Regency U32S-NG5, U32S-LP5 installation manual Safety Label

Page 4
SAFETY LABEL

SAFETY LABEL

This is a copy of the label that accompanies each U32S-5 Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened.

NOTE: FPI units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

4

U32S-5 FPI Direct Vent Gas Insert

Image 4
Contents Installation Manual U32 Sunrise Gas InsertOwners 918-788TO THE NEW OWNER TABLE OF CONTENTS SAFETY LABELMAINTENANCE PARTS LISTSAFETY LABEL REQUIREMENTS MA Code - CO Detectorfor the State of Massachusetts only 5.08 Modifications to NFPA-54,ChapterUNIT DIMENSIONS U32S-5FPI Direct Vent Gas InsertINSTALLATION FOR YOUR SAFETYSPECIFICATIONS GAS PRESSURE TESTINGINSTALLATION INSTALLATION CHECKLISTMINIMUM FIREPLACE DIMENSIONS MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTSINSTALLATION GAS CONNECTIONVENTING COMBUSTIBLE MANTELINSTALLATION FLUE LINER INSTALLATIONGAS PIPE PRESSURE TESTING GAS INSERT AERATION SYSTEMINSTALLATION U32S-5using SIT 820 NOVA Gas ValveCONVERSION KIT # 434-969FROM NG TO LP IF IN DOUBT DO NOT DO THIS CONVERSIONINSTALLATION Installer NoticeDo not overtighten the screw. Recommended to grip the wrench by the short sideINSTALLATION Installation of the DC SparkerIgnitor Wire Piezo Ignitor Ground wire from kitINSTALLATION OPTIONAL REMOTE CONTROLto the 120V wires Thermostat Wire Table remote control the 120V wiresINSTALLATION WIRING DIAGRAMSCAUTION Label all wires prior to disconnection when servicingINSTALLATION INSTALLATION INSTALLATION ON BURNERGLASS CRYSTAL OR OPTIONAL CERAMIC STONES Minimum Air shutter OpeningDiagram Diagram 1a Diagram 1b Diagram INSTALLATIONSTANDARD FLUSH DOOR INSTALLATION FACEPLATE AND DOOR FRAME INSTALLATIONKit# 425-914Contents List Door FrameINSTALLATION Completed Faceplate & Door Frame Installation8Lower the door frame gently into place 10Slide unit into final positionINSTALLATION OPTIONAL HEARTH TRIM INSTALLATION2 Hearth Trim Installation 4 Hearth Trim InstallationOPERATING INSTRUCTIONS LIGHTING PROCEDURESHUTDOWN PROCEDURE OPERATING INSTRUCTIONSMAINTENANCE INSTRUCTIONS OPERATING INSTRUCTIONSCOPY OF LIGHTING INSTRUCTION PLATE DO NOT REMOVE THIS INSTRUCTION PLATEMAINTENANCE GENERAL VENT MAINTENANCEDOOR GLASS GLASS GASKETMAINTENANCE FAN MAINTENANCEFAN REMOVAL BurnerMAINTENANCE Fan access platePilot assembly wires Base CoverMAINTENANCE REPLACING THE FANMAINTENANCE VALVE ASSEMBLY REPLACEMENTON/OFF Wires BurnerMAINTENANCE 11Slightly lift out valve tray12 Disconnect the inlet gas line U32S-5FPI Direct Vent Gas InsertMAIN ASSEMBLY PARTS LISTDescription PARTS LIST BURNER ASSEMBLYDescription 4 10 11 9 13PARTS LIST 1425-512Door Bottom Assembly 2425-513Frame InsideFACEPLATE AND DOORFRAME 3425-514Faceplate Outside 4425-942Hearth TrimU32S-5FPI Direct Vent Gas Insert U32S-5FPI Direct Vent Gas Insert WARRANTY The Warranty Limited LifetimeConditions ExclusionsSee the inside back cover for details