Danby DPAC9030, DCAP 12030 manual

Page 23

DRY (Dehumidifier) Operating Instructions

NOTE: The exhaust hoses do not have to be installed during dehumidifier mode.

Both internal and external water tanks must be installed during dehumidifer mode.

1)Press the I/O (on/off) key pad to switch on the unit.

2)Press the MODE key until the word DRY (Dehumidifying) appears in the display window. Each depression of the MODE key will advance to a different mode setting (Cool-Dry-Fan).

3)Press the appropriate (TEMP / TIMER ADJ) key to select a (relative humidity) operating setting between 35% ~ 90% RH (adjustable in increments of 5%)

For continuous (non-stop) dehumidifer operation

press the (TEMP / TIMER ADJ) key pad until the symbol “- - “ appears in the display window.

NOTE: The compressor will not cycle off during “continuous” mode.

The set relative humidity level will flash in the display window for approximately 5 seconds then automatically revert back to display actual room ambient relative humidity conditions. NOTE: The set operating RH level must be programed within the 5 second (flashing) condition. To view the “set” relative humidity program any time, press either of the TEMP/TIMER ADJ buttons.

NOTE: There is no fan speed adjustment during dehumidifying mode. (the fan speed is factory set for “low”)

The blue (RUN) indicator light illuminates indicating dehumidifying mode is operational (there may be a slight delay of 10-30 seconds before the cycle begins, this is normal).

IMPORTANT: The relative humidity setting selected should always be set a few degrees lower than the room ambient relative humidity conditions, to ensure normal dehumidifying operation. NOTE: it is not recommended to operate your Dehumidifier, below temperatures of 15.5°C (60°F), this could result in icing-up conditions of the evaporator coils, and minimize efficiency.

4)Condensed water will be accumulated in the external / internal water tanks. When the external tank is full, water will backflow into the internal tank. When the internal tank is full, the unit will alarm (beep) for 20 deconds and the Water Full indicator light will illuminate. At this time dehumidification will stop immediately. However, the fan motor will continue to operate (this is normal). Carefully remove both water tanks from the cabinet, dispose of the water. Replace the water tanks back to their original positions and the Dehumidifying process will automatically resume. It may take 3-5 minutes for the compressor to re-start. This is normal.

5)This unit also has provisions for a continuous “drain” option (for basement applications having a floor drain). The required drain hose extension is not included with this unit. It can be purchased through any local Hardware Store. Drain Hose Specifications: Standard garden hose.

For continuous direct drain operation. Remove (unscrew) the drain cap at the back of the cabinet located directly above the external tank quick connect. Attach suitable length (of garden hose) to the direct drain fitting. (do not over tighten) Position the open end of the drain hose as close as possible to the floor drain. Check the hose connection for leaks.

NOTE: Direct drain operation is intended for floor drain applications only. Direct drain operation should not be used in stem pipe and/or sink applications.

