Regency P33R-NG2 Simpson DURA-VENT Venting Components List, Simpson Dura-Vent Direct Vent GS

Page 13

INSTALLATION

SIMPSON DURA-VENT VENTING

Horizontal or Vertical Terminations

The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the P33R-2.

The minimum components required for a basic horizon- tal termination are:

1AstroCap Horizontal Termination Cap

190o Elbow

1Flue Adaptor

1Wall Thimble

1Length of pipe to suit wall thickness (see chart)

For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

The Regency AstroCapTM is certified for installations using FPI venting systems as well as Simpson Dura-Vent® and Direct Vent GS.

RegencyTM, and Regency AstroCapTM are the proprietary trade- marks of FPI Fireplace Products International Ltd.

Dura-Vent® and Direct Vent GS are registered and/or proprie- tary trademarks of Simpson Dura-Vent Co. Inc.

Simpson Dura-Vent

Direct Vent GS

SIMPSON DURA-VENT VENTING COMPONENTS LIST

All Simpson Dura-Vent components are available directly from Regency.

Part # Description

971Horiz. Termination Kit includes: 90o black elbow, wall thimble cover, horiz. square termination cap, 24" black pipe, 11" -14" 5/8" adjustable black pipe

970Basic Horiz. Termination. Kit includes: 90o black elbow, wall thimble cover, horiz. square termination cap

978Vert. Termination Kit includes 0/12 - 6/12 pitch adjustable flashing, storm collar, low profile term. cap

908B 6" Pipe Length - Black

907B 9" Pipe Length - Black

90612" Pipe Length - Galv.

906B 12" Pipe Length - Black

90424" Pipe Length - Galv.

904B 24" Pipe Length - Black

90336" Pipe Length - Galv.

903B 36" Pipe Length - Black

Part #

Description

Part #

Description

902

48" Pipe Length - Galv.

982

Snorkel - 14" Rise Termination Cap

902B

48" Pipe Length - Black

981

Snorkel - 36" Rise Termination Cap

911B 11"-14 5/8" Adjustable Pipe Length -

 

 

 

Black

940

Wall Thimble - Support/Box

917B

17"- 24" Adjustable Length - Black

941

Cathedral/Ceiling - Support/Box

 

 

3951

Brass Trim for Wall Thimble/Ceiling

945

45O Elbow - Galv.

 

Support

945B

45O Elbow - Black

963

Firestop Spacer

945G

45O Elbow - Swivel - Galv.

943

Flashing 0/12-6/12

945BG

45O Elbow - Swivel - Black

943S

Flashing 7/12-12/12

990

90O Elbow - Galv.

953

Storm Collar

990B

90O Elbow - Black

950

Vinyl Siding Standoff

990G

90O Elbow - Swivel - Galv.

988

Wall Strap

990BG

90O Elbow - Swivel - Black

942

Wall Thimble

991

High Wind Termination Cap (Vertical)

Parts not supplied by Dura-Vent

980

Vertical Termination Cap

946-506/P Vent Guard (Optional)

984

Horizontal Square Termination Cap

640-530/P Riser Vent

985

Horizontal Square High Wind

510-994

Flue Adapter

 

Termination Cap

946-205 Vinyl Siding Shield for Riser

 

 

 

Vent Terminal

 

 

946-523/P AstroCap Termination Cap

Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace

13

Image 13
Contents P33R Zero Clearance Rear Direct Vent To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label General Safety Information InstallationSave These Instructions Before YOU StartChecklist Unit DimensionsLocating Your GAS Stove Duct System OptionMantel LEG Clearances Clearances Combustible MantelsFire hazard is an extreme risk if These clearances are not adFraming and Finishing Top Standoff Assembly Unit Assembly Prior to InstallationTop Facing Support Side Nailing Strips Screw PositionAir supply outlet VentRegency Direct Vent System Flex Horizontal Terminations only Venting IntroductionFor Regency Direct Vent System Flex Installation ProceduresSimpson DURA-VENT Venting Components List Simpson DURA-VENT VentingSimpson Dura-Vent Direct Vent GS Parts not supplied by Dura-VentDura-Vent System or Regency DV Flex Venting Arrangements Horizontal TerminationsPropane & Natural Gas Venting Arrangements Vertical TerminationsRequired Parts Vertical Termination With CO-LINEAR Flex SystemAlternate Approved Caps Installation Snorkel Terminations Horizontal InstallationsVertical Termination GAS Line InstallationGAS Pipe Pressure Testing Pilot AdjustmentHigh Elevation T. Valve DescriptionRear Log Support Conversion Kit ContainsOptional Brick Panels LOG SET InstallationOptional Flush Trim Standard Flush DoorDouble Screen Door Flush LouversOptional BAY Door Optional Wall Switch Optional Wall Thermostat Remote ControlThermostat Wire Table BAY LouversDo not cut the ground terminal off under any circumstances Wiring DiagramSecure left side with 2 screws Installing the Optional FANCopy of the Lighting Plate Instructions Operating InstructionsShutdown Procedure Lighting ProcedureAeration Adjustment Operating InstructionsMaintenance Thermopile Flush Glass Replacement Bay Glass ReplacementThermocouple Glass GasketRemoving Valve Installing ValveShut off the gas supply Description Parts ListBurner & Log Assembly Flush Front & Louvers Bay Front & Louvers Page Page Warranty Lifetime WarrantyInstaller Please complete the following information