Regency P33R-LP2, P33R-NG2 installation manual Flush Louvers, Double Screen Door, Optional BAY Door

Page 24

INSTALLATION

FLUSH LOUVERS

1)Install the top louver by sliding the two bracket clips into the brackets located un- derneath the top of the firebox.

2)Install the bottom louver by folding the lou- ver down and then sliding the Bottom Lou- ver bracket down onto the 2 pins on the base of the unit (dia. 1). Secure with 1 screw as per dia. 2.

Diagram 1

Diagram 2

DOUBLE SCREEN

DOOR

1)Pull out the top louver.

2)Center the screen door and hook over the flush door.

Note: Top and bottom louvers are different.

3)Open the bottom louver. Pull the Burner ON/ OFF control box from inside the bottom of the fireplace and position the slots in the bracket over the 2 screws on the left side of the bottom louver. Push down to lock into place. Tighten the screws.

3)Open the screen door(s) and secure the screen door to the flush door front with 2 clips on the bottom left and right side.

Clip locations

Clip installed on right side.

OPTIONAL BAY DOOR

The Bay louvers MUST be used

with the Bay glass option.

Note: If any maintenance etc. must be done in the firebox, first remove the Bay louvers and door.

Optional Bay Trim

Attach 4 supplied magnets each to the back of the top and bottom trim pieces, and attach trim to the top and bottom of Bay door.

Screws on

Burner ON/OFF

louver bracket

control box

Burner ON/OFF control box attached to

bottom flush louver.

The optional Bay door is an overlay on the flush front. The standard flush door and glass must remain on the unit.

1)Hook the top of the bay door over the flush door flange and swing the bottom against the bottom flange of the flush door.

2)Secure to the flush door bottom bracket with 2 screws provided.

3)Slide the valve extension knobs onto the valve knobs.

24

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

Image 24
Contents P33R Zero Clearance Rear Direct Vent Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Installation General Safety InformationSave These Instructions Before YOU StartUnit Dimensions ChecklistLocating Your GAS Stove Duct System OptionClearances Combustible Mantels Mantel LEG ClearancesFire hazard is an extreme risk if These clearances are not adFraming and Finishing Unit Assembly Prior to Installation Top Standoff AssemblyTop Facing Support Side Nailing Strips Screw PositionVent Air supply outletVenting Introduction Regency Direct Vent System Flex Horizontal Terminations onlyInstallation Procedures For Regency Direct Vent System FlexSimpson DURA-VENT Venting Simpson DURA-VENT Venting Components ListSimpson Dura-Vent Direct Vent GS Parts not supplied by Dura-VentVenting Arrangements Horizontal Terminations Dura-Vent System or Regency DV FlexVenting Arrangements Vertical Terminations Propane & Natural GasVertical Termination With CO-LINEAR Flex System Required PartsAlternate Approved Caps Installation Horizontal Installations Snorkel TerminationsGAS Line Installation Vertical TerminationPilot Adjustment GAS Pipe Pressure TestingHigh Elevation T. Valve DescriptionConversion Kit Contains Rear Log SupportLOG SET Installation Optional Brick PanelsStandard Flush Door Optional Flush TrimFlush Louvers Double Screen DoorOptional BAY Door Optional Wall Thermostat Remote Control Optional Wall SwitchThermostat Wire Table BAY LouversWiring Diagram Do not cut the ground terminal off under any circumstancesInstalling the Optional FAN Secure left side with 2 screwsOperating Instructions Copy of the Lighting Plate InstructionsLighting Procedure Shutdown ProcedureAeration Adjustment Operating InstructionsMaintenance Flush Glass Replacement Bay Glass Replacement ThermopileThermocouple Glass GasketInstalling Valve Removing ValveShut off the gas supply Parts List DescriptionBurner & Log Assembly Flush Front & Louvers Bay Front & Louvers Page Page Warranty Warranty LifetimeInstaller Please complete the following information