8 | GAS INSTRUCTIONS |
|
|
Check:
1)Corrugated gas
2)Main gas Supply to regulator
WARNING: If there is a leak a connection(1), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact informa- tion sheet provided with your manual.
Check:
When leak checks are complete, turn gas supply OFF at the source and rinse connec- tions with water.
SIDE BURNER LIGHTING INSTRUCTIONS
DANGER
Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive
LIGHTING THE SIDE BURNER
1)Open the side burner lid.
2)Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure it is in the off position.).
3)Turn the gas supply valve on.
4)Push down and turn the side burner control valve to START/HI.
5)Push igniter button and hold until burner ignites. You will hear the igniter sparking.
a
b
c
(1) a.
(2)
b.
c.
NG CONNECTION TEST
Top View
To SIde Burner
To Regulator
CAUTION: Side burner flame may be difficult to see on a bright sunny day.
WARNING: If the side burner does not light:
1)Turn OFF the side burner control valve.
2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.
WWW.WEBER.COM®