Waterford Appliances T25-LP, T25-NG Replace yellow Natural Gas label with red Propane label

Page 25

INSTALLATION

NOTE: If the conversion to Propane is being made at the time of installation, the valve may be removed to make it more accessible.

1)Shut off the gas supply.

2)Remove the Cast Iron Front Panel. Hold the cast iron front panel at the bottom and lift upwards and out from the stove. Once free of the locating tabs, the panel can be dropped down; freeing it from the top of the stove.

Place the cast iron front panel on a non- abrasive surface, away from any traffic to ensure that it does not get damaged.

3)Remove the Front Glass Panel. Using a 7/ 16" socket wrench, remove the 6hex head bolts used to secure the glass panel and frame to the stove. Remove the frame and

glass panel and set it aside.

4)Remove the logs.

5)Remove the burner tube by removing the locking screw on the rear burner support bracket and then lift the burner out.

6)Using a 1/2" deep socket remove the burner orifice and install new front burner orifice LP stamped #53 and tighten.

7)Pull off the pilot cap to expose the pilot orifice.

8)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit.

9)Replace the burner. Place the burner onto the support bracket and guide the front of the burner onto the burner injector. The burner air shutter gears must be aligned. Check to make sure that the two gears engage each other by at least two-thirds of their thickness. If not, it will be necessary to disengage the burner and screw the drive gear in and out as required. Once everything is aligned properly, secure the burner with the locking screw.

10)Re-install the logs, front glass panel and cast iron door front.

11)Remove and discard the 3 pressure regu- lator mounting screws (A), pressure reg- ulator tower (B) and diaphragm (C).

12)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.

13)Attach clear label "This unit has been con- verted to Propane" on the serial # decal.

14)Replace yellow "Natural Gas" label with red "Propane" label.

15)Take the Decal with the Propane Orifice #, Manifold Pressure, Input, etc. and attach to

the stove's rear heat shield to indicate that the unit has been converted to burn pro- pane.

16)Check for gas leaks.

17)Check inlet and outlet pressures.

18)Check operation of flame control.

19)Check for proper flame appearance and glow on logs.

Waterford TARA T25 Direct Vent Freestanding Gas Stove

25

Image 25
Contents Tara Direct Vent Freestanding Gas Stove To the New Owner WaterfordTable of Contents Copy of Safety Label for Tara T25 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationManufactured Mobile Home Additional Requirements Clearances to CombustiblesLocating Your GAS Stove Optional FAN InstallationTara Clearances Installation Combustion and Ventilation AIR Exterior Vent Terminal For your particular installation Planning Your venting InstallationMinimum components for a Horizontal Installation Quired. Other parts may be requiredBelow Grade Snorkel Installation Horizontal InstallationsSnorkel Terminations Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps Qty. Description DV Stove Horizontal Vent KITDURA-VENT Termination KIT Planning Your Dura-Vent InstallationAlternate Horizontal Termination Caps Rigid Pipe Venting Components4DT-AJB Rigid Pipe Venting Components ListRigid Pipe Venting Vertical Terminations Rigid Pipe Venting Horizontal TerminationsFor both Residential & Manufactured Homes/Mobile Homes Vent Restrictor DURA-VENT Horizontal InstallationsTermination Cathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse Round Support RDS Square Support SQS Converting a Factory Built Metal Chimney Converting a Masonry ChimneySystem Data Tara T25 High ElevationGAS Connection GAS Pipe Pressure TestingConversion KIT From Natural GAS To Propane Valve DescriptionReplace yellow Natural Gas label with red Propane label Removing Cast Iron Front Panel Aeration AdjustmentOptional Front Grill Securing Cast Iron Front PanelOptional Side Shelf LOG InstallationOptional Wall Thermostat Wiring Diagram Tara Optional Remote ControlThermostat Wire Table Final CheckOperating Instructions Sounds Maintenance Instructions MaintenanceGeneral Vent Maintenance LOG ReplacementFAN Maintenance Glass ReplacementValve Maintenance Installing Valve AssemblyReplacement / Spare Parts List Parts ListPage Conditions WarrantyRegister your Waterford online at