Burnham Series 2B manual MM Main Burners Only 4C MM Main Burner Manifold

Page 37

Key

Description

Part No.

 

 

 

Quantity

 

 

 

 

No.

202X

203

204

205

206

 

207

208

209

210

 

 

 

4. 40 MM Main Burners Only (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4C. 40MM Main Burner Manifold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260028

---

---

---

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260038

1

1

---

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260048

---

---

1

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260058

---

---

---

1

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

4C

Manifold

82260068

---

---

---

---

1

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260078

---

---

---

---

---

 

1

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260088

---

---

---

---

---

 

---

1

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260098

---

---

---

---

---

 

---

---

1

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82260108

---

---

---

---

---

 

---

---

---

1

 

 

 

 

 

 

 

 

 

 

 

 

 

4D. 40 MM Main Burner, Natural Gas, 2001-5000 Ft. USA Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#43

822713

2

---

---

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

4D

#39

822727

---

2

3

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#38

822720

---

---

---

4

5

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

4D. 40 MM Main Burner, LP Gas, 2001-5000 Ft. USA Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4D

#54

822734

2

---

---

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

#53

822722

---

2

3

4

5

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4D. 40 MM Main Burner, Natural Gas, 5001-9000 Ft. USA Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4D

#41

822729

N/A

2

3

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

#40

822728

---

---

---

4

5

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4D. 40 MM Main Burner, LP Gas, 5001-9000 Ft. USA Only

 

 

 

 

 

 

 

 

 

 

4D

#54

822734

N/A

2

---

---

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

#53

822722

---

---

3

4

5

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4D. 40 MM Main Burner, Natural Gas, 2001-4500 Ft. Canada Only

 

 

 

 

 

 

 

 

 

4D

#37

822719

N/A

2

3

4

---

 

---

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

#36

822771

---

---

---

---

5

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4D. 40 MM Main Burner, LP Gas, 2001-4500 Ft. Canada Only

 

 

 

 

 

 

 

 

 

4D

#52

822721

N/A

2

3

4

5

 

6

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw, Machine, Slotted Round Head,

80860800

2

2

2

2

2

 

2

2

2

2

 

#10-32 x 3/16" (Standing Pilot)

 

 

 

 

 

 

 

 

 

 

 

 

 

4E

Screw, Machine, Philips Head

 

 

 

 

 

 

 

 

 

 

 

 

w/Captive Lockwasher, #10-32 x 1/4"

80860874

1

1

1

1

1

 

1

1

1

1

 

(Electronic Ignition)

 

 

 

 

 

 

 

 

 

 

 

4F

Screw, Self Tapping, Philips Pan Head,

80860700

4

4

4

4

4

 

4

4

4

4

1/4 -20 x 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

4G

Injection Shield Assembly

71860_ _62

A/R

A/R

A/R

A/R

A/R

 

A/R

A/R

A/R

A/R

 

 

 

 

 

 

 

 

 

 

 

 

 

_ _: number of cast iron sections

 

 

 

 

 

 

 

 

 

 

 

37

Image 37
Contents Price $3.00 Series 2 model BTable of Contents Weight Clearances Do not drop boiler. Do not bump boiler jacket against floorMinimum Clearances Specific Gravity Correction Factors for Natural Gas Equivalent Length of FittingsBoiler Piping Page Page Do not use one vent damper to control two heating appliances Page Wiring Diagrams and Heat Anticipator Settings Page Safety Shutdown Sequence of Operation Page Sequence of Operation Normal Operation Wiring Schematic, Zone Valves II. Operating Instructions Top View of VR Gas Valves Yellow LED Flame Codes Instructions to PUT the Boiler in OperationGreen LED Status Codes Lighting Instructions Check Pilot Burner Flame Check GAS Input Rate to BoilerCombustion Chamber BURN-OFF Check Ignition System Safety SHUT-OFF DeviceIII. Trouble Shooting IV. Service Pilot Burner Location Burner 40mm BurnerAvoid Breathing Fiber Particulates and Dust Section Assembly Gravity Circulation Only Repair PartsCanopy Group Section Assembly and Canopy GroupThis page Left Intentionally Blank Base Assembly USS Manifold and Main Burners Inch Main Burners Manifold and Main Burners 1 Inch Main Burners Only MM Main Burners Only Manifold and Main Burners 40mm Main Burners4B MM Main Burner, Electronic Ignition Only 4D MM Main Burner, Natural Gas, 2001-5000 Ft. USA Only MM Main Burners Only 4C MM Main Burner Manifold4D MM Main Burner, LP Gas, 2001-5000 Ft. USA Only 4D MM Main Burner, Natural Gas, 5001-9000 Ft. USA OnlyBurner Only 40mm Burner Only Pilot Burner, Honeywell Q327A1147 Pilot Burner, Honeywell Q348A1002 Jacket Assembly Jacket Assembly, CompletePage Jacket Vestibule Panel Water Trim Limit Control Flame Rollout Switch Transformer/Relay Assembly Intermittent Circulation OnlyBlocked Vent Switch Transformer Continuous and Gravity Circulation OnlyVent Damper Draft Hood CartonVent Reducer Service Record Service Record Service Record Lwco Location Wiring of Typical LwcoLimited Warranty