Regency P33R-NG2, P33R-LP2 installation manual Conversion Kit Contains, Rear Log Support

Page 21

INSTALLATION

Conversion Kit from Natural Gas to Propane Model #431-969

for P33R-2 using SIT 820 NOVA Gas Valve

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit Contains:

Qty. Part #

Description

1910-018 SIT Conversion Kit-50% Turndown LP

1

910-037

LP Injector (Pilot Orifice)

1

904-163

Burner Orifice #54

1

908-255

Decal "Converted to Propane"

1

908-528

Red "PROPANE" label

1908-529 5/32" Allen Key

1908-812 Instruction Sheet

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it is installed).

3)Open the flush door and remove the door.

4)Remove the logs, embers, and brick panels (if used).

5)Remove the 2 screws holding the Burner Assembly to the firebox base. Push the Burner Assembly to the left and lift out.

Remove the 2 screws, push Burner Assem-

bly to the left and lift out.

6)Remove the 2 Air Deflectors (2 screws per deflector) attached to the Rear Log Sup- port. Discard the Air Deflectors, they are only required when burning Natural Gas.

Rear Log Support

Air Deflector

screws

Air Deflector

7)Pull off the pilot cap to expose the pilot orifice.

8)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap.

9)Remove burner orifice with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind the orifice.

Burner Orifice

10)Reinstall new burner orifice LP stamped #54 and tighten.

11)Remove and discard the 3 pressure regu- lator mounting screws (A), pressure reg- ulator tower (B) and diaphragm (C).

12)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.

13)Reverse steps 5) to 2).

14)Attach clear label "This unit has been converted to Propane" near or on the serial

# decal. Attach white label "This valve has been converted from NG to LPG using SIT conversion Kit Code 0.907.202" onto the valve.

15)Replace yellow "Natural Gas" label with red "Propane" label

16)Check for gas leaks.

17)Check inlet and outlet pressures.

18)Check operation of flame control.

19)Check for proper flame appearance and glow on logs.

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

21

Image 21
Contents P33R Zero Clearance Rear Direct Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label General Safety Information InstallationSave These Instructions Before YOU StartChecklist Unit DimensionsLocating Your GAS Stove Duct System OptionMantel LEG Clearances Clearances Combustible MantelsFire hazard is an extreme risk if These clearances are not adFraming and Finishing Top Standoff Assembly Unit Assembly Prior to InstallationTop Facing Support Side Nailing Strips Screw PositionAir supply outlet VentRegency Direct Vent System Flex Horizontal Terminations only Venting IntroductionFor Regency Direct Vent System Flex Installation ProceduresSimpson DURA-VENT Venting Components List Simpson DURA-VENT VentingSimpson Dura-Vent Direct Vent GS Parts not supplied by Dura-VentDura-Vent System or Regency DV Flex Venting Arrangements Horizontal TerminationsPropane & Natural Gas Venting Arrangements Vertical TerminationsVertical Termination With CO-LINEAR Flex System Required PartsAlternate Approved Caps Installation Snorkel Terminations Horizontal InstallationsVertical Termination GAS Line InstallationGAS Pipe Pressure Testing Pilot AdjustmentHigh Elevation T. Valve DescriptionRear Log Support Conversion Kit ContainsOptional Brick Panels LOG SET InstallationOptional Flush Trim Standard Flush DoorFlush Louvers Double Screen DoorOptional BAY Door Optional Wall Switch Optional Wall Thermostat Remote ControlThermostat Wire Table BAY LouversDo not cut the ground terminal off under any circumstances Wiring DiagramSecure left side with 2 screws Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsShutdown Procedure Lighting ProcedureAeration Adjustment Operating InstructionsMaintenance Thermopile Flush Glass Replacement Bay Glass ReplacementThermocouple Glass GasketInstalling Valve Removing ValveShut off the gas supply Description Parts ListBurner & Log Assembly Flush Front & Louvers Bay Front & Louvers Page Page Warranty Lifetime WarrantyInstaller Please complete the following information