Regency U32S-LP5 Installation, Important Message Save These Instructions, For Your Safety

Page 7
INSTALLATION

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The FPI Gas Insert must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.

NOTE: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

FOR YOUR SAFETY

Thisappliancerequiresairforpropercombustion. Always provide adequate combustion and ventilation air. Follow instructions and information in CAN/CGA B149 (in Canada) or the National Fuel Gas CodeANSI Z223.1 (in the USA), regarding requirements for combustion and ventilation air.

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit must be disconnected.

Gas Input Capacity:

 

Natural Gas

24,500

Btu/h

Propane

20,500

Btu/h

Min. Input

 

 

Natural Gas

16,500

Btu/h

Propane

17,000

Btu/h

Fuels: Approved for use with both natural gas, and propane. Approved as is for use at 0' to 4,500' (0-1370m).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 110 CFM.

Vent System: 3" co-linear aluminum flex.

The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independent of any installed system.

GAS PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than

1/2 psig. (3.45 kPa).

INSTALLATION INTO A SOLID FUEL BURNING FIREPLACE OR FACTORY BUILT FIREPLACE

The U32S Gas Insert has been tested and approved to be vented into any masonry fireplace or approved solid fuel burning factory built fireplace that will allow the insert to physically fit into the firebox. Refer to "Minimum Fireplace Dimensions" section for minimum fireplace clearances.

If the factory built fireplace* height is too low for your Insert, you may remove the smoke baffle plate, damper, refractory (firebricks), glass doors, screen rails, screen mesh and log grates from the factory built fireplace as long as these items are saved and are reinstalled in the event that the Insert is removed.

Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. If any part is removed it must not weaken the structural integrity of the factory built fireplace.

NOTE: Any alterations made to the listed solid fuel burning factory built fireplace may void the listing of the fireplace.

*Check with your local inspector before commencing with this installation.

Installer must mechanically attach the supplied label to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.

"WARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction."

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

General Safety Information

1)The appliance installation must conform with local codes or in the absence of local codes, with CAN/CGA B149 (in Canada) or the National Fuel Gas Code ANSI Z223.1 in the U.S.A.This appliance should be installed by a qualified gas fitter technician only.

2)Installation and repair should be done by a qualified service person.

3)The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, animal hair, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

4)See general construction and assembly instructions. This appliance may only be installed in a vented, noncombustible fireplace.

5)This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6)Always connect this insert to a vent system venting to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is properly sized and is of adequate height to provide the proper draft.

7)Inspect the venting system annually for blockage and any signs of deterioration.

8)Any glass removed for servicing must be replaced prior to operating the appliance.

9)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

10)Due to high temperatures, the appliance should be located out of high traffic areas and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures, especially the fireplace glass and gold trims, and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable material should not be placed on or near the appliance.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

U32S-5 FPI Direct Vent Gas Insert

7

Image 7
Contents 918-788 Installation ManualU32 Sunrise Gas Insert OwnersTO THE NEW OWNER PARTS LIST TABLE OF CONTENTSSAFETY LABEL MAINTENANCESAFETY LABEL 5.08 Modifications to NFPA-54,Chapter REQUIREMENTSMA Code - CO Detector for the State of Massachusetts onlyU32S-5FPI Direct Vent Gas Insert UNIT DIMENSIONSGAS PRESSURE TESTING INSTALLATIONFOR YOUR SAFETY SPECIFICATIONSMANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS INSTALLATIONINSTALLATION CHECKLIST MINIMUM FIREPLACE DIMENSIONSCOMBUSTIBLE MANTEL INSTALLATIONGAS CONNECTION VENTINGGAS INSERT AERATION SYSTEM INSTALLATIONFLUE LINER INSTALLATION GAS PIPE PRESSURE TESTINGIF IN DOUBT DO NOT DO THIS CONVERSION INSTALLATIONU32S-5using SIT 820 NOVA Gas Valve CONVERSION KIT # 434-969FROM NG TO LPthe wrench by the short side INSTALLATIONInstaller Notice Do not overtighten the screw. Recommended to gripGround wire from kit INSTALLATIONInstallation of the DC Sparker Ignitor Wire Piezo Ignitorremote control the 120V wires INSTALLATIONOPTIONAL REMOTE CONTROL to the 120V wires Thermostat Wire Tableto disconnection when servicing INSTALLATIONWIRING DIAGRAMS CAUTION Label all wires priorINSTALLATION Minimum Air shutter Opening INSTALLATIONINSTALLATION ON BURNER GLASS CRYSTAL OR OPTIONAL CERAMIC STONESDiagram Diagram 1a Diagram 1b Diagram INSTALLATIONSTANDARD FLUSH DOOR Door Frame INSTALLATIONFACEPLATE AND DOOR FRAME INSTALLATION Kit# 425-914Contents List10Slide unit into final position INSTALLATIONCompleted Faceplate & Door Frame Installation 8Lower the door frame gently into place4 Hearth Trim Installation INSTALLATIONOPTIONAL HEARTH TRIM INSTALLATION 2 Hearth Trim InstallationOPERATING INSTRUCTIONS OPERATING INSTRUCTIONSLIGHTING PROCEDURE SHUTDOWN PROCEDUREDO NOT REMOVE THIS INSTRUCTION PLATE MAINTENANCE INSTRUCTIONSOPERATING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLATEGLASS GASKET MAINTENANCEGENERAL VENT MAINTENANCE DOOR GLASSBurner MAINTENANCEFAN MAINTENANCE FAN REMOVALBase Cover MAINTENANCEFan access plate Pilot assembly wiresREPLACING THE FAN MAINTENANCEBurner MAINTENANCEVALVE ASSEMBLY REPLACEMENT ON/OFF WiresU32S-5FPI Direct Vent Gas Insert MAINTENANCE11Slightly lift out valve tray 12 Disconnect the inlet gas lineMAIN ASSEMBLY PARTS LISTDescription 4 10 11 9 13 PARTS LISTBURNER ASSEMBLY Description3425-514Faceplate Outside 4425-942Hearth Trim PARTS LIST1425-512Door Bottom Assembly 2425-513Frame Inside FACEPLATE AND DOORFRAMEU32S-5FPI Direct Vent Gas Insert U32S-5FPI Direct Vent Gas Insert Exclusions WARRANTYThe Warranty Limited Lifetime ConditionsSee the inside back cover for details