Danby DPAC9030, DCAP 12030 manual Setting the AUTO-ON Timer cont’d, Setting the AUTO-OFF Timer

Page 31

Setting the AUTO-ON TIMER (cont’d)

5)All of the settings are now registered.

6)To set the AUTO-ONtimer, the unit must be turned “off” (non-operational).

7)Press the TIMER-ONkey pad to initiate the AUTO-ONtime sequence. TIMER-ON will

appear in the display window and the “minute”

digits start to flash. Press either or TEMP/TIME ADJ keys to select the AUTO-ON “minutes”. Press the TIMER-ON key pad again

and the “hour” digits start to flash. Press the

or TEMP/TIME ADJ key pad to select the AUTO- ON “hour” start time. Press the TIMER- ON key pad again and the display will stipulate, CLOCK / ON / and the set AUTO-ON time. Press the clock buttons (TIME-ON / TIMER-OFF) simultaneously to revert back to the current time of day clock setting. The unit will start automatically at the specified AUTO-ONset time. To cancel or override the AUTO-ONprogram, simply turn on the unit anytime prior to the AUTO-ONtime is scheduled to operate.You can varify the AUTO-ONtime selected anytime (prior to the program starting) by pressing the TIMER- ON key pad. The time you selected will appear in the display.

Setting the AUTO-OFF TIMER

Before setting the AUTO-OFFtimer, the time of day clock must be set/operational.

1)To set the AUTO-OFFtimer, the unit must be (operational) turned on. (I/O switch)

2)Press the TIMER-OFFkey pad to initiate the AUTO-OFFtime sequence. TIMER-OFF will

appear in the display window and the “minute” digits start to flash.Press theor TEMP/TIME ADJ key pad to select the AUTO- OFF “minute”time. Press the TIMER-OFF key pad again and the “hour” digits start to flash.

Press the or TEMP/TIME ADJ key pad to select the AUTO-OFF “hour” stop time. Press the TIMER-OFF key pad again and the display will stipulate, CLOCK / OFF / and the set AUTO- OFF time. Press the clock buttons (TIMER-ON / TIMER-OFF) simultaneously to revert back to the current time of day clock setting. The unit will stop automatically at the specified AUTO-OFF time. To cancel or override the AUTO-OFFprogram, simply turn off the unit anytime prior to the AUTO-OFFtime is scheduled to operate.

