Physical Data

 

 

 

 

 

Unit Size

 

 

 

Description

 

20

26

34

41

50

65

75

CFM Range*

 

 

 

 

 

 

 

 

Cooling

 

6400-10600

8500-14000

10600-18500

13400-22200

17100-26800

22400-35500

25800-41200

Heating & Ventilating

6400-19000

8500-19000

10600-24000

13400-32000

17100-31000

22400-43000

25800-43000

Fan Type & Shaft Diameter @ Bearing

 

 

 

 

 

 

FC, Low Pres.

inches

FC, Med. Pres.

inches

1 7/16—PB

1 7/16—PB

1 11/16—PB

1 15/16—PB

AF, shaft dia. (in) @ bearing

1 7/16—PB

1 7/16—PB

1 11/16—PB

2 3/16—PB

2 7/16—PB

2 11/16—PB

2 11/16—PB

 

 

 

 

 

 

 

 

 

Type 5 Coils

 

 

 

 

 

 

 

 

Large

FH X FL

36.00X77

36.00X102

48.00X102

57.00X102

66.00X108

75.00X124

87.00X124

Refrigerant

TH

24T

24T

32T

38T

44T

50T

58T

and Water Coils

FACE AREA

19.25

25.50

34.00

40.38

49.50

64.58

74.91

Small

FH X FL

30.00X77

30.00X102

39.00X102

45.00X102

54.00X108

60.00X124

69.00X124

Refrigerant

TH

20T

20T

26T

30T

36T

40T

46T

and Water Coils

FACE AREA

16.04

21.25

27.63

31.88

40.50

51.67

59.42

Large Type 5

FH X FL

36X77

36X102

48X102

57.0X102

63.0X108

72.0X124^

84.0X124^

Steam Coils^

TH

24T

24T

32T

38T

42T

24T

28T

 

FACE AREA

19.25

25.50

34.00

40.38

47.25

62.00

72.33

Small Type 5

FH X FL

28.5X77

28.5X102

37.5X102

43.5X102

51X108

60X124^

66X124^

Steam Coils^

TH

19T

19T

25T

29T

34T

20T

22T

 

FACE AREA

12.84

20.19

26.56

30.81

38.25

51.67

56.83

Type A Coils

 

 

 

 

 

 

 

 

Large

FH X FL

37.50X77

37.50X102

47.50X102

57.50X102

67.5X108

75X124

87.5X124

Refrigerant

TH

30T

30T

38T

46T

54T

60T

70T

and Water Coils

FACE AREA

20.05

26.56

33.65

40.73

50.63

64.58

75.35

Small

FH X FL

30X77

30X102

37.5X102

45X102

55X108

60X124

70X124

Refrigerant

TH

24T

24T

30T

36T

44T

48T

56T

and Water Coils

FACE AREA

16.04

21.25

26.56

31.89

41.25

51.67

60.23

Filters:

 

 

 

 

 

 

 

 

 

Area in Sq. Ft.

24.44

31.11

38.89

46.67

54.40

73.33

82.50

Flat

 

 

 

 

 

 

4-16 X 20

 

Section

 

 

 

 

 

 

 

4-16 X 25

 

Quantity and

6-16 X 20

4-16 X 20

4-16 X 25

6-16 x 20

7-16 X 20

8-16 x 20

10-20 X 20

 

size

4-20 X 20

8-20 X 20

8-20 X 25

12-20 x 20

14-16 X 25

20-20 x 20

10-20 X 25

High

Area in Sq. Ft.

31.94

40.28

64.44

80.56

104.17

137.50

160.42

Capacity

 

 

 

 

 

 

 

 

Section

Quantity and

4-16 X 25

10-20 X 25

4-16 X 20

4-16 X 25

30-20 X 25

12-16 X 25

14-16 X 25

 

size

6-20 X 25

2-16 X 25

20-20 X 20

20-20 X 25

 

30-20 X 25

35-20 X 25

High

Area in Sq. Ft.

24.00

30.00

40.00

50.00

60.00

66.00

88.00

Efficiency

 

 

 

 

 

 

 

 

Filter

Quantity and

4-24 X 24

5-24 X 24

10-24 X 24

10-24 X 24

15-24 X 24

15-24 X 24

20-24 X 24

Section

size

4-12 X 24

5-12 X 24

 

5-12 X 24

 

3-12 X 24

4-12 X 24

 

 

 

 

 

 

 

 

 

^The steam coils in models 65 and 75 are not type 5. They are type 8 coils with 1" diameter tubes on 3" centers. * The CFM range for cooling and heating starts at a low of about 400 fpm through small coil.

