External Water Tank Feature:

This unit is equipped with a secondary “External Water Tank” which sits on a support tray and easily attaches to the rear side of the unit by means of a quick connect fitting. The male quick connect is attached to the water tank, the female quick connect is attached to the back of the main unit. We recommend the external water tank be connected to the main unit at all times during both air conditioning and dehumidifying modes. These water tanks allow for the storage of excess accumulated condensed water produced during cooling/dehumidifying operation.

It is possible to operate the unit utilizing the “Internal” (primary) water tank only. (However, running time/operation maybe reduced during high humidity conditions) If the external water tank is not connected to the main unit, (excess) condensed water is automatically directed into the internal water tank. When the external water tank is utilized, (excess) condensed water is directed first into the external tank. When the external tank is full the water will then backflow into the internal tank.

Cooling Operation:

During air conditioning mode condensed water accumulates in a pre-cooler drip tray located underneath the evaporator (cooling) coil. When the water level reaches a predetermined level, the water flow is directed into a small (well) holding tank located at the bottom of the unit. When the water level in the well reaches a pre-determined level, a water pump is automatically activated that pumps the water upto the condenser coil and is subsequently cascaded across the fins of the condenser coil.

This showering action is very efficient in terms of;

1)Keeping the condenser coil cool during operation.

2)Provides maximum cooling efficiency.

As the water cascades across the heated fins of the condenser coil, it is evaporated. This process minimizes accumulated water from being stored in both holding tanks, which results in longer running times and less frequent emptying of the water tanks. This process is continuous during air conditioning mode only. NOTE: During high humidity conditions, if the rate of water being condensed exceeds the rate of water being evaporated, a solenoid valve automatically opens allowing for excess water to be directed into the holding tanks.

When the water level in the well returns to normal, the solenoid valve automatically closes and the water is again directed into well and the water pump continues normal operation. When the water level inside the external tank reaches it’s maximum level, the water will then backflow into the (primary) internal water tank. The water level inside the internal tank (only) is monitored/controlled by a float switch mechanism (safety shut-off) self-activated when the water level reaches a predetermined level, causing the unit to stop/cease operation automatically and the tanks will have to be emptied. The fan motor will continue to operate. (this is normal)

NOTE: The float switch mechanism (safety shut- off) is activated/controlled by the water level inside the (primary) internal water tank only.

NOTE:

The quick connect fittings supplied with both the main unit and external water tank are "self sealing" connections.

This means as soon as the quick connects are "disconnected", water flow between the main unit and external water tank

stops immediately.

External Water Tank Instructions:

1.Attach the water tank support tray (with castors) to the saddle bracket located at the rear (lower section) of the unit, using the screws provided. See Fig. 35