15

Image 31
Contents Confort Hogareño Portátil de 3 Estaciones 800-26- RPortable 3 Season Home Comfort Appareil de confort au foyer portable 3 saisonsManuel ’UTILISATION Manual DEL Usuario Unit Parts Identification Table Of ContentsIntroduction This symbol denotes a caution or warningKeep these instructions for future reference Garantía Limitada Remoción y Limpieza del Filtro de Aire Cuidado y MantenimientoSuggested Individual Branch Circuit Electrical SpecificationsUnit Specifications Model DPAC9030 DPAC12030 Power ConsumptionEnergy-Saving Tips Window InstallationElectric Shock Hazard De operación programada Instrucciones de Operación del Control Remoto continuaciónSleep Modo Nocturno Nota La Período Operación Aumento de temperaturaVelocidad del Ventilador Instrucciones de Operación del Control RemotoVerifique lo siguiente Ajuste de Temperatura Presione los botonesExternal Water Tank Instructions External Water Tank FeatureExternal Water Tank Instructions contd Internal Water Tank Safety FeatureLas pilas deben reemplazarse cuando Funciones del Control RemotoBotones de Control Tecla de Encendido Encendido / Apagado58S Plug the unit into a 115 V / 60 Hz grounded Window / Patio Door Kit InstallationElectrical outlet Key Pad Functions Fig Temperature Conversion ChartAjuste del Temporizador de Apagado Automático AUTO-OFF Pantalla Instrucciones del Temporizador AutomáticoAjuste del Temporizador de Encendido Automático AUTO-ON Aparecerá en laTank must be installed during air conditioning Mode Setting Time of DAY Clock InstructionsOperating Instructions Air Conditioning Air Conditioner Operating Instructions cont’d FAN SwingMode No Intente Encender LA Unidad Compresor Durante Este Período Page Empty and re-install water tank Instrucciones DE Operación DEL Deshumidificador DRY Atención High Appear in the display window Auto-Timer InstructionsSetting the AUTO-ON Timer Swing key padDe Aire Instrucciones de Operación AcondicionadorParpadean. Presione los botones de ajuste hasta Tabla de Conversión de Temperatura Panel de Control FigSetting the AUTO-OFF Timer Setting the AUTO-ON Timer cont’dAppear in the display window and the minute AUTO-ON time sequence. TIMER-ON will appear Setting the AUTO-ON & AUTO-OFF timerDuring the same program Sección de deslizador. c Instalación del Kit de Ventana / Puerta de PatioCaracterística de Seguridad del Tanque de Agua Interno Instrucciones del Tanque de Agua Externo continuaciónBatteries should be replaced when Remote Control FeaturesBattery replacement Control ButtonsCool Low-Medium-High Dry Fan Remote Control Operating InstructionsTemperature Setting Press the remote Check the followingCuando el nivel de agua del tanque colector vuelve a la Instrucciones del Tanque de Agua ExternoInstalación en una Ventana s Consejos paraAhorrar EnergíaRiesgo de Descarga Eléctrica Example Remote Control Operating Instructions cont’dRemoval and Cleaning of the Air Filter Care and MaintenanceTabla Especificaciones EléctricasGuarde estas instrucciones para futura referencia IntroducciónEste símbolo indica una advertencia Limited Product Warranty Identification des pièces de l’appareil Table des matièresIdentificación de las partes de la unidad ÍndiceGarantie Limitée Conservez ces directives pour la référence future Ce symbole représente une mise en garde ou un avertissement10,8-13.6 Spécifications électriquesTableau Circuit de distribution individuel suggéréRetrait et nettoyage du filtre à air Soins et entretienPériode Temps de Directives d’utilisation de la Télécommande suiteFonctionnement Suggestions pour l’économie de l’énergie Installation dans la fenêtreRisque de choc électrique Quand le niveau d’eau dans le puits revient au niveau Directives pour le réservoir d’eau externeRéglage de la vitesse du ventilateur Directives d’utilisation de la TélécommandeVérifiez ce qui suit Réglage de la températureRemplacement des piles Caractéristiques de télécommandeBoutons de contrôle Caractéristique de sécurité du réservoir d’eau interne Directives pour le réservoir d’eau externe suiteNE PAS Utiliser UNE Corde DE Rallonge Ordinaire Installation du kit de fenêtre et/ou de porte patioEN Marche Auto / Arrêt Auto Réglage de la Minuterie Arrêt Auto RéglagedelaMINUTERIEENMARCHEAUTOsuiteChiffres des heures clignoteront. Appuyer sur les touches Tableau de conversion des températures Fonctions du bloc de touches FigRemarque importante Toute interruption de Directives d’utilisation du climatiseurRéglage de la Minuterie EN Marche Auto 34F Directives d’utilisation du climatiseur suite Directives D’UTILISATION DU Déshumidificateur Vidange directe

DPAC9030, DCAP 12030 specifications

The Danby DCAP 12030 and DPAC9030 are two popular portable air conditioners that cater to homeowners seeking efficient cooling solutions. Designed with various features and technologies, these units enhance indoor comfort while maintaining energy efficiency.

The Danby DCAP 12030 is a 12,000 BTU portable air conditioner suitable for medium-sized rooms up to 550 square feet. Its sleek design and smooth-rolling casters make it easy to move from room to room. One of its standout features is its digital display, which allows users to set the desired temperature and operate the unit with ease. This model also includes a programmable 24-hour timer, enabling users to set specific times for the unit to turn on or off. Notably, the DCAP 12030 offers three fan speeds and a dehumidification mode, helping to maintain comfortable humidity levels in your home.

On the other hand, the Danby DPAC9030 is a 9,000 BTU portable air conditioner designed for slightly smaller spaces, ideal for rooms up to 400 square feet. This unit features an impressive energy efficiency rating, which translates to lower electricity bills. The DPAC9030 incorporates a built-in dehumidifier function that removes up to 2.4 pints of moisture per hour, making it especially useful in humid climates. Its user-friendly remote control allows for seamless operation from across the room.

Both models are equipped with advanced technologies such as auto-restart functionality, which resumes operation automatically after a power outage, preventing discomfort in extreme weather. Each unit also features a washable air filter, contributing to cleaner indoor air quality by trapping dust and allergens. The compact design and integrated carry handles make both units a practical choice for users who require versatility in their HVAC systems.

In conclusion, the Danby DCAP 12030 and DPAC9030 offer a range of features and technologies designed to provide efficient cooling in portable formats. With their ease of use, energy efficiency, and effectiveness in controlling humidity levels, both models stand out as excellent choices for enhancing indoor comfort. Whether for a living room, bedroom, or even a home office, these portable air conditioners are engineered to meet the diverse needs of today’s homeowners.