The maximum CFM for cooling is at no more than 550 fpm through a large coil. The maximum CFM for heating is at no more than 900 fpm through a large coil. The fan tables are on pages 24 through 29.

Fan Type

Bearings

Coils

Filters

 

FC = Forward curve fan

(Ball Type)

FH X FL

1-24 X 24

Means one 24" by 24 “ filter

AF = Airfoil fan

C = Cartridge

FH = Finned Height , inches

 

 

Shaft Diameter is inches

PB = Pillow Block

FL = Finned Length, inches

 

 

 

 

TH = Tubes High

 

 

 

 

FACE AREA is in Square Feet.

 

 

 

 

Refrigerant can be either direct

expansion, heat

reclaim , or condenser coil.

43

Image 43
Contents Air Handlers Quality Standard IndexCabinet style Fan Type NomenclatureStandard Unit Features Heat Reclaim Coils Air Handler CoilsDirect Expansion Coils Water CoilsConstruction & Dimensions Accessories- Electric HeatUnit Heater Dimensions Size Maximum KW Electric Heater Selection ExampleComponent 208 240 460 480 Accessories Filters And Auxiliary Sections Auxilary Sections- All unit Sizes Dimensions, Page 29 to‘A’ = Available Accessories for Fan and Coil SectionsAvailable Motors, Drives, Motor Starters per Horsepower Motor Drive Starter Motor Horsepower DescriptionSelection Conditions Air Handler SelectionSelection Example Selection ProcedureCu m/h Air volume at Air handler DX air Refrigerant Chilled waterAir Handler Performance Quick Reference SteamCoil Air Handler Performance- Direct Expansion1553 Saturated Suction TemperatureAir Handler Perfromance- Direct Expansion 1339Row Coils Air Handler Performance- Chilled WaterSize Air Area Std Face Air Handler Perfromance- Chilled WaterHeating 0F. Air Air Handler Performance- Hot Water/SteamTwo Row One Row Heating 60F. AirSize Air Sq. Ft One Row Two RowCoil Perfromance- Heat Reclaim MBH/SQ FT Temperature DifferenceType a and Type 5, hot gas reclaim, heating capacities 400 450 500 550 600 Refrigerant Evaporating Temperature FCoil Performance- Direct Expansion MBH/SQ FT Actual capacity will vary With coil circuitingFPM, Type a Coils 1/2 DIA FPM, Type 5 Coils 5/8 DIA Coil Perfromance- Chilled Water MBH/SQ FTChilled RowsFPM, Type 8 Coils 1 DIA Rows Coil Performance- Heating, Water & SteamFPM, Type 5 Coils 5/8 DIA Rows 500 600 650 700 400Size Fan PerformanceCoil Total RPM BHP Size 14 and SizeSize 20 and Size 32 3/8 Airfoil Fan High Efficiency Filter Section High Efficiency Filter Sections- DimensionsDimensions inches Size 65 and SizeSizes 03 Sizes 20 Accessory Flange PatternDimensions Size Mixbox Inlet Duct ConnectionsMotor and coil connection DimensionsReference Mix boxDischarge Sizes 03 41 FCSizes 50 75 AF Mixbox For All Units Sizes10 1/8 12 5/8 Rows 15 5/8‘D’ added to Depth is dimensionDimension ‘T’ Sizes 50 65 AFFor All Unit Sizes Sizes 03 Mounting Locations For Vibration IsolatorsSize Edge All mounting holes are 5/8 inch diameter Rows Inch filters For All Unit SizesOne and two row heating coils do not have Air Flow Reheat Position Preheat Position Coil SectionVibration Isolators, Quantity Required ModelsAir Handler Component Unit Size Net Weights and Metal GaugesWeight in pounds To estimate weights for other coilsFace Area Air Handler Unit Size Square Feet Face Areas- Air Pressure Drops, Dry CoilsDepth Flat & hi 35% Efficient , Pleated Air Pressure Drops- Cabinets, Filters, Wet CoilsFin Air Velocity Feet Per minute Physical Data 16.04 21.25 27.63 31.88 40.50 51.67 59.42 Unit SizeCFM Range Cooling 19.25 25.50 34.00 40.38 49.50 64.58 74.91 SmallMechanical Specification