Heatcraft Refrigeration Products HCS manual Net Weights and Metal Gauges, Weight in pounds

Page 39

Net Weights and Metal Gauges

Air Handler Component

 

 

 

 

 

 

 

Unit Size

 

 

 

 

 

 

 

Weight in pounds

 

03

06

08

10

12

14

18

20

26

34

41

50

65

75

 

 

HCS

 

short

FC

290

430

500

550

650

790

816

836

968

1188

1386

 

 

 

Fan

 

HCS

 

short

AF

 

 

 

 

 

 

 

946

1177

1518

1782

2700

3300

4496

 

 

HCL

 

long

FC

318

450

553

600

732

988

1033

1067

1221

1474

1672

 

 

 

and

 

HCL

 

long

AF

 

 

 

 

 

 

 

1177

1430

1793

2057

2850

3480

4690

 

 

VCS

 

vertical

FC

296

387

482

535

615

860

1004

1111

1254

1628

1881

 

 

 

Coil

 

HD

heating duty

FC

170

280

312

360

450

510

564

605

693

902

1078

 

 

 

 

 

HD

heating duty

AF

 

 

 

 

 

 

 

715

891

1221

1474

2600

3200

3359

Sections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flat - TA & Pleated 2"

60

73

83

95

99

104

106

108

115

160

185

255

315

384

 

 

Flat - Permanent 2"

66

79

89

101

106

114

126

135

165

240

275

390

460

560

Filter

 

 

Flat - Pleated 4"

 

75

88

98

110

119

124

126

127

130

185

210

298

351

428

 

 

High Capacity - TA & Pleated

149

168

187

206

215

224

230

234

244

260

290

360

440

535

Sections

 

High Capacity - Permanent

155

176

196

216

225

234

240

244

254

365

450

520

650

790

 

 

High Efficiency - 22" Section

82

95

112

133

133

153

175

180

194

235

248

269

330

359

 

 

High Efficiency - 28" Section

103

121

143

170

170

196

225

224

246

296

318

345

425

463

 

 

High Efficiency - 44" Section

127

150

173

201

201

230

264

274

299

358

380

412

516

552

 

 

 

 

Mixbox

 

174

195

216

224

236

247

254

260

300

430

550

680

800

975

Other

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessory

 

Internal Face and Bypass

52

68

79

100

115

138

148

155

180

260

350

420

520

634

Sections

 

External Face and Bypass

57

75

87

110

128

155

166

175

200

286

385

462

650

793

 

 

Auxiliary Coil Module HCS

129

164

204

208

223

306

280

261

310

331

362

515

640

1305

 

 

Auxillary Coil Module HCL

157

184

257

258

305

504

497

492

563

617

648

665

820

1499

 

 

 

Electric Heater

 

199

218

237

266

285

294

310

314

324

355

390

485

590

685

 

 

 

 

1

Row

36

55

70

80

94

106

110

112

144

195

239

339

406

538

 

 

 

 

2

Row

50

80

101

120

143

164

169

173

228

318

396

562

673

891

Large

 

Type 5

 

3

Row

64

106

134

161

195

223

231

236

314

444

557

737

936

1168

 

 

 

 

4

Row

78

132

168

202

246

282

292

299

398

569

718

913

1199

1445

Coils

 

10 FPI

 

6

Row

109

187

240

290

353

408

422

432

578

830

1052

1278

1677

2017

 

 

 

 

8

Row

141

242

311

379

461

534

552

565

760

1092

1385

1638

2154

2589

 

 

 

 

10

Row

172

297

383

467

569

659

682

699

942

1355

1718

2194

2893

3478

(Coil weights

include the weight of water when filled)

 

 

 

 

 

 

 

 

 

 

 

 

TA=

Throw away type filters

AF=

Airfoil Fan

FC=

Forward Curved fan

Double wall construction add 45% to fan & Coil section or accessory

 

 

To estimate weights for other coils:

 

For

Type A:

multiply type 5 coil weight

by

0.800

For

Small coil :

multiply large coil weight

by

0.823

 

 

 

 

 

 

For

14 FPI:

multiply 10 FPI

coil weight

by

1.121

For

12 FPI:

multiply 10 FPI

coil weight

by

1.065

For

8 FPI:

multiply 10 FPI

coil weight

by

0.935

For

6 FPI:

multiply 10 FPI

coil weight

by

0.915

 

 

 

 

 

 

Air Handler Motor And Drive

 

 

Motor Horsepower, 1800 RPM

 

 

 

 

 

 

 

 

Weight in pounds

1

1.5 -2

3

5

7.5

 

10

 

15

20

25

30

40

50

 

 

Motor &

High Efficiency Open Single Speed

67

74

114

127

209

 

216

 

341

384

396

427

621

623

 

 

Drive

Totally Enclosed Fan Cooled (TEFC)

