Burnham Series 2B manual Pilot Burner, Honeywell Q348A1002

Page 40

Key

Description

Part No.

 

 

 

 

Quantity

 

 

 

 

No.

202

202X

203

204

205

206

207

208

209

210

5. Pilot Burner and Gas Valve, Electronic Ignition (EI), Natural Gas

 

 

 

 

 

 

 

 

5A

Pilot Burner, Honeywell Q348A1002

8236072

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

5B

Pilot Orifice, Honeywell 388146NE

Included

1

1

1

1

1

1

1

1

1

1

with 5A

 

 

 

 

 

 

 

 

 

 

 

 

5C

Compression Nut/Fitting, 1/4" OD x 1/4 C.C.

8236109

2

2

2

2

2

2

2

2

2

2

(Included with 5A and 5E)

 

 

 

 

 

 

 

 

 

 

 

 

5D

Pilot Tubing, 1/4" OD x 30"

8236122

1

1

1

1

1

1

1

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Tubing, 1/4" OD x 40"

8236123

---

---

---

---

---

---

---

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5E

Gas Valve, Honeywell VR8204C3007

81660145

1

1

1

1

1

1

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve, Honeywell VR8304P4306

81660161

---

---

---

---

---

---

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5F

Igniter/Sensor Cable, 36", Honeywell 394800

8236084

1

1

1

1

1

1

1

1

1

1

5G

Ground Wire Assembly

6136054

1

1

1

1

1

1

1

1

1

1

5. Pilot Burner and Gas Valve, Electronic Ignition (EI), LP/Propane

 

 

 

 

 

 

 

 

5A

Pilot Burner, Honeywell Q348A1010

8236081

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

5B

Pilot Orifice, Honeywell 388146KP

Included

1

1

1

1

1

1

1

1

1

1

with 5A

 

 

 

 

 

 

 

 

 

 

 

 

5C

Compression Nut/Fitting, 1/4" OD x 1/4 C.C.

8236109

2

2

2

2

2

2

2

2

2

2

(Included with 5A and 5E)

 

 

 

 

 

 

 

 

 

 

 

 

5D

Pilot Tubing, 1/4" OD x 30"

8236122

1

1

1

1

1

1

1

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Tubing, 1/4" OD x 40"

8236123

---

---

---

---

---

---

---

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5E

Gas Valve, Honeywell VR8204C3015

81660146

1

1

1

1

1

1

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve, Honeywell VR8304P4314

81660160

---

---

---

---

---

---

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5F

Igniter/Sensor Cable, 36", Honeywell 394800

8236084

1

1

1

1

1

1

1

1

1

1

5G

Ground Wire Assembly

6136054

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

40

Image 40
Contents Series 2 model B Price $3.00Table of Contents Weight Do not drop boiler. Do not bump boiler jacket against floor ClearancesMinimum Clearances Specific Gravity Correction Factors for Natural Gas Equivalent Length of FittingsBoiler Piping Page Page Do not use one vent damper to control two heating appliances Page Wiring Diagrams and Heat Anticipator Settings Page Safety Shutdown Sequence of Operation Page Sequence of Operation Normal Operation Wiring Schematic, Zone Valves II. Operating Instructions Top View of VR Gas Valves Instructions to PUT the Boiler in Operation Yellow LED Flame CodesGreen LED Status Codes Lighting Instructions Check GAS Input Rate to Boiler Check Pilot Burner FlameCheck Ignition System Safety SHUT-OFF Device Combustion Chamber BURN-OFFIII. Trouble Shooting IV. Service Burner 40mm Burner Pilot Burner LocationAvoid Breathing Fiber Particulates and Dust Repair Parts Section Assembly Gravity Circulation OnlySection Assembly and Canopy Group Canopy GroupThis page Left Intentionally Blank Base Assembly USS Manifold and Main Burners Inch Main Burners Manifold and Main Burners 1 Inch Main Burners Only MM Main Burners Only Manifold and Main Burners 40mm Main Burners4B MM Main Burner, Electronic Ignition Only MM Main Burners Only 4C MM Main Burner Manifold 4D MM Main Burner, Natural Gas, 2001-5000 Ft. USA Only4D MM Main Burner, LP Gas, 2001-5000 Ft. USA Only 4D MM Main Burner, Natural Gas, 5001-9000 Ft. USA OnlyBurner Only 40mm Burner Only Pilot Burner, Honeywell Q327A1147 Pilot Burner, Honeywell Q348A1002 Jacket Assembly, Complete Jacket AssemblyPage Jacket Vestibule Panel Water Trim Limit Control Transformer/Relay Assembly Intermittent Circulation Only Flame Rollout SwitchBlocked Vent Switch Transformer Continuous and Gravity Circulation OnlyVent Damper Draft Hood CartonVent Reducer Service Record Service Record Service Record Wiring of Typical Lwco Lwco LocationLimited Warranty