Waterford Appliances T25-LP, T25-NG Replace yellow Natural Gas label with red Propane label

Page 25

INSTALLATION

NOTE: If the conversion to Propane is being made at the time of installation, the valve may be removed to make it more accessible.

1)Shut off the gas supply.

2)Remove the Cast Iron Front Panel. Hold the cast iron front panel at the bottom and lift upwards and out from the stove. Once free of the locating tabs, the panel can be dropped down; freeing it from the top of the stove.

Place the cast iron front panel on a non- abrasive surface, away from any traffic to ensure that it does not get damaged.

3)Remove the Front Glass Panel. Using a 7/ 16" socket wrench, remove the 6hex head bolts used to secure the glass panel and frame to the stove. Remove the frame and

glass panel and set it aside.

4)Remove the logs.

5)Remove the burner tube by removing the locking screw on the rear burner support bracket and then lift the burner out.

6)Using a 1/2" deep socket remove the burner orifice and install new front burner orifice LP stamped #53 and tighten.

7)Pull off the pilot cap to expose the pilot orifice.

8)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit.

9)Replace the burner. Place the burner onto the support bracket and guide the front of the burner onto the burner injector. The burner air shutter gears must be aligned. Check to make sure that the two gears engage each other by at least two-thirds of their thickness. If not, it will be necessary to disengage the burner and screw the drive gear in and out as required. Once everything is aligned properly, secure the burner with the locking screw.

10)Re-install the logs, front glass panel and cast iron door front.

11)Remove and discard the 3 pressure regu- lator mounting screws (A), pressure reg- ulator tower (B) and diaphragm (C).

12)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.

13)Attach clear label "This unit has been con- verted to Propane" on the serial # decal.

14)Replace yellow "Natural Gas" label with red "Propane" label.

15)Take the Decal with the Propane Orifice #, Manifold Pressure, Input, etc. and attach to

the stove's rear heat shield to indicate that the unit has been converted to burn pro- pane.

16)Check for gas leaks.

17)Check inlet and outlet pressures.

18)Check operation of flame control.

19)Check for proper flame appearance and glow on logs.

Waterford TARA T25 Direct Vent Freestanding Gas Stove

25

Image 25
Contents Tara Direct Vent Freestanding Gas Stove To the New Owner WaterfordTable of Contents Copy of Safety Label for Tara T25 Gas Stove Safety LabelSpecifications InstallationSave These Instructions Information for Mobile Manufactured Homes After First SaleInstallation Checklist General Safety InformationManufactured Mobile Home Additional Requirements Clearances to CombustiblesLocating Your GAS Stove Optional FAN InstallationTara Clearances Installation Combustion and Ventilation AIR Exterior Vent Terminal For your particular installation Planning Your venting InstallationMinimum components for a Horizontal Installation Quired. Other parts may be requiredBelow Grade Snorkel Installation Horizontal InstallationsSnorkel Terminations Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps Qty. Description DV Stove Horizontal Vent KITDURA-VENT Termination KIT Planning Your Dura-Vent InstallationAlternate Horizontal Termination Caps Rigid Pipe Venting Components4DT-AJB Rigid Pipe Venting Components ListRigid Pipe Venting Vertical Terminations Rigid Pipe Venting Horizontal TerminationsFor both Residential & Manufactured Homes/Mobile Homes Vent Restrictor DURA-VENT Horizontal InstallationsTermination Cathedral Ceilings Offset ChartSupport Extensions Round Rdse or Square Sqse Round Support RDS Square Support SQSConverting a Factory Built Metal Chimney Converting a Masonry ChimneySystem Data Tara T25 High ElevationGAS Connection GAS Pipe Pressure TestingConversion KIT From Natural GAS To Propane Valve DescriptionReplace yellow Natural Gas label with red Propane label Removing Cast Iron Front Panel Aeration AdjustmentOptional Front Grill Securing Cast Iron Front PanelOptional Side Shelf LOG InstallationOptional Wall Thermostat Wiring Diagram Tara Optional Remote ControlThermostat Wire Table Final CheckOperating Instructions Sounds Maintenance Instructions MaintenanceGeneral Vent Maintenance LOG ReplacementFAN Maintenance Glass ReplacementValve Maintenance Installing Valve AssemblyReplacement / Spare Parts List Parts ListPage Conditions WarrantyRegister your Waterford online at

T25-LP, T25-NG specifications

Waterford Appliances presents the T25-LP and T25-NG, two exceptional models in the realm of gas fireplaces that combine elegance, efficiency, and advanced technology. These fireplaces are designed to create a warm and inviting ambiance in any living space, making them perfect for both modern and traditional homes.

The T25-LP (liquid propane) and T25-NG (natural gas) models feature a sleek design that seamlessly integrates into various interior settings. One of their standout characteristics is the expansive viewing area, which allows for an unobstructed view of the mesmerizing flames. The clean lines and contemporary aesthetics of the T25 series make them a striking focal point in any room.

Functional elegance is enhanced by the innovative Multi-Stage Burner System, which produces a realistic flame pattern and optimal heat output. This technology ensures that both models deliver a beautiful, natural fire while also prioritizing efficiency. With adjustable flame heights, users can customize their experience to suit their mood, whether they desire a soft glow for a cozy evening or a higher flame for more substantial heating.

Energy efficiency is another key feature of the T25 series. Both models have been designed with high-efficiency ratings, allowing homeowners to enjoy warmth without excessive energy consumption. This not only contributes to lower utility bills but also aligns with environmentally conscious living. The incorporation of electronic ignition ensures a hassle-free start-up process, with the option for a remote control that enhances convenience.

Additionally, the T25 fireplaces are equipped with advanced safety features, including a built-in pressure regulator and safety shut-off valves, providing peace of mind for users. The fireplaces also come with a range of customizable options such as decorative media, including glass and logs, allowing homeowners to tailor the look of their fireplace to their personal style.

The T25-LP and T25-NG models stand out not only for their beauty but also for their performance and reliability. With user-friendly controls and durable construction, these fireplaces provide lasting enjoyment and comfort. Waterford Appliances has engineered these units to be low-maintenance while ensuring high-end performance, making them a superior choice for anyone looking to enhance their living environment with warmth and style. Overall, with cutting-edge technology, elegant design, and user-centered functionality, the T25 series is a remarkable addition to any home.