Waterford Appliances T25-LP, T25-NG installation manual High Elevation, System Data Tara T25

Page 23

INSTALLATION

Diagram 7

4)To determine the length of flex required, measure from 3" (76mm) above the top of the Flashing down to the level of the open- ing. Add to this measurement the distance from the center of the chimney to out through the wall. Cut a piece of 4" flex to this length (the flex should already be extended to its nominal length).

5)Connect the 4" flex liner to the Top Adaptor (Part # 985K) using 3 sheet metal screws. Diagram 2.

6)Feed the 4" flex liner through the Flashing into the chimney. Continue to feed the liner out through the opening in the masonry wall.

7)Secure the Top Adaptor to the Flashing. Use 3 sheet metal screws through the side of the adaptor into the flange on the Flashing (diagram 8). Twist lock the Termination Cap (Part # 980 or 991) on to the Top Adaptor.

Diagram 8

8)Attach the flex to the Retro Connector. Use 3 sheet metal screws to attach the flex liner to the Connector. Diagram 9. Mount the Retro Connector to the masonry wall using masonry bolts. Re-drill larger holes on con- nector as needed. Be careful to insure that the connector is centered in the opening and the mounting holes line up with the masonry wall.

Diagram 9

9)Slide the Wall Thimble Cover (Part # 940) over the Retro Connector and secure with masonry bolts. Diagram 10. If you have a framed wall in front of the masonry, use wood screws to mount the Wall Thimble Cover to the framed wall, over the Retro Connector and the 10" (254mm) square framed opening. Diagram 11. If needed, add a section of direct vent pipe to the Retro Connector in order to extend through the opening in the Wall Thimble Cover.

Diagram 10

Diagram 11

10)The connection between the appliance and the Retro Connector may be completed with a section of black direct vent pipe, together with an adjustable length pipe section.

HIGH ELEVATION

This unit is approved in Canada for altitude to4500 ft. (CAN/CGA-2.17-M91) with theresized orifice. For Natural Gas installations above 4500 ft. follow current CAN/CGA-B149.1.

In U.S.A., for installations above 2000 ft. refer to current ANSI Z223.1 Sc8-8.1.2a appendix F, for resizing orifice.

System Data - TARA T25

 

For 0 to 4500 feet altitude

 

 

 

Burner Inlet Orifice Sizes:

 

 

 

Natural Gas

Propane

 

 

Burner

#41

 

#53

 

 

 

 

 

 

 

Max. Input Rating

 

 

 

 

- Natural Gas

 

25,000 Btu/h

 

 

- Propane

 

25,000 Btu/h

 

 

Min. Input Rating

 

 

 

 

- Natural Gas

 

15,000 Btu/h

 

 

- Propane

 

13,000 Btu/h

 

 

 

 

 

 

 

Output Capacity

 

 

 

 

Natural Gas

 

18,875 Btu/h

 

 

Propane

 

19,250 Btu/h

 

 

 

 

 

 

 

Supply Pressure

 

 

 

 

Natural Gas

 

min.

5.0" w.c.

 

 

Propane

 

min.

12.0" w.c.

 

 

 

 

 

 

 

Manifold Pressure

 

 

 

 

Natural Gas

 

3.8"

+/- 0.2" w.c.

 

 

Propane

 

11"

+/- 0.2" w.c.

 

Waterford TARA T25 Direct Vent Freestanding Gas Stove

23

Image 23
Contents Tara Direct Vent Freestanding Gas Stove To the New Owner WaterfordTable of Contents Copy of Safety Label for Tara T25 Gas Stove Safety LabelInformation for Mobile Manufactured Homes After First Sale InstallationSpecifications Save These InstructionsClearances to Combustibles General Safety InformationInstallation Checklist Manufactured Mobile Home Additional RequirementsTara Clearances Optional FAN InstallationLocating Your GAS Stove Installation Combustion and Ventilation AIR Exterior Vent Terminal Quired. Other parts may be required Planning Your venting InstallationFor your particular installation Minimum components for a Horizontal InstallationSnorkel Terminations Horizontal InstallationsBelow Grade Snorkel Installation Alternate Approved Caps Vertical Termination with CO-LINEAR Flex SystemDescription Qty. Description DV Stove Horizontal Vent KITDURA-VENT Termination KIT Planning Your Dura-Vent InstallationAlternate Horizontal Termination Caps Rigid Pipe Venting Components4DT-AJB Rigid Pipe Venting Components ListFor both Residential & Manufactured Homes/Mobile Homes Rigid Pipe Venting Horizontal TerminationsRigid Pipe Venting Vertical Terminations Vent Restrictor DURA-VENT Horizontal InstallationsTermination Round Support RDS Square Support SQS Offset ChartCathedral Ceilings Support Extensions Round Rdse or Square SqseConverting a Factory Built Metal Chimney Converting a Masonry ChimneySystem Data Tara T25 High ElevationValve Description GAS Pipe Pressure TestingGAS Connection Conversion KIT From Natural GAS To PropaneReplace yellow Natural Gas label with red Propane label Securing Cast Iron Front Panel Aeration AdjustmentRemoving Cast Iron Front Panel Optional Front GrillOptional Wall Thermostat LOG InstallationOptional Side Shelf Final Check Optional Remote ControlWiring Diagram Tara Thermostat Wire TableOperating Instructions Sounds LOG Replacement MaintenanceMaintenance Instructions General Vent MaintenanceInstalling Valve Assembly Glass ReplacementFAN Maintenance Valve MaintenanceReplacement / Spare Parts List Parts ListPage Conditions WarrantyRegister your Waterford online at

T25-LP, T25-NG specifications

Waterford Appliances presents the T25-LP and T25-NG, two exceptional models in the realm of gas fireplaces that combine elegance, efficiency, and advanced technology. These fireplaces are designed to create a warm and inviting ambiance in any living space, making them perfect for both modern and traditional homes.

The T25-LP (liquid propane) and T25-NG (natural gas) models feature a sleek design that seamlessly integrates into various interior settings. One of their standout characteristics is the expansive viewing area, which allows for an unobstructed view of the mesmerizing flames. The clean lines and contemporary aesthetics of the T25 series make them a striking focal point in any room.

Functional elegance is enhanced by the innovative Multi-Stage Burner System, which produces a realistic flame pattern and optimal heat output. This technology ensures that both models deliver a beautiful, natural fire while also prioritizing efficiency. With adjustable flame heights, users can customize their experience to suit their mood, whether they desire a soft glow for a cozy evening or a higher flame for more substantial heating.

Energy efficiency is another key feature of the T25 series. Both models have been designed with high-efficiency ratings, allowing homeowners to enjoy warmth without excessive energy consumption. This not only contributes to lower utility bills but also aligns with environmentally conscious living. The incorporation of electronic ignition ensures a hassle-free start-up process, with the option for a remote control that enhances convenience.

Additionally, the T25 fireplaces are equipped with advanced safety features, including a built-in pressure regulator and safety shut-off valves, providing peace of mind for users. The fireplaces also come with a range of customizable options such as decorative media, including glass and logs, allowing homeowners to tailor the look of their fireplace to their personal style.

The T25-LP and T25-NG models stand out not only for their beauty but also for their performance and reliability. With user-friendly controls and durable construction, these fireplaces provide lasting enjoyment and comfort. Waterford Appliances has engineered these units to be low-maintenance while ensuring high-end performance, making them a superior choice for anyone looking to enhance their living environment with warmth and style. Overall, with cutting-edge technology, elegant design, and user-centered functionality, the T25 series is a remarkable addition to any home.