Danby DCAP 12030, DPAC9030 manual Key Pad Functions Fig, Temperature Conversion Chart

Page 16

Key Pad Functions Fig. 5

The control panel on this unit “illuminates” automatically when any key pad is depressed. This “illumination” feature will “self-deactivate” (turn-off) automatically approx. 20 seconds after the last key pad is depressed.

I/O: Power Switch On / Off.

Indicator Lights:

RUN:

Blue Light illuminates to indicate selected mode is operational.

Water Full Indicator Light:

Red Light illuminates indicating the internal water tank (only) is full and/or incorrectly positioned inside

the cabinet. Fig. 6.

FAN: Selects optional fan speeds.

Fan Speed Options:

Cooling Mode: Low-Medium-High-Auto

Dry - Dehumidifying Mode: Low. (only)

Fan Mode: Low-Medium-High

CLOCK: Allows you to initiate and/or change the TIME OF DAY setting. To activate clock mode both the TIMER ON and TIMER OFF buttons must be pressed simultaneously.

TIMER ON: Used to initiate the AUTO ON start time

TIMER OFF:Used to initiate the AUTO OFF stop time

 

 

 

RUN

WATER FULL

 

I/O

MODE

FAN

SWING

 

TIMER ON TIMER OFF

 

 

 

 

TEMP/TIMER

CLOCK

 

 

 

 

ADJ

 

 

 

 

 

 

 

 

 

 

Fig. 5

Temp/Timer Adj:

:Used to adjust Time of Day Clock settings forward (1 min./1hr. increments).

Used to adjust Temperature settings forward (1°C increments).

Used to adjust Temperature settings forward (1°F increments).

Used to adjust Timer-On/Off settings forward (1min/1hr. increments)

A warning signal (beep) will sound for 20

WATER FULL seconds and the Water Full indicator light will illuminate.

TEMP/

AD

Fig. 6

: Used to adjust Time of Day Clock settings backward (1 min/1hr. increments).

Used to adjust Temperature settings backward (1°C increments).

Used to adjust Temperature settings backward (1°F increments).

Used to adjust Timer -On/Off settings backward (1min/1hr. increments)

SWING: Allows the vertical louver grills to oscillate from side to side automatically.

Temperature Conversion Chart

°C

10

11

12

13

14

15

16

17

18

19

20

21

°F

50

52

54

55

57

59

61

63

64

66

68

70

 

 

 

 

 

 

 

 

 

 

 

 

 

°C

22

23

24

25

26

27

28

29

30

31

32

33

°F

72

73

75

77

79

81

82

84

86

88

90

91

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: This appliance provides a feature that will allow you the option of setting “temperatures” in “Celsius” or “Fahrenheit”. To change the temperature display on the main unit, press both the (Temp/Timer ADJ) keypads “simultaneously” to alternate between the C & F scale

Celisus scale allows adjustments in increments of 1˚C Farenheight scale allows adjustments in increments of 1˚F

