Burnham Series 2B manual Base Assembly

Page 32

Base Assembly

Key

Description

Boiler

Part No.

Qty.

No.

Size

3. Base Assembly

 

 

 

 

 

202

618600291

1

 

 

 

 

 

 

 

202X

618600391

1

 

 

 

 

 

 

 

203

618600391

1

 

 

 

 

 

 

Base Assembly

204

618600491

1

 

 

 

 

 

205

618600591

1

3

(Complete)

 

 

 

Available for 1 Inch

206

618600691

1

 

 

Burners Only

 

 

 

 

 

207

618600791

1

 

 

 

 

 

 

 

 

 

208

618600891

1

 

 

 

 

 

 

 

209

618600991

1

 

 

 

 

 

 

 

210

618601091

1

 

 

 

 

 

 

 

202

718600291

1

 

 

 

 

 

 

 

202X

718600391

1

 

 

 

 

 

 

 

203

718600391

1

 

 

 

 

 

 

 

204

718600491

1

 

 

 

 

 

3A

Base Tray

205

718600591

1

 

 

 

206

718600691

1

 

 

 

 

 

 

 

 

 

207

718600791

1

 

 

 

 

 

 

 

208

718600891

1

 

 

 

 

 

 

 

209

718600991

1

 

 

 

 

 

 

 

210

718601091

1

 

 

 

 

 

32

Key

Description

Boiler

Part No.

Qty.

No.

Size

3. Base Assembly Continued

 

 

 

 

202

718600211

1

 

 

 

 

 

 

 

202X

718600311

1

 

 

 

 

 

 

 

203

718600311

1

 

 

 

 

 

 

 

204

718600411

1

 

 

 

 

 

3B

Base Wrapper

205

718600511

1

 

 

 

206

718600611

1

 

 

 

 

 

 

 

 

 

207

718600711

1

 

 

 

 

 

 

 

208

718600811

1

 

 

 

 

 

 

 

209

718600911

1

 

 

 

 

 

 

 

210

718601011

1

 

 

 

 

 

3B1

Base End Insulation

All

720601

2

 

 

 

 

 

 

 

202

72060025

1

 

 

 

 

 

 

 

202X

72060035

1

 

 

 

 

 

 

 

203

72060035

1

 

 

 

 

 

 

 

204

72060045

1

 

 

 

 

 

3B2

Base Rear Insulation

205

72060055

1

 

 

 

206

72060065

1

 

 

 

 

 

 

 

 

 

207

72060075

1

 

 

 

 

 

 

 

208

72060085

1

 

 

 

 

 

 

 

209

72060095

1

 

 

 

 

 

 

 

210

72060105

1

 

 

 

 

 

Image 32
Contents Series 2 model B Price $3.00Table of Contents Weight Do not drop boiler. Do not bump boiler jacket against floor ClearancesMinimum Clearances Boiler Piping Equivalent Length of FittingsSpecific Gravity Correction Factors for Natural Gas Page Page Do not use one vent damper to control two heating appliances Page Wiring Diagrams and Heat Anticipator Settings Page Safety Shutdown Sequence of Operation Page Sequence of Operation Normal Operation Wiring Schematic, Zone Valves II. Operating Instructions Top View of VR Gas Valves Instructions to PUT the Boiler in Operation Yellow LED Flame CodesGreen LED Status Codes Lighting Instructions Check GAS Input Rate to Boiler Check Pilot Burner FlameCheck Ignition System Safety SHUT-OFF Device Combustion Chamber BURN-OFFIII. Trouble Shooting IV. Service Burner 40mm Burner Pilot Burner LocationAvoid Breathing Fiber Particulates and Dust Repair Parts Section Assembly Gravity Circulation OnlySection Assembly and Canopy Group Canopy GroupThis page Left Intentionally Blank Base Assembly USS Manifold and Main Burners Inch Main Burners Manifold and Main Burners 1 Inch Main Burners Only 4B MM Main Burner, Electronic Ignition Only Manifold and Main Burners 40mm Main BurnersMM Main Burners Only MM Main Burners Only 4C MM Main Burner Manifold 4D MM Main Burner, Natural Gas, 2001-5000 Ft. USA Only4D MM Main Burner, LP Gas, 2001-5000 Ft. USA Only 4D MM Main Burner, Natural Gas, 5001-9000 Ft. USA OnlyBurner Only 40mm Burner Only Pilot Burner, Honeywell Q327A1147 Pilot Burner, Honeywell Q348A1002 Jacket Assembly, Complete Jacket AssemblyPage Jacket Vestibule Panel Water Trim Limit Control Transformer/Relay Assembly Intermittent Circulation Only Flame Rollout SwitchBlocked Vent Switch Transformer Continuous and Gravity Circulation OnlyVent Reducer Draft Hood CartonVent Damper Service Record Service Record Service Record Wiring of Typical Lwco Lwco LocationLimited Warranty