INSTALLATION
VENTING ARRANGEMENTS
HORIZONTAL TERMINATION (FLEX)
Regency® Direct Vent System
These venting systems, in combination with the L900E, have been tested and listed as a direct vent system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.
FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the L900E using a flexible vent.
INSTALLATION
FPI Kit # | Length | Contains: | |
6 Feet | 1) | 8” fl exible liner (Kit length) | |
|
| 2) | 5” fl exible liner (Kit length) |
|
| 3) | spring spacers (3) |
|
| 4) | thimble (2) |
|
| 5) | AstroCap termination cap (1) |
10 Feet | 6) | screws (12) | |
|
| 7) | tube of Mill Pac (1) |
|
| 8) | plated screws (8) |
|
| 9) | S.S. screws #8 x |
|
| 10) | vinyl siding standoff |
|
|
|
|
Vinyl Siding
Standoff
Wall Thimble
(Mandatory in all
Horizontal Terminations)
5” dia. flue pipe |
| |
8” dia. | spring spacer | |
Flue pipe | ||
|
Vent Guard - if required*
(Part
AstroCap XLTM
Termination Cap
(Part #946-623/P)
*A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.
Notes:
1)Liner sections should be continuous without any joints or seams.
2)Only Flex pipe purchased from FPI may be used for Flex installations.
3)Horizontal vent must be supported every 3 feet.
4)Awallthimbleismandatoryforallhorizontalterminations due to high temperatures.
Regency® L900E Direct Vent Gas Fireplace | 15 |