8

Image 16
Contents 800-26- R Portable 3 Season Home ComfortAppareil de confort au foyer portable 3 saisons Confort Hogareño Portátil de 3 EstacionesManuel ’UTILISATION Manual DEL Usuario Table Of Contents Unit Parts IdentificationIntroduction This symbol denotes a caution or warningKeep these instructions for future reference Garantía Limitada Cuidado y Mantenimiento Remoción y Limpieza del Filtro de AireElectrical Specifications Unit Specifications Model DPAC9030 DPAC12030Power Consumption Suggested Individual Branch CircuitEnergy-Saving Tips Window InstallationElectric Shock Hazard Instrucciones de Operación del Control Remoto continuación Sleep Modo Nocturno Nota LaPeríodo Operación Aumento de temperatura De operación programadaInstrucciones de Operación del Control Remoto Verifique lo siguienteAjuste de Temperatura Presione los botones Velocidad del VentiladorExternal Water Tank Feature External Water Tank InstructionsInternal Water Tank Safety Feature External Water Tank Instructions contdFunciones del Control Remoto Botones de ControlTecla de Encendido Encendido / Apagado Las pilas deben reemplazarse cuando58S Plug the unit into a 115 V / 60 Hz grounded Window / Patio Door Kit InstallationElectrical outlet Temperature Conversion Chart Key Pad Functions FigAjuste del Temporizador de Apagado Automático AUTO-OFF Instrucciones del Temporizador Automático Ajuste del Temporizador de Encendido Automático AUTO-ONAparecerá en la PantallaTank must be installed during air conditioning Mode Setting Time of DAY Clock InstructionsOperating Instructions Air Conditioning FAN Swing Air Conditioner Operating Instructions cont’dMode No Intente Encender LA Unidad Compresor Durante Este Período Page Empty and re-install water tank Instrucciones DE Operación DEL Deshumidificador DRY Atención High Auto-Timer Instructions Setting the AUTO-ON TimerSwing key pad Appear in the display windowDe Aire Instrucciones de Operación AcondicionadorParpadean. Presione los botones de ajuste hasta Panel de Control Fig Tabla de Conversión de TemperaturaSetting the AUTO-OFF Timer Setting the AUTO-ON Timer cont’dAppear in the display window and the minute AUTO-ON time sequence. TIMER-ON will appear Setting the AUTO-ON & AUTO-OFF timerDuring the same program Instalación del Kit de Ventana / Puerta de Patio Sección de deslizador. cInstrucciones del Tanque de Agua Externo continuación Característica de Seguridad del Tanque de Agua InternoRemote Control Features Battery replacementControl Buttons Batteries should be replaced whenRemote Control Operating Instructions Temperature Setting Press the remoteCheck the following Cool Low-Medium-High Dry FanInstrucciones del Tanque de Agua Externo Cuando el nivel de agua del tanque colector vuelve a laInstalación en una Ventana s Consejos paraAhorrar EnergíaRiesgo de Descarga Eléctrica Remote Control Operating Instructions cont’d ExampleCare and Maintenance Removal and Cleaning of the Air FilterEspecificaciones Eléctricas TablaGuarde estas instrucciones para futura referencia IntroducciónEste símbolo indica una advertencia Limited Product Warranty Table des matières Identification des pièces de l’appareilÍndice Identificación de las partes de la unidadGarantie Limitée Ce symbole représente une mise en garde ou un avertissement Conservez ces directives pour la référence futureSpécifications électriques TableauCircuit de distribution individuel suggéré 10,8-13.6Soins et entretien Retrait et nettoyage du filtre à airPériode Temps de Directives d’utilisation de la Télécommande suiteFonctionnement Suggestions pour l’économie de l’énergie Installation dans la fenêtreRisque de choc électrique Directives pour le réservoir d’eau externe Quand le niveau d’eau dans le puits revient au niveauDirectives d’utilisation de la Télécommande Vérifiez ce qui suitRéglage de la température Réglage de la vitesse du ventilateurRemplacement des piles Caractéristiques de télécommandeBoutons de contrôle Directives pour le réservoir d’eau externe suite Caractéristique de sécurité du réservoir d’eau interneInstallation du kit de fenêtre et/ou de porte patio NE PAS Utiliser UNE Corde DE Rallonge OrdinaireEN Marche Auto / Arrêt Auto Réglage de la Minuterie Arrêt Auto RéglagedelaMINUTERIEENMARCHEAUTOsuiteChiffres des heures clignoteront. Appuyer sur les touches Fonctions du bloc de touches Fig Tableau de conversion des températuresDirectives d’utilisation du climatiseur Remarque importante Toute interruption deRéglage de la Minuterie EN Marche Auto 34F Directives d’utilisation du climatiseur suite Directives D’UTILISATION DU Déshumidificateur Vidange directe

DPAC9030, DCAP 12030 specifications

The Danby DCAP 12030 and DPAC9030 are two popular portable air conditioners that cater to homeowners seeking efficient cooling solutions. Designed with various features and technologies, these units enhance indoor comfort while maintaining energy efficiency.

The Danby DCAP 12030 is a 12,000 BTU portable air conditioner suitable for medium-sized rooms up to 550 square feet. Its sleek design and smooth-rolling casters make it easy to move from room to room. One of its standout features is its digital display, which allows users to set the desired temperature and operate the unit with ease. This model also includes a programmable 24-hour timer, enabling users to set specific times for the unit to turn on or off. Notably, the DCAP 12030 offers three fan speeds and a dehumidification mode, helping to maintain comfortable humidity levels in your home.

On the other hand, the Danby DPAC9030 is a 9,000 BTU portable air conditioner designed for slightly smaller spaces, ideal for rooms up to 400 square feet. This unit features an impressive energy efficiency rating, which translates to lower electricity bills. The DPAC9030 incorporates a built-in dehumidifier function that removes up to 2.4 pints of moisture per hour, making it especially useful in humid climates. Its user-friendly remote control allows for seamless operation from across the room.

Both models are equipped with advanced technologies such as auto-restart functionality, which resumes operation automatically after a power outage, preventing discomfort in extreme weather. Each unit also features a washable air filter, contributing to cleaner indoor air quality by trapping dust and allergens. The compact design and integrated carry handles make both units a practical choice for users who require versatility in their HVAC systems.

In conclusion, the Danby DCAP 12030 and DPAC9030 offer a range of features and technologies designed to provide efficient cooling in portable formats. With their ease of use, energy efficiency, and effectiveness in controlling humidity levels, both models stand out as excellent choices for enhancing indoor comfort. Whether for a living room, bedroom, or even a home office, these portable air conditioners are engineered to meet the diverse needs of today’s homeowners.