Burnham Series 2B manual Burner Only 40mm Burner Only

Page 38

*1" Burner Only

**40mm Burner Only

Key

Description

Part No.

 

 

 

 

Quantity

 

 

 

 

 

No.

202

202X

203

204

205

206

207

208

209

 

210

5. Pilot Burner and Gas Valve, 24-volt Continuous Ignition, Natural Gas (1 Inch and 40mm Main Burners)

 

5A

Pilot Burner, Honeywell Q350A1321

8236065

1

1

1

1

1

1

*1

---

---

 

---

Pilot Burner, Honeywell Q327A1006

8236022

---

---

---

---

---

---

**1

1

1

 

1

 

 

5B

Pilot Orifice, Honeywell 390686-22 .012"

Included

1

1

1

1

1

1

---

---

---

 

---

Pilot Orifice, Honeywell 388146AG .026"

with 5A

---

---

---

---

---

---

1

1

1

 

1

 

 

5C

Adptr, 1/4"OD x 1/4" NPT Included w/5A & 5E

8236109

2

2

2

2

2

2

2

2

2

 

2

5D

Pilot Tubing, 1/4" OD x 30" LG

8236122

1

1

1

1

1

1

1

---

---

 

---

Pilot Tubing, 1/4" OD x 40" LG

8236123

---

---

---

---

---

---

---

1

1

 

1

 

 

 

Gas Valve, Honeywell VR8200C3005

81660143

1*

1*

1*

1*

1*

1*

---

---

---

 

---

5E

Gas Valve, Honeywell VR8300C4027

81660154

---

---

---

---

---

---

1*

1*

1*

 

1*

Gas Valve, Honeywell VR8200C6065

100333-01

1**

1**

1**

1**

1**

1**

---

---

---

 

---

 

 

 

Gas Valve, Honeywell VR8300C4266

100334-01

---

---

---

---

---

---

1**

1**

1**

 

1**

5F

Thermocouple, 30", Honeywell Q309A

8236024

1

1

1

1

1

1

1

1

1

 

1

38

Image 38
Contents Series 2 model B Price $3.00Table of Contents Weight Do not drop boiler. Do not bump boiler jacket against floor ClearancesMinimum Clearances Boiler Piping Equivalent Length of FittingsSpecific Gravity Correction Factors for Natural Gas Page Page Do not use one vent damper to control two heating appliances Page Wiring Diagrams and Heat Anticipator Settings Page Safety Shutdown Sequence of Operation Page Sequence of Operation Normal Operation Wiring Schematic, Zone Valves II. Operating Instructions Top View of VR Gas Valves Instructions to PUT the Boiler in Operation Yellow LED Flame CodesGreen LED Status Codes Lighting Instructions Check GAS Input Rate to Boiler Check Pilot Burner FlameCheck Ignition System Safety SHUT-OFF Device Combustion Chamber BURN-OFFIII. Trouble Shooting IV. Service Burner 40mm Burner Pilot Burner LocationAvoid Breathing Fiber Particulates and Dust Repair Parts Section Assembly Gravity Circulation OnlySection Assembly and Canopy Group Canopy GroupThis page Left Intentionally Blank Base Assembly USS Manifold and Main Burners Inch Main Burners Manifold and Main Burners 1 Inch Main Burners Only 4B MM Main Burner, Electronic Ignition Only Manifold and Main Burners 40mm Main BurnersMM Main Burners Only 4D MM Main Burner, LP Gas, 2001-5000 Ft. USA Only MM Main Burners Only 4C MM Main Burner Manifold4D MM Main Burner, Natural Gas, 2001-5000 Ft. USA Only 4D MM Main Burner, Natural Gas, 5001-9000 Ft. USA OnlyBurner Only 40mm Burner Only Pilot Burner, Honeywell Q327A1147 Pilot Burner, Honeywell Q348A1002 Jacket Assembly, Complete Jacket AssemblyPage Jacket Vestibule Panel Water Trim Limit Control Blocked Vent Switch Transformer/Relay Assembly Intermittent Circulation OnlyFlame Rollout Switch Transformer Continuous and Gravity Circulation OnlyVent Reducer Draft Hood CartonVent Damper Service Record Service Record Service Record Wiring of Typical Lwco Lwco LocationLimited Warranty