INSTALLATION

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

 

Wire Size

Max. Length

 

 

 

 

 

 

 

14 GA.

50

Ft.

 

16 GA.

32

Ft.

 

 

18 GA.

20

Ft.

 

20 GA.

12

Ft.

 

22 GA.

9

Ft.

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONAL REMOTE

CONTROL

Use the Waterford Remote Control Kits ap- proved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very im- portant). Run wires from the fireplace to that location, use Thermostat Wire Table.

2)Connect the wires as per the wiring dia- gram below.

CAUTION

Do not connect the millivolt remote control wires to the 120V wires.

3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:

1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.

WIRING DIAGRAM - TARA

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. If any of the original wires as supplied with the appliance must be replaced, it must be replaced with CSA type SEW-2 (200oC) or its equivalent.

Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring er- rors can cause improper and dangerous operation.

28

Waterford TARA T25 Direct Vent Freestanding Gas Stove

Image 28
Contents Tara Direct Vent Freestanding Gas Stove Waterford To the New OwnerTable of Contents Safety Label Copy of Safety Label for Tara T25 Gas StoveInstallation SpecificationsSave These Instructions Information for Mobile Manufactured Homes After First SaleGeneral Safety Information Installation ChecklistManufactured Mobile Home Additional Requirements Clearances to CombustiblesLocating Your GAS Stove Optional FAN InstallationTara Clearances Installation Combustion and Ventilation AIR Exterior Vent Terminal Planning Your venting Installation For your particular installationMinimum components for a Horizontal Installation Quired. Other parts may be requiredBelow Grade Snorkel Installation Horizontal InstallationsSnorkel Terminations Description Vertical Termination with CO-LINEAR Flex SystemAlternate Approved Caps DV Stove Horizontal Vent KIT Qty. DescriptionPlanning Your Dura-Vent Installation DURA-VENT Termination KITRigid Pipe Venting Components Alternate Horizontal Termination CapsRigid Pipe Venting Components List 4DT-AJBRigid Pipe Venting Vertical Terminations Rigid Pipe Venting Horizontal TerminationsFor both Residential & Manufactured Homes/Mobile Homes DURA-VENT Horizontal Installations Vent RestrictorTermination Offset Chart Cathedral CeilingsSupport Extensions Round Rdse or Square Sqse Round Support RDS Square Support SQSConverting a Masonry Chimney Converting a Factory Built Metal ChimneyHigh Elevation System Data Tara T25GAS Pipe Pressure Testing GAS ConnectionConversion KIT From Natural GAS To Propane Valve DescriptionReplace yellow Natural Gas label with red Propane label Aeration Adjustment Removing Cast Iron Front PanelOptional Front Grill Securing Cast Iron Front PanelOptional Side Shelf LOG InstallationOptional Wall Thermostat Optional Remote Control Wiring Diagram TaraThermostat Wire Table Final CheckOperating Instructions Sounds Maintenance Maintenance InstructionsGeneral Vent Maintenance LOG ReplacementGlass Replacement FAN MaintenanceValve Maintenance Installing Valve AssemblyParts List Replacement / Spare Parts ListPage Warranty ConditionsRegister your Waterford online at

T25-LP, T25-NG specifications

Waterford Appliances presents the T25-LP and T25-NG, two exceptional models in the realm of gas fireplaces that combine elegance, efficiency, and advanced technology. These fireplaces are designed to create a warm and inviting ambiance in any living space, making them perfect for both modern and traditional homes.

The T25-LP (liquid propane) and T25-NG (natural gas) models feature a sleek design that seamlessly integrates into various interior settings. One of their standout characteristics is the expansive viewing area, which allows for an unobstructed view of the mesmerizing flames. The clean lines and contemporary aesthetics of the T25 series make them a striking focal point in any room.

Functional elegance is enhanced by the innovative Multi-Stage Burner System, which produces a realistic flame pattern and optimal heat output. This technology ensures that both models deliver a beautiful, natural fire while also prioritizing efficiency. With adjustable flame heights, users can customize their experience to suit their mood, whether they desire a soft glow for a cozy evening or a higher flame for more substantial heating.

Energy efficiency is another key feature of the T25 series. Both models have been designed with high-efficiency ratings, allowing homeowners to enjoy warmth without excessive energy consumption. This not only contributes to lower utility bills but also aligns with environmentally conscious living. The incorporation of electronic ignition ensures a hassle-free start-up process, with the option for a remote control that enhances convenience.

Additionally, the T25 fireplaces are equipped with advanced safety features, including a built-in pressure regulator and safety shut-off valves, providing peace of mind for users. The fireplaces also come with a range of customizable options such as decorative media, including glass and logs, allowing homeowners to tailor the look of their fireplace to their personal style.

The T25-LP and T25-NG models stand out not only for their beauty but also for their performance and reliability. With user-friendly controls and durable construction, these fireplaces provide lasting enjoyment and comfort. Waterford Appliances has engineered these units to be low-maintenance while ensuring high-end performance, making them a superior choice for anyone looking to enhance their living environment with warmth and style. Overall, with cutting-edge technology, elegant design, and user-centered functionality, the T25 series is a remarkable addition to any home.