MAINTENANCE

THERMOPILE/

Flush Glass Replacement

Bay Glass Replacement

THERMOCOUPLE

1)Open the bottom louvers.

2)Loosen the thermocouple or thermopile with a 7/16" wrench.

3)Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Discon- nect thermopile by loosening 2 screws marked TP on the valve.

4)Drop the thermocouple or thermopile down from the bracket and pull it out of the unit.

5)Reinstall the new ones in reverse order.

GLASS GASKET

If the glass gasket requires replacement use 5/8" flat glass gasket for the Bay Front (Part # 936-243) and a tadpole glass gasket for the Flush Front (Part # 936-155).

DOOR GLASS

Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized deal- ers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only, and follow our step-by- step instructions for replacement.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Re- placement of the glass panels should be done by a licensed or qualified service person.

Caution: Wear gloves when remov- ing damaged or broken glass.

Remove the flush door front (as per instructions on page 23). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame. The glass must have gasketing around it.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Remove the nuts holding the glass clips in place and remove.

3)Replace the glass. The glass must have gasketing around it.

5)Reverse the previous steps, replace the glass clips and fasten with the nuts but do not over tighten, as this can break the glass.

6)Replace door on the stove and check the seal.

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

31

Image 31
Contents P33R Zero Clearance Rear Direct Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Before YOU Start InstallationGeneral Safety Information Save These InstructionsDuct System Option Unit DimensionsChecklist Locating Your GAS StoveThese clearances are not ad Clearances Combustible MantelsMantel LEG Clearances Fire hazard is an extreme risk ifFraming and Finishing Screw Position Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsAir supply outlet VentRegency Direct Vent System Flex Horizontal Terminations only Venting IntroductionFor Regency Direct Vent System Flex Installation ProceduresParts not supplied by Dura-Vent Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Simpson Dura-Vent Direct Vent GSDura-Vent System or Regency DV Flex Venting Arrangements Horizontal TerminationsPropane & Natural Gas Venting Arrangements Vertical TerminationsRequired Parts Vertical Termination With CO-LINEAR Flex SystemAlternate Approved Caps Installation Snorkel Terminations Horizontal InstallationsVertical Termination GAS Line InstallationT. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationRear Log Support Conversion Kit ContainsOptional Brick Panels LOG SET InstallationOptional Flush Trim Standard Flush DoorDouble Screen Door Flush LouversOptional BAY Door BAY Louvers Optional Wall Thermostat Remote ControlOptional Wall Switch Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramSecure left side with 2 screws Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsOperating Instructions Lighting ProcedureShutdown Procedure Aeration AdjustmentMaintenance Glass Gasket Flush Glass Replacement Bay Glass ReplacementThermopile ThermocoupleRemoving Valve Installing ValveShut off the gas supply Description Parts ListBurner & Log Assembly Flush Front & Louvers Bay Front & Louvers Page Page Warranty Lifetime WarrantyInstaller Please complete the following information