MAINTENANCE
THERMOPILE/
Flush Glass Replacement | Bay Glass Replacement |
THERMOCOUPLE
1)Open the bottom louvers.
2)Loosen the thermocouple or thermopile with a 7/16" wrench.
3)Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Discon- nect thermopile by loosening 2 screws marked TP on the valve.
4)Drop the thermocouple or thermopile down from the bracket and pull it out of the unit.
5)Reinstall the new ones in reverse order.
GLASS GASKET
If the glass gasket requires replacement use 5/8" flat glass gasket for the Bay Front (Part #
DOOR GLASS
Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized deal- ers. Do not use abrasive materials. Do not clean the glass when hot.
In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only, and follow our
WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Re- placement of the glass panels should be done by a licensed or qualified service person.
Caution: Wear gloves when remov- ing damaged or broken glass.
Remove the flush door front (as per instructions on page 23). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame. The glass must have gasketing around it.
1)Remove the door from the unit and place on a soft surface to prevent scratching.
2)Remove the nuts holding the glass clips in place and remove.
3)Replace the glass. The glass must have gasketing around it.
5)Reverse the previous steps, replace the glass clips and fasten with the nuts but do not over tighten, as this can break the glass.
6)Replace door on the stove and check the seal.