MAINTENANCE
MAINTENANCE
11)Remove the rear log stand by removing the 4 screws.
Rear Log Stand
12)Carefully remove the bottom brick panel.
Bottom Brick Panel
13)Disconnect the inlet gas line from the valve.
14)Disconnect the 2 connectors from the modulating coil.
15)Disconnect the molex connector from the valve.
Molex Connector
16)Remove the igniter wire and the thermocouple wire from the control box.
17)Release the two grey wire clips on the bottom of the fi replace to release the wires attached to the valve assembly.
18)Disconnect the black and red wires from the solenoid valve.
19)Remove the 16 screws that hold the valve tray to the fi rebox and slightly pull out the valve tray.
Valve Tray Slightly Removed
20)Ensure that all wiring is free and clear of any obstructions. Completely pull out the valve tray.
21)Replace the valve tray and reverse steps to
22)Turn on the gas supply and check for gas leaks.
23)
24)
25)
26)
27)
28)
29)Check the inlet and outlet pressures.
30)
31)Check operation of fl ame control.
32)Check for proper fl ame appearance.
33)
Modulating Coil | Valve Tray |
40 | Regency® L900E Direct Vent Gas Fireplace |