Heatcraft Refrigeration Products HCS Coil Section, Vibration Isolators, Quantity Required, Models

Page 38

Dimensions

Coil Section

Models

Models

Models

HCS - HCL- VCS

HCS - HCL

HCS - HCL - VCS

Air

Flow

 

Reheat Position

 

Reheat Position

Preheat Position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil Casing Depth - Inches

 

 

 

 

 

 

 

 

Type

Hot Water & Steam

 

RHR & DX

 

 

 

 

RHR, DX, Water

 

 

Rows

1

 

2

 

1

2

 

3

 

4

 

5

 

6

 

8

10

Depth

3 1/4

 

3 1/4

 

7

7

 

7

 

7

 

9 3/4

9 3/4

12 1/2

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overall Section Depth

 

 

Maximum Coil Space

 

 

 

 

 

 

 

 

Unit

 

 

A

 

 

 

 

B

 

 

 

 

 

 

 

 

Size

 

HCS

HCL

 

VCS

 

HCS

 

HCL

 

VCS

 

 

 

 

 

 

03-06

22 1/4

28 11/16

 

28 11/16

15 1/2

21

 

18 3/4

 

 

 

 

 

 

 

08-10

22 1/4

35 1/2

 

35 1/2

15 1/2

28

 

18 3/4

 

 

 

 

 

 

 

12-18

22 1/4

38 3/4

 

38 3/4

15 1/2

31

 

18 3/4

 

 

 

 

 

 

 

20

22 1/4

44 5/8

 

42 1/8

15 1/2

37

 

18 3/4

 

 

 

 

 

 

 

26

22 1/4

44 5/8

 

44 1/8

15 1/2

37

 

18 3/4

 

 

 

 

 

 

 

34

22 1/4

44 5/8

 

54 1/8

15 1/2

37

 

18 3/4

 

 

 

 

 

 

 

41

22 1/4

44 5/8

 

62 1/8

15 1/2

37

 

18 3/4

 

 

 

 

 

 

 

50-75

23 1/4

41 1/2

 

15 1/2

33 3/4

 

 

 

 

All dimensions are in inches.

Vibration Isolators, Quantity Required

Order either rubber in shear (RIS) or 1" deflection spring isolators as accessories. Isolators are shipped loose, see pages 36 and 37 for isolator location points, see page 3 for ceiling versus platform mounting per unit size:

Cabinet types

Unit size

Quantity

 

Accessory sections (All sizes):

Quantity

HCS or HCL models

03 - 18

4

 

 

required

HCS or HCL models

20 - 75

6

 

High capacity filter section

2

VCS models

03 - 41

4

 

Economizer section, combined with filters or without filters

2

HD models

03 - 75

4

 

Access section

2

 

 

 

 

Auxiliary coil section (either HCS or HCL )

4

 

 

 

 

Electric preheat section

2

 

 

 

 

High efficiency filter section

2

 

 

 

 

 

 

38

Image 38
Contents Air Handlers Index Quality StandardNomenclature Cabinet style Fan TypeStandard Unit Features Water Coils Air Handler CoilsDirect Expansion Coils Heat Reclaim CoilsUnit Heater Dimensions Size Accessories- Electric HeatConstruction & Dimensions Component 208 240 460 480 Electric Heater Selection ExampleMaximum KW Accessories Auxilary Sections- All unit Sizes Dimensions, Page 29 to Filters And Auxiliary SectionsMotor Drive Starter Motor Horsepower Description Accessories for Fan and Coil SectionsAvailable Motors, Drives, Motor Starters per Horsepower ‘A’ = AvailableAir Handler Selection Selection ConditionsSelection Procedure Selection ExampleSteam Air volume at Air handler DX air Refrigerant Chilled waterAir Handler Performance Quick Reference Cu m/hAir Handler Performance- Direct Expansion Coil1339 Saturated Suction TemperatureAir Handler Perfromance- Direct Expansion 1553Size Air Area Air Handler Performance- Chilled WaterRow Coils Air Handler Perfromance- Chilled Water Std FaceAir Handler Performance- Hot Water/Steam Heating 0F. AirOne Row Two Row Heating 60F. AirSize Air Sq. Ft Two Row One RowType a and Type 5, hot gas reclaim, heating capacities Temperature DifferenceCoil Perfromance- Heat Reclaim MBH/SQ FT Actual capacity will vary With coil circuiting Refrigerant Evaporating Temperature FCoil Performance- Direct Expansion MBH/SQ FT 400 450 500 550 600Rows Coil Perfromance- Chilled Water MBH/SQ FTChilled FPM, Type a Coils 1/2 DIA FPM, Type 5 Coils 5/8 DIA500 600 650 700 400 Coil Performance- Heating, Water & SteamFPM, Type 5 Coils 5/8 DIA Rows FPM, Type 8 Coils 1 DIA RowsFan Performance SizeCoil Total Size 14 and Size RPM BHPSize 20 and Size 32 3/8 Airfoil Fan Size 65 and Size High Efficiency Filter Sections- DimensionsDimensions inches High Efficiency Filter SectionMixbox Inlet Duct Connections Accessory Flange PatternDimensions Size Sizes 03 Sizes 20Mix box DimensionsReference Motor and coil connectionSizes 03 41 FC DischargeSizes 50 75 AF 12 5/8 Rows 15 5/8 For All Units Sizes10 1/8 MixboxSizes 50 65 AF Depth is dimensionDimension ‘T’ ‘D’ added toSize Edge Sizes 03 Mounting Locations For Vibration IsolatorsFor All Unit Sizes One and two row heating coils do not have For All Unit SizesAll mounting holes are 5/8 inch diameter Rows Inch filters Models Coil SectionVibration Isolators, Quantity Required Air Flow Reheat Position Preheat PositionTo estimate weights for other coils Net Weights and Metal GaugesWeight in pounds Air Handler Component Unit SizeFace Areas- Air Pressure Drops, Dry Coils Face Area Air Handler Unit Size Square FeetFin Air Velocity Feet Per minute Air Pressure Drops- Cabinets, Filters, Wet CoilsDepth Flat & hi 35% Efficient , Pleated Physical Data 19.25 25.50 34.00 40.38 49.50 64.58 74.91 Small Unit SizeCFM Range Cooling 16.04 21.25 27.63 31.88 40.50 51.67 59.42Mechanical Specification