Regency P33R-NG2, P33R-LP2 installation manual Standard Flush Door, Optional Flush Trim

Page 23

INSTALLATION

A) 02-57

 

 

60

 

02

-

C)

B) 02-61

 

 

 

6) Place the bottom left front edge of Log D) 02-58 against the left edge of the burner tray and rest the log on the cutout on Log C) 02-60.

A) 02-57

D) 02-58

C)102

-60

B) 02-61

 

 

Cutout

8) Place the embers on the front of the burner tray in the places shown on the photo.

Place embers in these 3 locations

on the burner tray.

9) Test fire to ensure proper light off (make

 

sure flame flows smoothly from one end of

Diagram 1

burner to the other). If there is any flame

 

hesitation, check that area for any block-

 

age of the burner ports.

 

10) Install flush glass and bay glass (if used) as per instructions in this manual.

A) 02-57

 

 

 

 

 

 

 

Diagram 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D) 02-58

 

 

 

 

 

 

Use the hook to pull the spring out until you can

 

 

60

 

E)

 

 

 

 

 

02

 

put the hook into the slot on the bottom door

 

02

-

 

 

 

 

 

 

 

bracket. Repeat for 2nd spring. See diagram 3.

 

 

 

 

-

C)

 

 

B) 02-61

 

 

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7)Position Log E) 02-59 across the cutouts in Logs B) 02-61 and C) 02-60. The notch in the bottom right end fitting against the 5th grate tab.

 

 

 

 

E)

 

 

 

 

02

 

 

 

 

-

 

 

 

 

59

 

02

-

60

B) 02-61

 

 

 

C)

 

 

 

 

 

 

 

5th Grate Tab

A) 02-57

D) 02-58

 

 

60

E)

 

 

02

-

 

 

B) 02-61

02

 

C)

 

-

 

 

 

59

 

 

 

 

STANDARD FLUSH

DOOR

The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

Diagram 3

To remove the flush door, reverse the above steps.

Optional Flush Trim

Attach the round magnets to the back of the top trim piece and to the bottom trim piece, then attach trim to the top and bottom of Flush door.

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

23

Image 23
Contents P33R Zero Clearance Rear Direct Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Before YOU Start InstallationGeneral Safety Information Save These InstructionsDuct System Option Unit DimensionsChecklist Locating Your GAS StoveThese clearances are not ad Clearances Combustible MantelsMantel LEG Clearances Fire hazard is an extreme risk ifFraming and Finishing Screw Position Unit Assembly Prior to InstallationTop Standoff Assembly Top Facing Support Side Nailing StripsAir supply outlet VentRegency Direct Vent System Flex Horizontal Terminations only Venting IntroductionFor Regency Direct Vent System Flex Installation ProceduresParts not supplied by Dura-Vent Simpson DURA-VENT VentingSimpson DURA-VENT Venting Components List Simpson Dura-Vent Direct Vent GSDura-Vent System or Regency DV Flex Venting Arrangements Horizontal TerminationsPropane & Natural Gas Venting Arrangements Vertical TerminationsAlternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts Installation Snorkel Terminations Horizontal InstallationsVertical Termination GAS Line InstallationT. Valve Description Pilot AdjustmentGAS Pipe Pressure Testing High ElevationRear Log Support Conversion Kit ContainsOptional Brick Panels LOG SET InstallationOptional Flush Trim Standard Flush DoorOptional BAY Door Flush LouversDouble Screen Door BAY Louvers Optional Wall Thermostat Remote ControlOptional Wall Switch Thermostat Wire TableDo not cut the ground terminal off under any circumstances Wiring DiagramSecure left side with 2 screws Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsOperating Instructions Lighting ProcedureShutdown Procedure Aeration AdjustmentMaintenance Glass Gasket Flush Glass Replacement Bay Glass ReplacementThermopile ThermocoupleShut off the gas supply Installing ValveRemoving Valve Description Parts ListBurner & Log Assembly Flush Front & Louvers Bay Front & Louvers Page Page Warranty Lifetime WarrantyInstaller Please complete the following information