply inlet *(min. 72"/1.8m) |
|
E= Clearance to unventilated soffit (min. 12"/30cm) |
| #3' (91cm) above if within 10' (3m) horizontally. |
|
F= Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm), with | M= **Clearance above paved sidewalk or a paved driveway located on public property |
| |
| *(min. 84"/2.1m) |
| |
G= Clearance to inside corner: withAstroCapTermination Cap (min. 6"/15cm), with Dura- | N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)*** |
| |
Vent Termination Cap (12"/30cm) |
|
|
|
Note: * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.
**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. #In accordance with the current ANSI Z223.1 / NFPA 54, National Fuel Gas Code.