Regency U32S-NG5 General Vent Maintenance, Door Glass, Glass Gasket, Top View of pilot flame

Page 24
MAINTENANCE

MAINTENANCE

Top View of pilot flame

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear of the burner or thermopile.

Top View of pilot flame

If you have an incorrect flame pattern, contact your FPI dealer for further instructions.

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.

2)Remove the Termination Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation,suchaswaterdropletsforming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

DOOR GLASS

Your FPI insert is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, and follow our step-by-step instructions for replacement.

Warning: Do not operate appliance with glass panels removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Caution: Wear gloves when removing damaged or broken glass.

Flush Glass Replacement

Remove the flush door front (as per instructions in section "Standard Flush Door"). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame.

GLASS GASKET

If the glass gasket requires replacement use glass gasket (Part # 936-155).

24

U32S-5 FPI Direct Vent Gas Insert

Image 24
Contents Installation Manual U32 Sunrise Gas InsertOwners 918-788TO THE NEW OWNER TABLE OF CONTENTS SAFETY LABELMAINTENANCE PARTS LISTSAFETY LABEL REQUIREMENTS MA Code - CO Detectorfor the State of Massachusetts only 5.08 Modifications to NFPA-54,ChapterUNIT DIMENSIONS U32S-5FPI Direct Vent Gas InsertINSTALLATION FOR YOUR SAFETYSPECIFICATIONS GAS PRESSURE TESTINGINSTALLATION INSTALLATION CHECKLISTMINIMUM FIREPLACE DIMENSIONS MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTSINSTALLATION GAS CONNECTIONVENTING COMBUSTIBLE MANTELINSTALLATION FLUE LINER INSTALLATIONGAS PIPE PRESSURE TESTING GAS INSERT AERATION SYSTEMINSTALLATION U32S-5using SIT 820 NOVA Gas ValveCONVERSION KIT # 434-969FROM NG TO LP IF IN DOUBT DO NOT DO THIS CONVERSIONINSTALLATION Installer NoticeDo not overtighten the screw. Recommended to grip the wrench by the short sideINSTALLATION Installation of the DC SparkerIgnitor Wire Piezo Ignitor Ground wire from kitINSTALLATION OPTIONAL REMOTE CONTROLto the 120V wires Thermostat Wire Table remote control the 120V wiresINSTALLATION WIRING DIAGRAMSCAUTION Label all wires prior to disconnection when servicingINSTALLATION INSTALLATION INSTALLATION ON BURNERGLASS CRYSTAL OR OPTIONAL CERAMIC STONES Minimum Air shutter OpeningINSTALLATION Diagram Diagram 1a Diagram 1b DiagramSTANDARD FLUSH DOOR INSTALLATION FACEPLATE AND DOOR FRAME INSTALLATIONKit# 425-914Contents List Door FrameINSTALLATION Completed Faceplate & Door Frame Installation8Lower the door frame gently into place 10Slide unit into final positionINSTALLATION OPTIONAL HEARTH TRIM INSTALLATION2 Hearth Trim Installation 4 Hearth Trim InstallationOPERATING INSTRUCTIONS LIGHTING PROCEDURESHUTDOWN PROCEDURE OPERATING INSTRUCTIONSMAINTENANCE INSTRUCTIONS OPERATING INSTRUCTIONSCOPY OF LIGHTING INSTRUCTION PLATE DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE GENERAL VENT MAINTENANCEDOOR GLASS GLASS GASKETMAINTENANCE FAN MAINTENANCEFAN REMOVAL BurnerMAINTENANCE Fan access platePilot assembly wires Base CoverMAINTENANCE REPLACING THE FANMAINTENANCE VALVE ASSEMBLY REPLACEMENTON/OFF Wires BurnerMAINTENANCE 11Slightly lift out valve tray12 Disconnect the inlet gas line U32S-5FPI Direct Vent Gas InsertPARTS LIST MAIN ASSEMBLYDescription PARTS LIST BURNER ASSEMBLYDescription 4 10 11 9 13PARTS LIST 1425-512Door Bottom Assembly 2425-513Frame InsideFACEPLATE AND DOORFRAME 3425-514Faceplate Outside 4425-942Hearth TrimU32S-5FPI Direct Vent Gas Insert U32S-5FPI Direct Vent Gas Insert WARRANTY The Warranty Limited LifetimeConditions ExclusionsSee the inside back cover for details