Fig.35

5

Image 11
Contents Confort Hogareño Portátil de 3 Estaciones 800-26- RPortable 3 Season Home Comfort Appareil de confort au foyer portable 3 saisonsManuel ’UTILISATION Manual DEL Usuario Unit Parts Identification Table Of ContentsKeep these instructions for future reference This symbol denotes a caution or warningIntroduction Garantía Limitada Remoción y Limpieza del Filtro de Aire Cuidado y MantenimientoSuggested Individual Branch Circuit Electrical SpecificationsUnit Specifications Model DPAC9030 DPAC12030 Power ConsumptionElectric Shock Hazard Window InstallationEnergy-Saving Tips De operación programada Instrucciones de Operación del Control Remoto continuaciónSleep Modo Nocturno Nota La Período Operación Aumento de temperaturaVelocidad del Ventilador Instrucciones de Operación del Control RemotoVerifique lo siguiente Ajuste de Temperatura Presione los botonesExternal Water Tank Instructions External Water Tank FeatureExternal Water Tank Instructions contd Internal Water Tank Safety FeatureLas pilas deben reemplazarse cuando Funciones del Control RemotoBotones de Control Tecla de Encendido Encendido / Apagado58S Electrical outlet Window / Patio Door Kit InstallationPlug the unit into a 115 V / 60 Hz grounded Key Pad Functions Fig Temperature Conversion ChartAjuste del Temporizador de Apagado Automático AUTO-OFF Pantalla Instrucciones del Temporizador AutomáticoAjuste del Temporizador de Encendido Automático AUTO-ON Aparecerá en laOperating Instructions Air Conditioning Setting Time of DAY Clock InstructionsTank must be installed during air conditioning Mode Air Conditioner Operating Instructions cont’d FAN SwingMode No Intente Encender LA Unidad Compresor Durante Este Período Page Empty and re-install water tank Instrucciones DE Operación DEL Deshumidificador DRY Atención High Appear in the display window Auto-Timer InstructionsSetting the AUTO-ON Timer Swing key padParpadean. Presione los botones de ajuste hasta Instrucciones de Operación AcondicionadorDe Aire Tabla de Conversión de Temperatura Panel de Control FigAppear in the display window and the minute Setting the AUTO-ON Timer cont’dSetting the AUTO-OFF Timer During the same program Setting the AUTO-ON & AUTO-OFF timerAUTO-ON time sequence. TIMER-ON will appear Sección de deslizador. c Instalación del Kit de Ventana / Puerta de PatioCaracterística de Seguridad del Tanque de Agua Interno Instrucciones del Tanque de Agua Externo continuaciónBatteries should be replaced when Remote Control FeaturesBattery replacement Control ButtonsCool Low-Medium-High Dry Fan Remote Control Operating InstructionsTemperature Setting Press the remote Check the followingCuando el nivel de agua del tanque colector vuelve a la Instrucciones del Tanque de Agua ExternoRiesgo de Descarga Eléctrica Consejos paraAhorrar EnergíaInstalación en una Ventana s Example Remote Control Operating Instructions cont’dRemoval and Cleaning of the Air Filter Care and MaintenanceTabla Especificaciones EléctricasEste símbolo indica una advertencia IntroducciónGuarde estas instrucciones para futura referencia Limited Product Warranty Identification des pièces de l’appareil Table des matièresIdentificación de las partes de la unidad ÍndiceGarantie Limitée Conservez ces directives pour la référence future Ce symbole représente une mise en garde ou un avertissement10,8-13.6 Spécifications électriquesTableau Circuit de distribution individuel suggéréRetrait et nettoyage du filtre à air Soins et entretienFonctionnement Directives d’utilisation de la Télécommande suitePériode Temps de Risque de choc électrique Installation dans la fenêtreSuggestions pour l’économie de l’énergie Quand le niveau d’eau dans le puits revient au niveau Directives pour le réservoir d’eau externeRéglage de la vitesse du ventilateur Directives d’utilisation de la TélécommandeVérifiez ce qui suit Réglage de la températureBoutons de contrôle Caractéristiques de télécommandeRemplacement des piles Caractéristique de sécurité du réservoir d’eau interne Directives pour le réservoir d’eau externe suiteNE PAS Utiliser UNE Corde DE Rallonge Ordinaire Installation du kit de fenêtre et/ou de porte patioEN Marche Auto / Arrêt Auto Chiffres des heures clignoteront. Appuyer sur les touches RéglagedelaMINUTERIEENMARCHEAUTOsuiteRéglage de la Minuterie Arrêt Auto Tableau de conversion des températures Fonctions du bloc de touches FigRemarque importante Toute interruption de Directives d’utilisation du climatiseurRéglage de la Minuterie EN Marche Auto 34F Directives d’utilisation du climatiseur suite Directives D’UTILISATION DU Déshumidificateur Vidange directe

DPAC9030, DCAP 12030 specifications

The Danby DCAP 12030 and DPAC9030 are two popular portable air conditioners that cater to homeowners seeking efficient cooling solutions. Designed with various features and technologies, these units enhance indoor comfort while maintaining energy efficiency.

The Danby DCAP 12030 is a 12,000 BTU portable air conditioner suitable for medium-sized rooms up to 550 square feet. Its sleek design and smooth-rolling casters make it easy to move from room to room. One of its standout features is its digital display, which allows users to set the desired temperature and operate the unit with ease. This model also includes a programmable 24-hour timer, enabling users to set specific times for the unit to turn on or off. Notably, the DCAP 12030 offers three fan speeds and a dehumidification mode, helping to maintain comfortable humidity levels in your home.

On the other hand, the Danby DPAC9030 is a 9,000 BTU portable air conditioner designed for slightly smaller spaces, ideal for rooms up to 400 square feet. This unit features an impressive energy efficiency rating, which translates to lower electricity bills. The DPAC9030 incorporates a built-in dehumidifier function that removes up to 2.4 pints of moisture per hour, making it especially useful in humid climates. Its user-friendly remote control allows for seamless operation from across the room.

Both models are equipped with advanced technologies such as auto-restart functionality, which resumes operation automatically after a power outage, preventing discomfort in extreme weather. Each unit also features a washable air filter, contributing to cleaner indoor air quality by trapping dust and allergens. The compact design and integrated carry handles make both units a practical choice for users who require versatility in their HVAC systems.

In conclusion, the Danby DCAP 12030 and DPAC9030 offer a range of features and technologies designed to provide efficient cooling in portable formats. With their ease of use, energy efficiency, and effectiveness in controlling humidity levels, both models stand out as excellent choices for enhancing indoor comfort. Whether for a living room, bedroom, or even a home office, these portable air conditioners are engineered to meet the diverse needs of today’s homeowners.