IDEAL INDUSTRIES HE24 General, Boiler Data Boiler Size HE 12, HE 15, HE 18, HE, Key to symbols

Page 4

GENERAL

Table 1 - Boiler Data

Boiler Size

 

 

 

 

 

 

HE 12, HE 15, HE 18, HE 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas supply type and connection

 

 

 

 

2H-G20-20 mbar Rc1/2

(1/2" BSP Female)

 

Injector size

 

 

 

 

 

Stereomatic 5.6mm dia. (HE 12 5.8mm dia).

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow connection

 

 

 

 

 

 

 

22mm copper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return connection

 

 

 

 

 

 

 

22mm copper

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue terminal diameter

mm (in.)

 

 

 

100 (4)

 

 

Maximum static water head

m (ft.)

 

 

 

30.5 (100)

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum static water head

m (ft.)

 

 

 

0.45 (1.5)

 

 

Electrical supply

 

 

 

 

 

 

 

230 V ~ 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler power consumption

 

 

 

 

 

38W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse rating

 

 

 

 

 

 

External: 3A Internal: T3.15A L250 V

 

Water content

 

 

litre (gal.)

 

 

 

1.7 (0.37)

 

 

 

 

 

 

 

 

 

 

 

 

 

Packaged weight

 

 

kg (lb.)

 

 

 

38 (84)

 

 

 

 

 

 

 

 

 

 

 

 

Maximum installation weight

kg (lb.)

 

 

 

31 (68)

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler size

 

Height

mm (in.)

 

 

 

582 (23)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

mm (in.)

 

 

 

390 (15)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

mm (in.)

 

 

 

278 (11)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2 - Performance Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler Size

 

 

 

 

 

HE 12 Max

HE 15 Max

HE 18 Max

HE 24 Max

HE 12 Min

HE 15-24 Min

 

 

 

 

 

 

 

 

 

 

 

 

Boiler input 'Q' =

Nett CV

 

 

kW

12.2

15.1

18.7

 

24.4

9.8

9.1

 

 

 

 

 

Btu/h

41 600

51 500

63 800

 

83 300

33 400

31 000

 

 

 

 

 

 

 

 

 

 

 

 

 

Gross CV

 

 

kW

13.5

16.8

20.7

 

27.1

10.9

10.1

 

 

 

 

 

Btu/h

46 000

57 200

70 800

 

92 500

37 200

34 400

 

 

 

 

 

 

 

 

 

 

Gas consumption

l/s (cu.ft/h)

0.35 (44.2)

0.43 (54.7)

0.53 (68.0)

0.70 (89.7)

0.28 (35.6)

0.26 (33.3)

 

 

 

 

 

 

 

 

 

 

 

Boiler output 'P' =

70 oC Mean water

 

kW

12.0

14.6

18.2

 

23.4

9.3

8.8

 

temperature

 

 

Btu/h

40 900

50 000

62 300

 

80,000

31 800

30,000

 

 

 

 

 

 

 

 

 

 

 

 

40 oC Mean water

 

kW

12.7

15.5

19.2

 

25.1

10.5

9.6

 

temperature

 

 

Btu/h

43 300

53 000

65 700

 

85 700

35 900

32 800

Seasonal efficiency (SEDBUK) *

 

 

Band A

[90.1]%

[90.4]%

[90.3]%

 

[90.2]%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOx classification

 

 

 

 

 

 

 

Class 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from which it has been calculated have been certified by a notified body.

Note.

Gas consumption is calculated using a calorific value of

38.7MJ/m3 (1038 Btu/ft3) gross or 34.9 MJ/m3 (935 Btu/ft3) nett. To obtain the gas consumption at a different calorific value:-

a.For l/s - divide the gross heat input (kW) by the gross C.V. of the gas (MJ/m3)

b.For ft3/h - divide the gross heat input (Btu/h) by the gross C.V. of the gas (Btu/ft3)

Key to symbols

GB = United Kingdom IE = Ireland (Countries of destination) PMS = Maximum operating pressure of water

C13 C33 C53 = A room sealed appliance designed for connection via

 

ducts to a horizontal or vertical terminal which admits

 

fresh air to the burner and discharges the products of

 

combustion to the outside through orifices which, in this

 

case, are concentric. The fan is up stream of the

 

combustion chamber.

I2H

= An appliance designed for use on 2nd Family gas, Group

 

H only.

CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of this appliance, care should be taken when handling edges of sheet steel components.

