Regency P33R-LP2, P33R-NG2 Installation Procedures, For Regency Direct Vent System Flex

Page 12

INSTALLATION

INSTALLATION PROCEDURES

for Regency Direct Vent System (Flex)

1)Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left. Locate the centerline of the termination and mark wall according- ly. Cut a 10"(254mm) hole in the wall (inside dimension).

Note: To make the installation more aes- thetically pleasing, we recom- mend framing out a square to mount the terminal to.

Note: A 1-1/2"(38mm) clearance around the liner must be maintained ex- cept that only a 1" (25mm) clear- ance is needed at the termination

*If this is an outside corner, the minimum distance between the vent and the outside corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Dura-Vent termination cap. See "F" on the diagram on page 9.

Minimum and Maximum Vent Clearances

end. We recommend framing a 10"(254mm) x 10"(254mm) (inside dimensions) hole to give structur- al rigidity for mounting the termi- nation.

Note: If installing termination on a siding covered wall, furring strips must be used to ensure that the termi- nation is not recessed into the siding.

2)

Level the fireplace and fasten it to the

 

framing using nails or screws through the

 

nailing strips.

3)

Assemble the vent assembly by applying

5)Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.

6)Pull the centre 4"(100mm) liner and outer 6- 7/8"(175mm) liner out enough to slip over the flue collars of the fireplace.

7)Apply Mill Pac over the fireplace inner collar and slip the 4"(100mm) liner down over it and attach with 3 supplied screws.

9)Apply a bead of silicone between the thim- ble and termination and around the outer edge of the terminal at the wall in order to keep the water out.

IMPORTANT: Do not locate termina- tion hood where excessive snow or ice buildup may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting sys- tem. When using snow blowers, make sure snow is not directed to- wards vent termination area.

Mill Pac to the 4"(100mm) inner collar of the

termination and slipping the 4"(100mm) liner

over it at least 1-3/8" (35mm). Fasten with

the 3 screws (drilling pilot holes will make

this easier). Apply Mill Pac or high temper-

ature silicone to the 6-7/8"(175mm) flex

pipe and slip it over the 6-7/8" outer collar

of the vent terminal at least 1-3/8"(35mm)

and fasten with the 3 screws.

4) Separate the 2 halves of the wall thimble

and securely fasten the one with the tabs

to the outside wall making sure that the tabs

are on top and bottom. Fasten the other

thimble half to the inside wall. The thimble

halves slip inside each other and can be

adjusted for 2 x 4 or 2 x 6 walls. The liners

must slip over the collars a minimum

of 1-3/8".

8)Do the same with the 6-7/8"(175mm) liner.

12

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

Image 12
Contents P33R Zero Clearance Rear Direct Vent Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Installation General Safety InformationSave These Instructions Before YOU StartUnit Dimensions ChecklistLocating Your GAS Stove Duct System OptionClearances Combustible Mantels Mantel LEG ClearancesFire hazard is an extreme risk if These clearances are not adFraming and Finishing Unit Assembly Prior to Installation Top Standoff AssemblyTop Facing Support Side Nailing Strips Screw PositionVent Air supply outletVenting Introduction Regency Direct Vent System Flex Horizontal Terminations onlyInstallation Procedures For Regency Direct Vent System FlexSimpson DURA-VENT Venting Simpson DURA-VENT Venting Components ListSimpson Dura-Vent Direct Vent GS Parts not supplied by Dura-VentVenting Arrangements Horizontal Terminations Dura-Vent System or Regency DV FlexVenting Arrangements Vertical Terminations Propane & Natural GasVertical Termination With CO-LINEAR Flex System Required PartsAlternate Approved Caps Installation Horizontal Installations Snorkel TerminationsGAS Line Installation Vertical TerminationPilot Adjustment GAS Pipe Pressure TestingHigh Elevation T. Valve DescriptionConversion Kit Contains Rear Log SupportLOG SET Installation Optional Brick PanelsStandard Flush Door Optional Flush TrimFlush Louvers Double Screen DoorOptional BAY Door Optional Wall Thermostat Remote Control Optional Wall SwitchThermostat Wire Table BAY LouversWiring Diagram Do not cut the ground terminal off under any circumstancesInstalling the Optional FAN Secure left side with 2 screwsOperating Instructions Copy of the Lighting Plate InstructionsLighting Procedure Shutdown ProcedureAeration Adjustment Operating InstructionsMaintenance Flush Glass Replacement Bay Glass Replacement ThermopileThermocouple Glass GasketInstalling Valve Removing ValveShut off the gas supply Parts List DescriptionBurner & Log Assembly Flush Front & Louvers Bay Front & Louvers Page Page Warranty Warranty LifetimeInstaller Please complete the following information