11

Image 23
Contents Confort Hogareño Portátil de 3 Estaciones 800-26- RPortable 3 Season Home Comfort Appareil de confort au foyer portable 3 saisonsManuel ’UTILISATION Manual DEL Usuario Unit Parts Identification Table Of ContentsKeep these instructions for future reference This symbol denotes a caution or warningIntroduction Garantía Limitada Remoción y Limpieza del Filtro de Aire Cuidado y MantenimientoSuggested Individual Branch Circuit Electrical SpecificationsUnit Specifications Model DPAC9030 DPAC12030 Power ConsumptionElectric Shock Hazard Window InstallationEnergy-Saving Tips De operación programada Instrucciones de Operación del Control Remoto continuaciónSleep Modo Nocturno Nota La Período Operación Aumento de temperaturaVelocidad del Ventilador Instrucciones de Operación del Control RemotoVerifique lo siguiente Ajuste de Temperatura Presione los botonesExternal Water Tank Instructions External Water Tank FeatureExternal Water Tank Instructions contd Internal Water Tank Safety FeatureLas pilas deben reemplazarse cuando Funciones del Control RemotoBotones de Control Tecla de Encendido Encendido / Apagado58S Electrical outlet Window / Patio Door Kit InstallationPlug the unit into a 115 V / 60 Hz grounded Key Pad Functions Fig Temperature Conversion ChartAjuste del Temporizador de Apagado Automático AUTO-OFF Pantalla Instrucciones del Temporizador AutomáticoAjuste del Temporizador de Encendido Automático AUTO-ON Aparecerá en laOperating Instructions Air Conditioning Setting Time of DAY Clock InstructionsTank must be installed during air conditioning Mode Air Conditioner Operating Instructions cont’d FAN SwingMode No Intente Encender LA Unidad Compresor Durante Este Período Page Empty and re-install water tank Instrucciones DE Operación DEL Deshumidificador DRY Atención High Appear in the display window Auto-Timer InstructionsSetting the AUTO-ON Timer Swing key padParpadean. Presione los botones de ajuste hasta Instrucciones de Operación AcondicionadorDe Aire Tabla de Conversión de Temperatura Panel de Control FigAppear in the display window and the minute Setting the AUTO-ON Timer cont’dSetting the AUTO-OFF Timer During the same program Setting the AUTO-ON & AUTO-OFF timerAUTO-ON time sequence. TIMER-ON will appear Sección de deslizador. c Instalación del Kit de Ventana / Puerta de PatioCaracterística de Seguridad del Tanque de Agua Interno Instrucciones del Tanque de Agua Externo continuaciónBatteries should be replaced when Remote Control FeaturesBattery replacement Control ButtonsCool Low-Medium-High Dry Fan Remote Control Operating InstructionsTemperature Setting Press the remote Check the followingCuando el nivel de agua del tanque colector vuelve a la Instrucciones del Tanque de Agua ExternoRiesgo de Descarga Eléctrica Consejos paraAhorrar EnergíaInstalación en una Ventana s Example Remote Control Operating Instructions cont’dRemoval and Cleaning of the Air Filter Care and MaintenanceTabla Especificaciones EléctricasEste símbolo indica una advertencia IntroducciónGuarde estas instrucciones para futura referencia Limited Product Warranty Identification des pièces de l’appareil Table des matièresIdentificación de las partes de la unidad ÍndiceGarantie Limitée Conservez ces directives pour la référence future Ce symbole représente une mise en garde ou un avertissement10,8-13.6 Spécifications électriquesTableau Circuit de distribution individuel suggéréRetrait et nettoyage du filtre à air Soins et entretienFonctionnement Directives d’utilisation de la Télécommande suitePériode Temps de Risque de choc électrique Installation dans la fenêtreSuggestions pour l’économie de l’énergie Quand le niveau d’eau dans le puits revient au niveau Directives pour le réservoir d’eau externeRéglage de la vitesse du ventilateur Directives d’utilisation de la TélécommandeVérifiez ce qui suit Réglage de la températureBoutons de contrôle Caractéristiques de télécommandeRemplacement des piles Caractéristique de sécurité du réservoir d’eau interne Directives pour le réservoir d’eau externe suiteNE PAS Utiliser UNE Corde DE Rallonge Ordinaire Installation du kit de fenêtre et/ou de porte patioEN Marche Auto / Arrêt Auto Chiffres des heures clignoteront. Appuyer sur les touches RéglagedelaMINUTERIEENMARCHEAUTOsuiteRéglage de la Minuterie Arrêt Auto Tableau de conversion des températures Fonctions du bloc de touches FigRemarque importante Toute interruption de Directives d’utilisation du climatiseurRéglage de la Minuterie EN Marche Auto 34F Directives d’utilisation du climatiseur suite Directives D’UTILISATION DU Déshumidificateur Vidange directe

DPAC9030, DCAP 12030 specifications

The Danby DCAP 12030 and DPAC9030 are two popular portable air conditioners that cater to homeowners seeking efficient cooling solutions. Designed with various features and technologies, these units enhance indoor comfort while maintaining energy efficiency.

The Danby DCAP 12030 is a 12,000 BTU portable air conditioner suitable for medium-sized rooms up to 550 square feet. Its sleek design and smooth-rolling casters make it easy to move from room to room. One of its standout features is its digital display, which allows users to set the desired temperature and operate the unit with ease. This model also includes a programmable 24-hour timer, enabling users to set specific times for the unit to turn on or off. Notably, the DCAP 12030 offers three fan speeds and a dehumidification mode, helping to maintain comfortable humidity levels in your home.

On the other hand, the Danby DPAC9030 is a 9,000 BTU portable air conditioner designed for slightly smaller spaces, ideal for rooms up to 400 square feet. This unit features an impressive energy efficiency rating, which translates to lower electricity bills. The DPAC9030 incorporates a built-in dehumidifier function that removes up to 2.4 pints of moisture per hour, making it especially useful in humid climates. Its user-friendly remote control allows for seamless operation from across the room.

Both models are equipped with advanced technologies such as auto-restart functionality, which resumes operation automatically after a power outage, preventing discomfort in extreme weather. Each unit also features a washable air filter, contributing to cleaner indoor air quality by trapping dust and allergens. The compact design and integrated carry handles make both units a practical choice for users who require versatility in their HVAC systems.

In conclusion, the Danby DCAP 12030 and DPAC9030 offer a range of features and technologies designed to provide efficient cooling in portable formats. With their ease of use, energy efficiency, and effectiveness in controlling humidity levels, both models stand out as excellent choices for enhancing indoor comfort. Whether for a living room, bedroom, or even a home office, these portable air conditioners are engineered to meet the diverse needs of today’s homeowners.