4

icos - Installation & Servicing

Image 4
Contents Installation and servicing Icos Installation & Servicing 15, Frame 12 Packaging Removal 15, Frame 11 Unpacking17, Frame 16 Wall Mounting Template General Key to symbolsBoiler Data Boiler Size HE 12, HE 15, HE 18, HE Icos Rear Flue only General Boiler Water ConnectionsSide Flue only Safety General IntroductionOperation Safe HandlingFlue Installation General Safe Handling of SubstancesLocation of Boiler GAS SupplyTerminal AIR SupplyWater Circulation System Boiler Control InterlocksGeneral Open Vent System Requirements Schematic Pipework and System BalancingBalancing Safety Valve Sealed System RequirementsGeneral Pressure GaugeSealed System Requirements Water Treatment Icos boiler range have an Aluminium alloy heat exchangerInstallation Boiler Assembly Exploded viewInstallation Unpacking Unpack and check the contents Pack a ContentsPack Contents Packaging RemovalDetermining the Flue Length and Flue Packs Required Installation Front and Bottom Panel RemovalFlue Kits Flue Assembly Exploded View Wall Mounting TemplateInstallation Preparing the Wall Setting the Flue RearSetting the Flue Side Wall thicknesses of 210 to 435mmPack D Flue extension duct kit contents Flue Extension DuctsFitting the KIT General arrangementCondensate Pipe Termination Configurations Installation Condensate DrainFront View Condensate Pipe Termination Configurations Connecting the Flue to the Boiler Installation Mounting the BoilerFlues over 1 metre long Roof Flue KIT Contents / Options Flue OutletTerminal Position Minimum Dimension Installation Flue Terminal PositionFlat roof with structure Installation Flue Arrangement Installation Assembling the Roof Flue KIT Gaskets in the Boiler Flue Outletare Correctly FittedInstallation GAS Connection Electrical ConnectionsInstallation Internal Wiring Incoming mains wiring detailMains Connector Socket Supplied in hardware pack Fixed to boilerInstallation Pictorial Wiring Diagram Functional Flow Wiring DiagramInstallation External Electrical Controls Commissioning and TestingElectrical Installation GAS Installation Room ThermostatInstallation Initial Lighting FasciaInstallation General Checks Water Circulation System Knob Setting Flow TemperatureHanding Over Central HeatingBoiler Front Panel Removal Servicing Servicing ScheduleBoiler Sealing PANEL/ Bottom Panel Removal Servicing FAN and Venturi Assembly Removal and Cleaning Burner Removal and CleaningServicing Cleaning the Condensate S Trap Cleaning the Heat ExchangerReassembly Reassemble the boiler in the following orderWhen replacing ANY component Servicing Replacement of ComponentsGeneral Servicing FAN Replacement Burner ReplacementRefer to Frame Remove the boiler front and sealingServicing Ignition Electrode Replacement Flame Detection Electrode ReplacementBurner Injector Replacement Servicing Spark Generator ReplacementGAS Control Valve Replacement Mains Switch Replacement Servicing Control BOX ReplacementTo change the user control only Servicing Overheat Thermostat Replacement Flue Thermistor ReplacementServicing Combustion Chamber Insulation Replacement Servicing Heat Exchanger Replacement Servicing Boiler Sealing Panel Seal Replacement Condensate S Trap ReplacementAlternating H n Fault Finding Fault Finding Chart Main MenuAlternating H E GO to Frame Alternating H9 Alternating L9 Fault Finding Flame ErrorBoard Error 70 L.....FOverheat Error 73 L....8..... FAN ErrorFlow Thermistor Error 72 L.......AFlame Detection Short Circuit Error 76 H.....4...... Flue Thermistor ErrorPhase Reversal Error 75 H......FShort List of Parts GC Part No Description Qty Product NoBoiler Casing Assembly List of Parts Controls Assembly Burner AssemblyIcos Installation & Servicing Installer Notification Guidelines Page Page Technical Training Certified ProductUsers guide To light the boiler Refer to Frame Minimum ClearancesOperation For short periods Knob Setting Flow Temperature Minimum Maximum 180For longer periods Problem Solution Points for the Boiler User
Related manuals
Manual 52 pages 43.45 Kb

HE12, HE15, HE18, HE24 specifications

The IDEAL INDUSTRIES HE series, comprising the HE24, HE18, HE15, and HE12 models, represents a significant advancement in the field of electrical testing and measurement tools. These versatile testers stand out in professional environments for their high accuracy, user-friendly interfaces, and advanced features designed to enhance efficiency and reliability in electrical inspections.

The HE24 is the flagship model, boasting an extensive range of functionalities. It includes advanced digital multimeter capabilities, allowing for precise measurements of voltage, current, and resistance. Its True RMS feature ensures accurate readings, even with non-linear loads. The HE24 also incorporates advanced connectivity options, including Bluetooth technology, enabling users to transfer data wirelessly to smartphones or tablets for further analysis. The large, backlit display enhances visibility in various lighting conditions, making it an ideal tool for both indoor and outdoor use.

The HE18 model, while slightly more streamlined than the HE24, still offers robust capabilities. It features multiple testing modes, including continuity and diode testing, catering to a wide range of electrical tasks. The HE18 also utilizes a user-friendly interface, allowing technicians to navigate easily through various functions. Equipped with a protective rubber housing, this model is durable and built to withstand the rigors of frequent use on job sites.

The HE15 and HE12 models represent the compact, entry-level offerings in the HE series. Designed for the budget-conscious user, these models retain essential functionalities such as basic voltage and current measuring capabilities while prioritizing ease of use. The HE15 includes a simple LED indicator to signal when measurements are being taken, promoting straightforward operation. Additionally, the HE12 features a lightweight design, making it the perfect tool for on-the-go technicians.

All models in the IDEAL INDUSTRIES HE series are engineered with safety in mind, adhering to stringent international testing standards. They provide superior insulation resistance and a high degree of accuracy, mitigating the risks associated with electrical work. Furthermore, their IP-rated enclosures ensure protection against dust and moisture, enhancing longevity.

In conclusion, the IDEAL INDUSTRIES HE24, HE18, HE15, and HE12 series represent a comprehensive range of electrical testing tools that cater to professionals' varied needs. With their combination of advanced features, user-friendly designs, and safety compliance, these models are excellent choices for any electrical technician aiming for accuracy and efficiency in their work.