Burnham Series 2B manual Uss

Page 33

Key

Description

Boiler

Part No.

Qty.

No.

Size

 

 

 

 

 

3. Base Assembly Continued

 

 

 

 

202

618600241

1

 

 

 

 

 

 

 

202X

618600341

1

 

 

 

 

 

 

 

203

618600341

1

 

 

 

 

 

 

 

204

618600441

1

 

 

 

 

 

3C

Base Front Panel

205

618600541

1

 

 

 

Assembly

206

618600641

1

 

 

 

 

 

 

 

 

 

 

207

618600741

1

 

 

 

 

 

 

 

208

618600841

1

 

 

 

 

 

 

 

209

618600941

1

 

 

 

 

 

 

 

210

618601041

1

 

 

 

 

 

 

 

202

718600205

1

 

 

 

 

 

 

 

202X

718600305

1

 

 

 

 

 

 

 

203

718600305

1

 

 

 

 

 

 

 

204

718600405

1

 

 

 

 

 

 

Burner Tray (1" Main

205

718600505

1

 

 

 

 

 

Burners)

206

718600605

1

 

 

 

 

 

 

 

 

 

207

718600705

1

 

 

 

 

 

 

 

208

718600805

1

 

 

 

 

 

 

 

209

718600905

1

 

 

 

 

 

3D

 

210

718601005

1

 

 

 

 

 

202

718600206

1

 

 

 

 

 

 

 

 

 

202X

71806037

1

 

 

 

 

 

 

 

203

71806037

1

 

 

 

 

 

 

 

204

71806047

1

 

 

 

 

 

 

Burner Tray

205

71806057

1

 

(40mm Main Burners)

206

71806067

1

 

 

 

 

 

 

 

 

 

207

71806077

1

 

 

 

 

 

 

 

208

718600806

1

 

 

 

 

 

 

 

209

718600906

1

 

 

 

 

 

 

 

210

718601006

1

 

 

 

 

 

Key

Description

Boiler

Part No.

Qty.

No.

Size

 

 

 

 

 

3. Base Assembly Continued

 

 

3E

Base Leg Assembly

All

6186001

4

3E1

Base Leg

All

71860021

4

3E2

Nylon Glide

All

8186006

4

 

 

 

 

 

 

 

202

718600261

1

 

 

 

 

 

 

 

202X

718600361

1

 

 

 

 

 

 

 

203

718600361

1

 

 

 

 

 

 

 

204

718600461

1

 

 

 

 

 

3F

Burner Access Panel

205

718600561

1

 

 

 

206

718600661

1

 

 

 

 

 

 

 

 

 

207

718600761

1

 

 

 

 

 

 

 

208

718600861

1

 

 

 

 

 

 

 

209

718600961

1

 

 

 

 

 

 

 

210

718601061

1

 

 

 

 

 

 

Cerafelt Sealing Strip,

 

 

 

3G

1" x 2" x 10' (Section

All

6206002

1

 

Assembly to Base)

 

 

 

 

 

 

 

 

 

 

202

 

 

 

 

thru

80860700

20

3H

Self-Tapping Screw,

206

 

 

 

 

 

1/4" -20 x 1/2"

207

 

 

 

 

 

 

 

thru

80860700

21

 

 

210

 

 

 

 

 

 

 

3J

Self-Tapping Screw,

All

80860717

4

5/16" -18 x 1-1/4"

 

 

 

 

 

 

 

 

 

3K

Flat Washer, 5/16",

All

80860601

4

USS

 

 

 

 

3L

Hex Lock Nut,

All

80860464

4

5/16 -18

 

 

 

 

 

 

 

 

 

33

Image 33
Contents Price $3.00 Series 2 model BTable of Contents Weight Clearances Do not drop boiler. Do not bump boiler jacket against floorMinimum Clearances Equivalent Length of Fittings Specific Gravity Correction Factors for Natural GasBoiler Piping Page Page Do not use one vent damper to control two heating appliances Page Wiring Diagrams and Heat Anticipator Settings Page Safety Shutdown Sequence of Operation Page Sequence of Operation Normal Operation Wiring Schematic, Zone Valves II. Operating Instructions Top View of VR Gas Valves Yellow LED Flame Codes Instructions to PUT the Boiler in OperationGreen LED Status Codes Lighting Instructions Check Pilot Burner Flame Check GAS Input Rate to BoilerCombustion Chamber BURN-OFF Check Ignition System Safety SHUT-OFF DeviceIII. Trouble Shooting IV. Service Pilot Burner Location Burner 40mm BurnerAvoid Breathing Fiber Particulates and Dust Section Assembly Gravity Circulation Only Repair PartsCanopy Group Section Assembly and Canopy GroupThis page Left Intentionally Blank Base Assembly USS Manifold and Main Burners Inch Main Burners Manifold and Main Burners 1 Inch Main Burners Only Manifold and Main Burners 40mm Main Burners MM Main Burners Only4B MM Main Burner, Electronic Ignition Only 4D MM Main Burner, Natural Gas, 2001-5000 Ft. USA Only MM Main Burners Only 4C MM Main Burner Manifold4D MM Main Burner, LP Gas, 2001-5000 Ft. USA Only 4D MM Main Burner, Natural Gas, 5001-9000 Ft. USA OnlyBurner Only 40mm Burner Only Pilot Burner, Honeywell Q327A1147 Pilot Burner, Honeywell Q348A1002 Jacket Assembly Jacket Assembly, CompletePage Jacket Vestibule Panel Water Trim Limit Control Flame Rollout Switch Transformer/Relay Assembly Intermittent Circulation OnlyBlocked Vent Switch Transformer Continuous and Gravity Circulation OnlyDraft Hood Carton Vent DamperVent Reducer Service Record Service Record Service Record Lwco Location Wiring of Typical LwcoLimited Warranty