Regency L900E-NG installation manual Safety Label, Installation

Page 4

SAFETY LABEL

 

This is a copy of the label that accompanies

 

each L900E-NG and L900E-LP Direct Vent

INSTALLATION

Gas Fireplace. We have printed a copy of the

contents here for your review. The safety label

the correct one.

 

is located on the right hand side of the unit,

 

visible when the exterior right side brick panel

 

is removed.

 

NOTE: Regency® units are constantly being

 

improved. Check the label on the unit and if

 

there is a difference, the label on the unit is

 

 

COPY OF SAFETY DECAL

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE`

322

Serial No. / No de serie

Listed: VENTED GAS FIREPLACE

Tested to: ANSI Z21.88-2005/CSA 2.33-2005, CAN/CGA-2.17-M91, ANSI Z21.50-2003/CSA 2.22-2003, ANSI Z21.50A-2003/ CSA 2.22A-2003, ANSI Z21-50B-2003/CSA Z22b-2003 Certified for / Certifiée pour: CANADA AND U.S.A.

NATURAL GAS FIREPLACE: MODEL L900E-NG

Factory Equipped For Altitude 0-4500ft. (0-1372m)

L900ENG- Model/Modele:

Min. Supply Pressure

5“

WC

(1.25 kpa)

 

 

Low Setting Man. Pressure

1.6"

WC

(0.39 kpa)

 

Max. Manifold Pressure

3.5"

WC

(0.87 kpa)

 

Orifice Size (Front Burner)

#47

DMS

 

 

Orifice Size (Back Burner)

#30

DMS

 

 

Minimum Input

11,000

Btu/h

(3.22 kW)

 

Maximum Input

48,000

Btu/h

(14.06 kW)

 

PROPANE GAS FIREPLACE: MODEL L900E-LP

L900ELP- Model/Modele:

Factory Equipped For Altitude 0-4500ft. (0-1372m)

Min. Supply Pressure

12"

WC

(2.98 kpa)

 

 

Low Setting Man. Pressure

3.6"

WC

(0.9 kpa)

 

Max. Manifold Pressure

10"

WC

(2.49 kpa)

 

Orifice Size (Front Burner)

#56

DMS

 

 

Orifice Size (Back Burner)

#50

DMS

 

 

Minimum Input

9,500

Btu/h

(2.78 kW)

 

Maximum Input

46,500

Btu/h

(13.62 kW)

VENTED GAS FIREPLACE

This appliance must be installed in accordance with the manufacturer’s installation instructions and with local codes, if any; if none, follow the current ANSI Z223.1 in the USA or the current CAN 1-B149 in Canada.

This vented gas fireplace is not for use with air filters.

For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used (Kit #546-969).

Certified for use with Heat Wave (Kit #946-556) and Heat Release (Kit #946-570). For use with glass doors certified with the appliance only.

Electrical Supply: 120 V, 0.22 A, 60 Hz

NOT FOR USE WITH SOLID FUEL

Minimum Clearances to Combustibles from Fireplace

Side Walls

*A

16"

(406mm)

 

 

 

 

 

 

Ceiling

B

49"

(1245mm)

 

B

 

Min. Mantel Height

C

17-1/2" (445mm)

 

 

 

D

F

Max. Mantel Depth

**D

13”

(330mm)

 

 

 

 

 

Alcove Width

E

84"

(2134mm)

 

A

 

Alcove Depth

F

36"

(914mm)

C

I

 

 

 

 

 

 

 

Non-Combustible Hearth Extension

 

H

 

 

G E

 

Hearth Height

G

2"

(51mm)

 

 

 

 

 

Hearth Width

H

33-1/8”

(841mm)

 

 

 

*Alcove side wall must have a min. of 16” (406mm) clearance on one side.

**Mantel depth taken at 27-1/2” (699mm) from front facing.

FPI Fireplace Products International Ltd., Delta BC, CANADA

 

MADE IN CANADA / FABRIQUE AU CANADA

918-624

4

Regency® L900E Direct Vent Gas Fireplace

Image 4
Contents Libertytm L900E Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label InstallationRequirements MA Code CO DetectorUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsHeat Release KIT Hearth RequirementsManufactured Mobile Home Additional Requirements Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesFraming & Finishing Header On EdgeUnit Assembly Prior to InstallationVenting Introduction Vent Restrictor PositionExterior Vent Termination Requirements Horizontal Termination Flex Venting ArrangementsFPI Kit # Length Contains Rigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart 58DVA-16ABL676 & L900 Direct Vent Fireplace Vent Restrictor Setting Allowable Horizontal TerminationsHorizontal Venting with Two 2 90o Elbows Vertical Venting with Three 3 90o Elbows Allowable Vertical Terminations Unit Installation with Horizontal Termination Unit Installation With Vertical Termination DiagramMinimum Vent FeetUnit Installation Astrocap XLPilot Adjustment TestingAeration GAS Line Installation AdjustmentBACK-UP Battery Installation Heat ShieldBrick Panel Installation Handle with care. do not Force Into PositionExterior Brick Panel Installation LOG SET Installation 03-41 03-44 03-45 03-4203-43Embers on bottom brick panel Wiring Diagram Do not cut the ground terminal off under any circumstancesOperating Instructions Backup Battery Operation During Power OutageNormal Operating Sounds GAS Appliances For Your Safety Read Before Lighting Copy of Lighting Plate InstructionsMaintenance Control BOX Replacement BACK-UP Battery ReplacementMaintainence Do not Remove Valve Tray Replacement Latch ScrewRear Log Stand Parts List Main AssemblyBurner & LOG Assembly Description 910-937Warranty Warranty Limited LifetimeInstaller Please complete the following information