56

71

88

104

178

 

194

 

275

336

411

461

624

670

 

 

Weight

 

Open 2 Speed, 2 Winding

71

97

115

160

291

 

267

 

368

356

366

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Handler Panels And Frames

 

 

 

 

 

Unit Size

 

 

 

 

 

 

 

 

Description, metal gauge

03

06

08

10

12

 

14

 

18

20

26

34

41

50

65

75

 

 

Frame

12

12

12

12

12

 

12

 

12

12

12

12

12

10

10

10

Fan

 

Fan Panel

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

Section

 

Side Panel

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

 

 

Bottom Panel

14

14

14

14

14

 

14

 

14

16

16

16

16

16

16

16

 

 

Frame

14

14

14

14

14

 

14

 

14

14

14

14

14

10

10

10

Coil

 

Top Panel

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

Section

 

Bottom Panel

14

14

14

14

14

 

14

 

14

16

16

16

16

16

16

16

 

 

Drain Panel

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

Accessory

 

Filter Section Casings

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

Sections

 

Economizer Casings

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

 

 

Damper Blades

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

Others

 

Removable Panels

16

16

16

16

16

 

16

 

16

16

16

16

16

16

16

16

 

 

Base Rails

10

10

10

10

10

 

10

 

10

10

10

10

10

08

08

08

39

Image 39
Contents Air Handlers Quality Standard IndexCabinet style Fan Type NomenclatureStandard Unit Features Heat Reclaim Coils Air Handler CoilsDirect Expansion Coils Water CoilsAccessories- Electric Heat Construction & DimensionsUnit Heater Dimensions Size Electric Heater Selection Example Maximum KWComponent 208 240 460 480 Accessories Filters And Auxiliary Sections Auxilary Sections- All unit Sizes Dimensions, Page 29 to‘A’ = Available Accessories for Fan and Coil SectionsAvailable Motors, Drives, Motor Starters per Horsepower Motor Drive Starter Motor Horsepower DescriptionSelection Conditions Air Handler SelectionSelection Example Selection ProcedureCu m/h Air volume at Air handler DX air Refrigerant Chilled waterAir Handler Performance Quick Reference SteamCoil Air Handler Performance- Direct Expansion1553 Saturated Suction TemperatureAir Handler Perfromance- Direct Expansion 1339Air Handler Performance- Chilled Water Row CoilsSize Air Area Std Face Air Handler Perfromance- Chilled WaterHeating 0F. Air Air Handler Performance- Hot Water/SteamTwo Row One Row Heating 60F. AirSize Air Sq. Ft One Row Two RowTemperature Difference Coil Perfromance- Heat Reclaim MBH/SQ FTType a and Type 5, hot gas reclaim, heating capacities 400 450 500 550 600 Refrigerant Evaporating Temperature FCoil Performance- Direct Expansion MBH/SQ FT Actual capacity will vary With coil circuitingFPM, Type a Coils 1/2 DIA FPM, Type 5 Coils 5/8 DIA Coil Perfromance- Chilled Water MBH/SQ FTChilled RowsFPM, Type 8 Coils 1 DIA Rows Coil Performance- Heating, Water & SteamFPM, Type 5 Coils 5/8 DIA Rows 500 600 650 700 400Size Fan PerformanceCoil Total RPM BHP Size 14 and SizeSize 20 and Size 32 3/8 Airfoil Fan High Efficiency Filter Section High Efficiency Filter Sections- DimensionsDimensions inches Size 65 and SizeSizes 03 Sizes 20 Accessory Flange PatternDimensions Size Mixbox Inlet Duct ConnectionsMotor and coil connection DimensionsReference Mix boxDischarge Sizes 03 41 FCSizes 50 75 AF Mixbox For All Units Sizes10 1/8 12 5/8 Rows 15 5/8‘D’ added to Depth is dimensionDimension ‘T’ Sizes 50 65 AFSizes 03 Mounting Locations For Vibration Isolators For All Unit SizesSize Edge For All Unit Sizes All mounting holes are 5/8 inch diameter Rows Inch filtersOne and two row heating coils do not have Air Flow Reheat Position Preheat Position Coil SectionVibration Isolators, Quantity Required ModelsAir Handler Component Unit Size Net Weights and Metal GaugesWeight in pounds To estimate weights for other coilsFace Area Air Handler Unit Size Square Feet Face Areas- Air Pressure Drops, Dry CoilsAir Pressure Drops- Cabinets, Filters, Wet Coils Depth Flat & hi 35% Efficient , PleatedFin Air Velocity Feet Per minute Physical Data 16.04 21.25 27.63 31.88 40.50 51.67 59.42 Unit SizeCFM Range Cooling 19.25 25.50 34.00 40.38 49.50 64.58 74.91 SmallMechanical Specification