Regency U32S-LP5 Table Of Contents, Safety Label, Maintenance, Parts List, Warranty, Requirements

Page 3
Image 3
Contents 918-788 Installation ManualU32 Sunrise Gas Insert OwnersTO THE NEW OWNER PARTS LIST TABLE OF CONTENTSSAFETY LABEL MAINTENANCESAFETY LABEL 5.08 Modifications to NFPA-54,Chapter REQUIREMENTSMA Code - CO Detector for the State of Massachusetts onlyU32S-5FPI Direct Vent Gas Insert UNIT DIMENSIONSGAS PRESSURE TESTING INSTALLATIONFOR YOUR SAFETY SPECIFICATIONSMANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS INSTALLATIONINSTALLATION CHECKLIST MINIMUM FIREPLACE DIMENSIONSCOMBUSTIBLE MANTEL INSTALLATIONGAS CONNECTION VENTINGGAS INSERT AERATION SYSTEM INSTALLATIONFLUE LINER INSTALLATION GAS PIPE PRESSURE TESTINGIF IN DOUBT DO NOT DO THIS CONVERSION INSTALLATIONU32S-5using SIT 820 NOVA Gas Valve CONVERSION KIT # 434-969FROM NG TO LPthe wrench by the short side INSTALLATIONInstaller Notice Do not overtighten the screw. Recommended to gripGround wire from kit INSTALLATIONInstallation of the DC Sparker Ignitor Wire Piezo Ignitorremote control the 120V wires INSTALLATIONOPTIONAL REMOTE CONTROL to the 120V wires Thermostat Wire Tableto disconnection when servicing INSTALLATIONWIRING DIAGRAMS CAUTION Label all wires priorINSTALLATION Minimum Air shutter Opening INSTALLATIONINSTALLATION ON BURNER GLASS CRYSTAL OR OPTIONAL CERAMIC STONESINSTALLATION Diagram Diagram 1a Diagram 1b DiagramSTANDARD FLUSH DOOR Door Frame INSTALLATIONFACEPLATE AND DOOR FRAME INSTALLATION Kit# 425-914Contents List10Slide unit into final position INSTALLATIONCompleted Faceplate & Door Frame Installation 8Lower the door frame gently into place4 Hearth Trim Installation INSTALLATIONOPTIONAL HEARTH TRIM INSTALLATION 2 Hearth Trim InstallationOPERATING INSTRUCTIONS OPERATING INSTRUCTIONSLIGHTING PROCEDURE SHUTDOWN PROCEDUREDO NOT REMOVE THIS INSTRUCTION PLATE MAINTENANCE INSTRUCTIONSOPERATING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLATEGLASS GASKET MAINTENANCEGENERAL VENT MAINTENANCE DOOR GLASSBurner MAINTENANCEFAN MAINTENANCE FAN REMOVALBase Cover MAINTENANCEFan access plate Pilot assembly wiresREPLACING THE FAN MAINTENANCEBurner MAINTENANCEVALVE ASSEMBLY REPLACEMENT ON/OFF WiresU32S-5FPI Direct Vent Gas Insert MAINTENANCE11Slightly lift out valve tray 12 Disconnect the inlet gas linePARTS LIST MAIN ASSEMBLYDescription 4 10 11 9 13 PARTS LISTBURNER ASSEMBLY Description3425-514Faceplate Outside 4425-942Hearth Trim PARTS LIST1425-512Door Bottom Assembly 2425-513Frame Inside FACEPLATE AND DOORFRAMEU32S-5FPI Direct Vent Gas Insert U32S-5FPI Direct Vent Gas Insert Exclusions WARRANTYThe Warranty Limited Lifetime ConditionsSee the inside back cover for details