Summit 89795 Operating / Maintenance, Manually Lighting the Side Burner, Igniter, To Extinguish

Page 9

OPERATING / MAINTENANCE

9

 

 

MANUALLY LIGHTING THE SIDE BURNER

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

1)Open the side burner lid.

2)Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure that it is in the off position.).

3)Turn the gas supply valve on.

4)Put match in a match holder and strike match.

5)Push down and turn the side burner control valve to START/HI.

6)Hold match holder and lit match by right side of side burner.

IGNITER

If the Ignition system fails to ignite the side burner, light the burner with a match.

Check that both ignition wires(1,2) are attached properly.

You should hear the igniter sparking.

If the ignition system still fails to light, contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

REPLACE IGNITER BATTERIES

Parts required: 1 AA alkaline battery per igniter.

Unscrew igniter button from front of control panel. Remove igniter button and contact spring. Remove old battery and replace with a new AA

alkaline battery. Positive end (1) of battery faces inward as shown in illustration. Re- place spring contact (2) and screw igniter button (3) back onto battery compartment.



 





7)Push igniter button and hold until burner ignites. You will hear the igniter sparking.

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light:

1)Turn OFF the side burner control valve.

2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.

TO EXTINGUISH

Push down and turn each burner control knob clockwise to the OFF position. Turn gas supply OFF at the source.

WWW.WEBER.COM®

Image 9
Contents #89795 Liquid Propane GAS Units only Warranty WARRANTY3Operating GAS Supply Testing StorageSide Burner Location GAS InstructionsSide Burner Locating Your BUILT-IN Side BurnerGAS Line Locations GAS InstructionsBUILT-IN GAS Line Locations General Construction Details Test ConnectionsTypical Natural GAS Supply Installation General Specifications for PipingGAS Line Piping Connect GAS Supply Test ConnectionsNG Connection Test Side Burner Lighting InstructionsLighting the Side Burner Manually Lighting the Side Burner Operating / MaintenanceIgniter Replace Igniter BatteriesSide Burner Troubleshooting Problem Check CureSide Burner Maintenance Antes DE Poner a Funcionar LA Barbacoadegas Peligro Peligros Y AdvertenciasGarantía GARANTÍA13Almacenaje OperaciónUbicación DEL Quemador Lateral Instrucciones Para EL GASQuemador Lateral Ubicación DEL Quemador Lateral EmpotradoUbicaciones DE LA Línea DE GAS Instrucciones Para EL GASPruebe LAS Conexiones Montaje DEL Quemador LateralInstalación Típica Para EL Suministro DE GAS Natural Especificaciones Generales Para LA TuberíaTubería DE LA Línea DE GAS Conexiones DE Suministro DE GAS Natural AL Quemador Lateral Pruebe LAS ConexionesConectar EL Suministro DE GAS Encendido DEL Quemador Lateral Instrucciones Para Encender EL Quemador LateralEncendido Manual DEL Quemador Lateral Operación /MANTENIMIENTOEncendedor Reemplace LAS Baterías DEL EncendedorResolución DE Problemas CON EL Quemador Lateral Problema Revisar RemedioMantenimiento DEL Quemador Lateral Mise EN Garde Mises EN Garde Garantie GARANTIE23Stockage UtilisationLocalisation DU Bruleur Lateral Instructions Relatives AU GAZBruleur Lateral Localisation DE Votre Bruleur Lateral EncastreLocalisations DES Conduites DE GAZ Instructions Relatives AU GAZTest DES Connexions Montage DU Bruleur LateralInstallation D’ARRIVEE DE GAZ Naturel Typique Generalites Concernant LES CanalisationsCanalisations DE GAZ Test DES Raccords Test DES RaccordsRaccordement DE L’ARRIVEE DE GAZ Raccords D’ARRIVEE DE GAZ Naturel DU Bruleur LateralAllumage DU Bruleur Lateral Instructions Pour L’ALLUMAGE DU Bruleur LateralAllumage Manuel DU Bruleur Lateral UTILISATION/MAINTENANCE29Pour Eteindre AllumeurProbleme Verification Solution Maintenance DU Bruleur LateralDepannage DU Bruleur Lateral Page WEBER-STEPHEN Products CO