Wayne T50S10-4 warranty Description, Unpacking, Safety Guidelines, General Safety Information

Page 1

Operating Instructions and Parts Manual

T50S10-2, T50S10-4, T51S10-4, T75S10-2, T75S10-4, T100S10-2

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Deep Well

Submersible Pumps

Description

This submersible pump is designed to supply water at the required pressure with high efficiency and a long service life. To maximize pump life, care must be taken in its installation and usage.

Unpacking

After unpacking the submersible pump, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts.

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

danger indicates an imminently

hazardous situation which, if not avoided, WILL result in death or serious injury.

Warning indicates a potentially

hazardous situation which, if not avoided, COULD result in death or serious injury.

Caution indicates a potentially

hazardous situation which, if not avoided, MAY result in minor or moderate injury.

Notice indicates important

information, that if not followed, may cause damage to equipment.

NOTE: Information that requires special attention.

General Safety

Information

California Proposition 65

This product contains chemicals,

including lead, known to the State of California to cause birth defects and other reproductive harm. Wash hands after handling.

General Safety

1.Read the instruction manual included with the product carefully. Be thoroughly familiar with the controls and the proper use of the equipment.

2.Know the pump application, limitations and potential hazards.

do not use to pump flammable

or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in explosive atmospheres. Pump should only be used with liquids compatible with pump component materials. Failure to follow this warning can result in personal injury and/or property damage.

disconnect power and release all

pressure from the system before attempting to install, service, relocate or perform any maintenance. Lock the power disconnect in the open position. Tag the power disconnect to prevent unexpected application of power.

3.Personal Safety:

a.Wear safety glasses at all times when working with pumps.

b.Keep work area clean, uncluttered and properly lit.

c.Keep visitors at a safe distance from work area.

4.Do not pump chemicals or corrosive liquids. Pumping these liquids shortens the life of the pumps seals and moving parts and will void warranty.

5.When installing pump, prevent foreign matter from falling into well, contaminating the water and damaging internal mechanical components.

6.Always test the water from the well for purity before use. Check with local health department for test procedure.

7.Do not run the pump dry or damage will occur and will void warranty.

All wiring should be performed by a

licensed or certified electrician.

8.For maximum safety, the unit should be connected to a grounded circuit equipped with a ground fault circuit interrupter (GFCI) device.

9.Make sure the line voltage and frequency of electrical current supply agrees with the motor wiring.

10.Do not attempt repairs to the electric motor. All repairs to the motor must be completed at a licensed or certified electrical motor repair shop.

11.Avoid kinking electrical cord and protect electrical cord from sharp objects, hot surfaces,

oil and chemicals. Replace or repair damaged or worn cords immediately.

Risk of electric shock! Never

connect the green wire (or green and yellow wire) to a live terminal!

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

© 2011 Wayne/Scott Fetzer Company.

For parts, product & service information

340601-001 5/11

 

visit www.waynepumps.com

 

Image 1
Contents General Safety Information Safety GuidelinesDescription UnpackingPre-Installation General Safety Electrical System InformationWiring Connections Control box chart Wire Splicing InstallationPower Supply Wire Installation Pump InstallationStandard Tank Hookup Connecting to TANK/WATER SystemSymptoms Troubleshooting ChartPossible Causes Corrective ActionsDamage to pump Symptoms Possible Causes Corrective ActionsAttach Your Receipt Here Limited WarrantyDirectives de Sécurité DéballageGénéralités Sur La Sécurité Généralités SUR LA SécuritéGénéralités Sur La Sécurité Suite Pré-InstallationSystème électrique 11-Fr Tableau de la boîte de contrôleÉpissure DE FIL Installation DU FIL Dalimentation Électrique12-Fr Installation DE Pompe Installation SuiteDémarrage INITIAL/NOUVEAUX Puits 13-FrRaccordement À UN Réservoir Standard Raccordement À UN RÉSERVOIR/ UN Aqueduc14-Fr 15-Fr 16-Fr Tableau de dépannageSymptômes Causes PossiblesSymptômes Causes Possibles Mesures Correctives 17-FrFixer Votre Facture ICI Nº DU Modèle Nº DE Série Date D’INSTALLATION18-Fr Para Desempacar DescripciónMedidas de Seguridad Informaciones Generales de SeguridadSistema eléctrico Pre-InstalaciónConexiones DE Cableado 21-Sp Tabla 4 Cuadro de la caja de controlEmpalme DE Cables InstalaciónInstalación DEL Cable DE LA Fuente DE Energía 22-SpInstalación DE LA Bomba Instalación ContinúaEncendido INICIAL/POZOS Nuevos 23-SpConexión DE UN Tanque Estándar Conexión a UN Sistema DE AGUA/ Tanque24-Sp 25-Sp Notas26-Sp Tabla de Identificación de ProblemasSíntomas Causas PosiblesSíntomas Causas Posibles Medida Correctivas 27-Sp28-Sp Anexe SU Recibo Aqui